Syaharussajali, Syaharussajali (2021) MODIFIKASI GEOMETRI DAN VARIASI MATERIAL NANO PELAPIS KANAL PEMISAHAN (ZnO DAN TiO2) µPAD MULTIKANAL. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.
Text
02311740000084-Undergraduate-thesis.pdf - Accepted Version Restricted to Repository staff only until 1 October 2023. Download (7MB) | Request a copy |
Abstract
Mikrofluida kertas multikanal adalah peranti alternatif yang dapat digunakan untuk pemisahan plasma darah secara simultan yang handal dan terjangkau. Pada penelitian ini dikembangkan peranti mikrofluida kertas multikanal yang diintegrasikan dengan partikel nano ZnO dan TiO2 melalui proses deposisi drop-casting pada zona separasinya serta modifikasi geometri yang dianalisis dengan menggunakan pendekatan Computational Fluid Dynamics (CFD). Geometri dianalisis dengan memvariasikan jumlah kanal, lebar kanal, dan panjang kanal zona pemisahan. Hasil simulasi yang telah tervalidasi pengukuran secara eksperimental menunjukkan bahwa waktu yang dibutuhkan untuk pemisahan plasma darah berbanding lurus dengan banyaknya jumlah kanal dan panjang kanal pemisahan. Akan tetapi, waktu pemisahan plasma darah ini berbanding terbalik dengan lebar kanal pemisahan. Hasil simulasi menunjukkan geometri dengan waktu pemisahan plasma tercepat diperoleh untuk jumlah kanal 4, lebar kanal 3 mm, dan panjang kanal 1 mm. Namun, hasil eksperimen mencatat geometri dengan pemisahan plasma darah yang baik untuk panjang kanal 3 mm dan lebar 1 mm dengan waktu pemisahan plasma darah sebesar 15,3 detik.
=================================================================================================
Multichannel microfluidic paper is an alternative device that can be used for reliable and affordable simultaneous separation of blood plasma. In this study, a multichannel paper-based microfluidic device was developed which was integrated with drop-casted ZnO and TiO2 nanoparticles and the geometries were modified and analyzed using the Computational Fluid Dynamics (CFD) approach. Geometry was modified by varying the number, the width, and the length of the channel in separation zone. The results of simulations after validation with the experimental data reveals that the time required for the blood plasma separation is proportional to the number of channels and the length of the separation channels. However, it is inversely proportional to the width of the separation channel. The simulation results suggest that the optimum geometry of microfluidic paper should bear 4 separation channels with 3 mm wide and 1 mm long. However, the experimental results show that the the best geometry of the separation channel should be 3 mm long and 1 mm wide to be able to separate blood plasma in 15.3 seconds.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | µPAD multikanal, TiO2, ZnO, CFD, Waktu pemisahan Multichannel µPAD, TiO2, ZnO, CFD, Separation time |
Subjects: | T Technology > TP Chemical technology > TP159.M4 Membranes (Technology) T Technology > TP Chemical technology > TP248 Nanogels. Nanoparticles. |
Divisions: | Faculty of Industrial Technology and Systems Engineering (INDSYS) > Physics Engineering > 30201-(S1) Undergraduate Thesis |
Depositing User: | syaharussajali syaharussajali |
Date Deposited: | 20 Aug 2021 07:28 |
Last Modified: | 20 Aug 2021 07:28 |
URI: | http://repository.its.ac.id/id/eprint/88028 |
Actions (login required)
View Item |