Zaroh, Leony Nikmatus (2021) Pengembangan Aplikasi Berbasi Desktop untuk Meningkatkan Efisiensi Waktu Proses Kalibrasi Emergency Ventilator PM-01 Menggunakan Metode Waterfall. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.
Text
10311710000018-Undergraduate_Thesis.pdf - Accepted Version Restricted to Repository staff only until 1 October 2023. Download (4MB) | Request a copy |
Abstract
Proses kalibrasi ventilator dilakukan untuk memastikan nilai dari pembacaan sensor pada PM-01 Emergency Ventilator dan Gas Flow Analyzer (kalibrator) menunjukkan hasil yang sesuai. Demi menunjang proses kalibrasi, terdapat aplikasi kalibrasi yang digunakan untuk memonitor serta mengambil data kalibrasi yang dibaca oleh ventilator dan kalibrator agar hasil kalibrasi dapat didokumentasikan dengan baik. Namun disisi lain terdapat kendala pada aplikasi kalibrasi yang disebabkan oleh adanya tambahan pada proses kalibrasi dan belum dintegrasikan terhadap aplikasi kalibrasi dan menyebabkan proses kalibrasi berjalan kurang efisien. Maka dari itu direncanakan pengembangan pada aplikasi kalibrasi dengan cara penambahan fitur (1) fitur monitoring bar kalibrasi (2) fitur pengaturan parameter kalibrasi (3) fitur pengontrolan ventilator (4) fitur monitoring status pengontrolan (5) fitur setting data respon (6) fitur pengambilan data otomatis. Hasil pengujian dari aplikasi kalibrasi yakni fungsionalitasnya dapat berjalan dengan presentase 94.13% dan hasil efisiensi proses kalibrasi sebesar 23.6% dengan nilai keakuratan sebesar 83.92%.
=====================================================================================================
The ventilator calibration process is carried out to ensure the value of the sensor readings on the PM-01 Emergency Ventilator and Gas Flow Analyzer (calibrator) shows the appropriate results. In order to support the calibration process, there is a calibration application that is used to monitor and retrieve calibration data that is read by the ventilator and calibrator so that the calibration results can be properly documented. But on the other hand there are problems in the calibration application caused by the addition of the calibration process and it has not been integrated into the calibration application and causes the calibration process to run inefficiently. Therefore, it is planned to develop a calibration application by adding features (1) calibration bar monitoring feature (2) calibration parameter setting feature (3) ventilator control feature (4) controlling status monitoring feature (5) setting data respon feature (6) feature automatic data retrieval. The test results of the calibration application are that the functionality can run with a percentage of 94.13% and the results of the calibration process efficiency are 23.6% with an accuracy value of 83.92%.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | Kata kunci— Aplikasi, Kalibrasi, Ventilator, Fitur, Fungsionalotas, Efisiensi ========================================================= Keywords — Application, Calibration, Ventilator, Features, Functionality, Efficiency |
Subjects: | T Technology > T Technology (General) > T58.5 Information technology. IT--Auditing T Technology > T Technology (General) > T58.6 Management information systems |
Divisions: | Faculty of Vocational > 36304-Automation Electronic Engineering |
Depositing User: | Leony Nikmatus Zaroh |
Date Deposited: | 19 Aug 2021 22:06 |
Last Modified: | 19 Aug 2021 22:06 |
URI: | http://repository.its.ac.id/id/eprint/88687 |