Mahardika, Bachtiar (2021) Analisis Perbandingan Steel Pipe Sheet Pile Dan HZ/AZ Combined Wall Pada Perkuatan Struktur Dermaga Terminal Berlian Akibat Peningkatan Kapasitas Sebesar 50.000 DWT. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.
Preview |
Text
10111710013081-Undergraduate_Thesis.pdf - Accepted Version Download (7MB) | Preview |
Abstract
Proyek Pekerjaan Perkuatan Struktur Dermaga Terminal Berlian di Tanjung Perak Surabaya merupakan perkuatan struktur dinding kaison akibat dari usia dermaga yang sudah lebih dari 80 tahun sekaligus peningkatan kapasitas dermaga dari 15.000 menjadi 50.000 DWT dengan menambahkan struktur baru mengelilingi dermaga menggunakan Steel Pipe Sheet Pile dengan panjang 32 meter.
Realisasi pengecoran mengalami kebocoran pada sambungannya dari beberapa titik tinjau pada satu titik pengecorannya bervariasi antara 0,35 m3 dan 0,7 m3 dari yang seharusnya sebesar 0,3 m3 (Data Proyek, 2020). Oleh karena itu, penulis mengusulkan untuk mendesain alternatif perkuatan Dermaga Terminal Berlian dengan HZ/AZ Combined Wall. Model ini tidak perlu melakukan pengecoran pada sambungannya dan memiliki dimensi penampang yang lebar juga dan relatif tipis sehingga dapat menghemat volume beton maupun besi yang digunakan.
Hasil penelitian ini bahwa HZ/AZ Combined Wall dengan panjang 32 meter pada kondisi drained menghasilkan section modulus sebesar 4339 cm3/m masih lebih kecil dari kapasitasnya sebesar 5600 cm3/m dan displacement sebesar 5,82 cm, sedangkan Steel Pipe Sheet Pile menghasilkan section modulus sebesar 3060 cm3/m masih lebih kecil dari kapasitasnya sebesar 9110 cm3/m dan displacement sebesar 6,2 cm. Jadi, HZ/AZ Combined Wall dari aspek kekuatan struktur telah memenuhi sehingga selanjutnya dapat dipertimbangkan aspek lain maupun penggunaannya.
================================================================================================
The Work Project of Strengthening Pier Structure of Terminal Berlian on Tanjung Perak Surabaya is a process of strengthening caisson wall as a result of the pier’s age which is more than 80 years old as well as increasing capacity of Terminal Berlian’s Pier from 15.000 to 50.000 DWT by adding a new structure surrounding the pier at the seaside using Steel Pipe Sheet Pile having a width of 32 meters.
The casting realization has a leak in the connector from several viewpoints on one of the casting points, the casting is varied between 0,35 m3 and 0,7 m3 while it is supposed to be 0,3 m3 (Project Data, 2020). Therefore, the author proposes to design an alternative way to strengthen Terminal Berlian’s Pier using the HZ/AZ Combined Wall. This model does not need to do casting to the connector, has a wide surface dimension, and is relatively thin hence the volume of concrete and steel that is used can be reduced.
The result of this study shows that HZ/AZ Combined Wall having a length of 32 meter on drained condition resulting modulus section in the amount of 4339 cm3/m is still smaller than the capacity which is at 5600 cm3/m and displacement by 5,82 cm, while Steel Pipe Sheet Pile resulting modulus section in the amount of 3060 cm3/m is still smaller than the capacity which is at 9110 cm3/m and displacement by 6,2 cm. In conclusion, HZ/AZ Combined Wall has satisfy the needs from the aspect of structure’s strength so that furthermore the other aspects as well as the utilization can be considered.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | Pier, Dermaga, Steel Pipe Sheet Pile, HZ/AZ Combined Wall |
Subjects: | T Technology > TA Engineering (General). Civil engineering (General) > TA760+ Retaining walls |
Divisions: | Faculty of Vocational > Civil Infrastructure Engineering (D4) |
Depositing User: | Bachtiar Mahardika |
Date Deposited: | 27 Aug 2021 13:52 |
Last Modified: | 10 Jul 2024 08:44 |
URI: | http://repository.its.ac.id/id/eprint/90231 |