Prakoso, Devian Bayu (2021) Penerapan Metode Moving Average Sebagai Noise Filter pada Gas Flow Analyzer. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.
Text
10311710000043_Undergraduate_Thesis.pdf - Accepted Version Restricted to Repository staff only until 1 October 2023. Download (1MB) | Request a copy |
Abstract
Sejak pertama kalinya Virus Corona muncul di Wuhan, China pada akhir Desember 2019 dan menyebar diseluruh belahan dunia, WHO mendorong perusahaan yang bergerak dibidang peralatan kesehatan salah satunya adalah ventilator untuk mempercepat produksi berbagai jenis ventilator yang ada dalam rangka memenuhi kebutuhan peningkatan kasus COVID-19. Dengan diproduksinya mesin ventilator, diperlukan suatu alat yang bernama Gas Flow Analyzer yang digunakan untuk menguji dan mengkalibrasi ventilator. Untuk mendapatkan hasil pengukuran yang presisi dan akurat dalam proses pengujian dan kalibrasi, diterapkan suatu metode yang bernama Moving Average yang bertindak sebagai Noise Filter pada sensor-sensor yang terpasang pada Gas Flow Analyzer. Dari hasil pengujian pengukuran kinerja alat, didapatkan rata-rata error yang didapat sekitar 2,5% dan nilai akurasi menunjukan diatas 95%, sehingga alat ini dapat dinyatakan baik dan layak untuk digunakan.
===================================================================================================
Since the Corona Virus first appeared in Wuhan, China at the end of December 2019 and spread throughout the world, WHO has encouraged companies engaged in health equipment, one of which is ventilators to encourage the production of various types of ventilators in order to meet the needs of increasing COVID-19 cases. With the production of a ventilator machine, a tool called a Gas Flow Analyzer is needed which is used to test and calibrate the ventilator. To get precise and accurate measurement results in the testing and calibration process, a method called Moving Average acts as a Noise Filter on the sensors installed on the Gas Flow Analyzer. From the test results above the performance of the tool, the average error obtained is about 2,5% and the accuracy value shows 95%, so that this tool can be declared good and feasible to use.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | COVID-19, Gas Flow Analyzer, Moving Average, Ventilator, COVID-19, Gas Flow Analyzer, Moving Average, Ventilator |
Subjects: | T Technology > T Technology (General) > T57.5 Data Processing |
Divisions: | Faculty of Vocational > 36304-Automation Electronic Engineering |
Depositing User: | Devian Bayu Prakoso |
Date Deposited: | 02 Sep 2021 03:26 |
Last Modified: | 02 Sep 2021 03:26 |
URI: | http://repository.its.ac.id/id/eprint/91631 |