Analisa Pemodelan Dan Simulasi Mekanisme Electromagnetic Vibration Absorber Terhadap Reduksi Getaran Serta Energi Listrik Bangkitan

Andreana, Glory Mega (2022) Analisa Pemodelan Dan Simulasi Mekanisme Electromagnetic Vibration Absorber Terhadap Reduksi Getaran Serta Energi Listrik Bangkitan. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 02111440000005-Undergraduate_Thesis.pdf]
Preview
Text
02111440000005-Undergraduate_Thesis.pdf - Accepted Version

Download (11MB) | Preview

Abstract

Fenomena getaran pada mesin-mesin di industri dapat mengakibatkan gangguan pada komponen mesin serta membuat umur pakai mesin lebih pendek. Salah satu cara untuk mengurangi getaran berlebih tersebut adalah dengan Electromagnetic Vibration Absorber (EMVA). Energi getaran yang diserap pada proses reduksi getaran dengan DVA dapat dimanfaatkan lagi menjadi energi listrik. Pemanfaatan energi tersbut dapat dilakukan oleh komponen elektrik yaitu hasil induksi antara magnet dengan kumparan. Dengan menggunakan komponen tersebut pada sistem EMVA, maka energi getaran akan direduksi sekaligus dapat dimanfaatkan menjadi energi listrik.
Pembuatan tugas akhir kali ini dilakukan pada skala laboratorium mengenai studi eksperimental “EMVA” electromagnetic vibration absorber yaitu mekanisme vibration absorber sekaligus juga sebagai energy harvester dengan material magnet dan kumparan yang ditempatkan pada sistem utama. Sistem utama merupakan sistem yang terdiri dari massa yang ditopang empat buah pegas dengan nilai konstanta pegas yang sama pada sisi kanan dan dua konstanta pegas lain yang sama di sisi kiri kemudian dikenai gaya eksitasi yang bersumber dari massa eksentris motor DC sehingga sistem dapat bergetar secara translasi dan rotasi. EMVA yang dirancang nantinya dapat mereduksi getaran translasi dan rotasi sistem utama sekaligus menghasilkan listrik. Variasi-variasi yang dilakukan pada penilitian ini merupakan variasi rasio massa absorber terhadap massa sistem utama sebesar 1/40; 1/20; 3/40 serta posisi penempatan EMVA pada sistem utama yaitu pada sembilan titik berbeda.
Dari penelitian yang dilakukan, didapatkan hasil reduksi getaran sistem utama yang optimal adalah dengan kombinasi massa absorber sebesar 1:20 dan posisi terjauh dari pusat massa sistem utama namun terdekat dengan koefisien pegas sistem utama terkecil. Presentase reduksi getaran translasi sebesar 98,76% untuk rata-rata percepatan translasi, 97,64% untuk rata-rata percepatan rolling, dan 98,56% untuk rata-rata percepatan pitching pada frekuensi natural 39,5954 rad/s dan amplitude 0,02 m.
=================================================================================================
The phenomenon of vibration on industrial machines can cause disturbances to machine components and shorten the life of the machine. One way to reduce excessive vibration is with an Electromagnetic Vibration Absorber (EMVA). Vibration energy absorbed in the vibration reduction process with DVA can be reused into electrical energy. The utilization of this energy can be done by electrical components, namely the result of induction between the magnet and the coil. By using these components in the EMVA system, the vibration energy will be reduced at the same time can be used as electrical energy.
The making of this final project is carried out on a laboratory scale regarding the experimental study of "EMVA" electromagnetic vibration absorber, namely the vibration absorber mechanism as well as an energy harvester with magnetic and coils placed in the main system. The main system is a system consisting of a mass supported by four springs with the different value of spring on each side which are then subjected to an excitation force sourced from the eccentric mass of the DC motor so that the system can vibrate translationally and rotationally. The EMVA designed later can reduce translational and rotational vibrations of the main system while generating electricity. The variations carried out in this study are variations in the ratio of the mass of the absorber to the mass of the main system of 1/40; 1/20; 3/40 and the position of EMVA placement in the main system, namely at nine different points.
From the research has been conducted, it was found that the optimal main system vibration reduction result is the combination of the absorber mass of 1:20 and the position is farthest from the centre of mass of the main system but closest to the smallest main system spring coefficient. The percentage of translational vibration reduction is 98.76% for the average translational acceleration, 97.64% for the average rolling acceleration, and 98.56% for the average pitching acceleration at a natural frequency of 39.5954 rad/s and an amplitude of 0,02 m.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: vibration, frequency, amplitude, electromagnetic vibration absorber, electrical energy, coil, magnet, getaran, frekuensi, amplitudo, electromagnetic vibration absorber, energi listrik, kumparan, magnet.
Subjects: T Technology > TA Engineering (General). Civil engineering (General) > TA355 Vibration.
T Technology > TJ Mechanical engineering and machinery > TJ808 Renewable energy sources. Energy harvesting.
Divisions: Faculty of Industrial Technology and Systems Engineering (INDSYS) > Mechanical Engineering > 21201-(S1) Undergraduate Thesis
Depositing User: Glory Mega Andreana
Date Deposited: 17 Feb 2022 04:31
Last Modified: 07 Oct 2024 06:33
URI: http://repository.its.ac.id/id/eprint/94066

Actions (login required)

View Item View Item