Modifikasi Gedung Airlangga Dormitory Menggunakan Sistem Base Isolator Tipe High Damping Rubber Bearing (HDRB)

Atsany, Alfya Natasya Devi (2022) Modifikasi Gedung Airlangga Dormitory Menggunakan Sistem Base Isolator Tipe High Damping Rubber Bearing (HDRB). Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 03111840000004-Undergraduate_Thesis.pdf] Text
03111840000004-Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 October 2024.

Download (18MB) | Request a copy

Abstract

Indonesia merupakan salah satu negara yang sering mengalami gempa vulkanik ataupun gempa tektonik. Berdasarkan data BMKG tercatat pada tahun 2020, telah terjadi 8.264 kejadian gempa di seluruh wilayah Indonesia dan sekitarnya. Salah satu daerah yang masuk pada daerah rawan gempa adalah Surabaya. Sedangkan kondisidi Indonesia masih jarang dengan mempertimbangkan perencanaan bangunan tahan gempa, dengan kondisi konstruksi banyak kesalahan dalam memilih konfigurasi struktur, jenis material yang digunakan, serta sistem strukturdari bangunan yang mengakibatkan kerusakan bahkan kehancuran secara menyeluruh dari struktur bangunan tersebut. Perencanaan struktur bangunanumumnya menggunakan metode linear dinamik (respons spectrum) dengan kemampuan nominal struktur harus sama atau lebih besar dari nilai total beban terfaktor. Sehingga pada perencanaan ini, struktur bangunan tidak memperlihatkan kondisi struktur bangunan pasca elastis akibat beban gempa. Maka dari itu pada pengerjaan tugas akhir menggunakan salah satu metoda untuk menganalisa menganalisa kekuatan struktur bangunan dalam kondisi pasca elastic akibat beban gempamenggunakan analisis non-linear time history.Pada modifikasi ini menggunakan base isolator yaitu high damping rubber bearing(HDRB). Dengan adanya konsep base isolator diharapkanstruktur atas mengalami peningkatkan kinerja dengan mengurangi tingkat kerusakan struktur akibat beban gempa.Banyak jenis laminated rubber yang dapat digunakan salah satunya adalahHigh Damping Rubber Bearing(HDRB), dengan material yang terbuat dari campuran senyawa karet dengan nilai rasio redaman yang tinggi. Dengan penggunaan base isolator,struktur dapat menahan beban angin dan beban gempa tanpa mengalami deformasi secara signifikan. Sehingga struktur mengalamipeningkatan eksitasi gempa yang berakibat pada peningkatandeformasilateraldan modulus geser dari rubber akan menurun,menghasilkan sistem isolatoryang efektif dan efisien.Pada pengerjaan tugas akhir, data-data yang dibutuhkan adalah data sekunder yang telah di dapatkan penulis dari Universitas Airlangga yang terdiri dari gambar teknik bangunan, data tanah yang didapatkan dari Laboratorium Mekanikal Tanah dan Batuan, Institut Teknologi Sepuluh Nopember. Dengan menganalisa menggunakan metode Nonlinier Time history Analysisdiperlukanadanyadata percepatan gempa yang dianalisisantara lain Coyote Lake Dam, Kobe, Lexingt, Miyagi, NewHall, Tabas dan Yermo.Selama pengerjaandan penyelesaian analisisstruktur bagunan dibantu dengan programbantu SAP2000.Pada perhitungan struktur bangunan SRPMK (Struktur Rangka Pemikul Momen Khusus) digunakan faktor untuk bangunan fix basedsebesar R = 8 danuntuk struktur base isolateddigunakan SRPMB (Struktur Rangka Pemikul MomenBiasa) dengan R = 2. Hasil dari analisis untuk struktur fix based didapatkan modal 1 sebesar 1,37 s dengan nilai simpang antar lantai pada tingkat atap arah X sebesar 34,86 mm dan arah Y sebesar 31,28 mm. Dengan bentuk bangunan yang tidak simetris sehingga adanya ketidakberaturan sudut dalam dikarekan bangunan arah Y sebesar 1,60 m.Pada struktur menggunakan base isolated didapatkan modal 1 sebesar 3,32 s dengan nilai simpang antar lantai pada tingkat atap arah X 116,22 mm dan arah Y 128,99 mm. Dengan batas maksimum 200 mm sesuai dengan batas material HDRB yang digunakan.Untuk pendesaian bangunan menggunakan respons spectrum dibantu dengan validasi dengan analisa time history agar bangunan memiliki ductilitas yang baik dan gerak bangunan lebih rigid atau rigid deformation.
===========================================================================================================================
Indonesia is one of the countries that often experience volcanic earthquakes or tectonic earthquakes. Based on BMKG data recorded in 2020, there have been 8,264 earthquakes throughout Indonesiaand its surroundings. One of the areas that are included in the earthquake-prone area in Surabaya. While conditions in Indonesia are still rare considering earthquake-resistant building planning, with construction conditions, there are many mistakes in choosing the configuration of the structure, the type of material used, and the structural system of the building, which results in damage and even destruction of the building structure. Building structure planning generally uses a dynamic linear method (response spectrum) with the nominal capability of the structure must be equal to or greater than the total factored load value. So in this planning, the building structure does not show the condition of the post-elastic building structure due to earthquake loads. Therefore, in the final project, one method is used to analyze the strength of the building structure in post-elastic conditions due to earthquake loads using non-linear time history analysis.This modification uses base isolation, namely high dampingrubber bearing (HDRB). With the concept of a base isolation, it is expected that the superstructure will experience an increase in performance by reducing the structural damage due to earthquake loads. Many types of laminated rubber can be used, one of which is High Damping Rubber Bearing (HDRB), a material made of a mixture of rubber compounds with a high damping ratio value. Using base isolation, the structure can withstand wind and earthquake loads without significant deformation. So that the structure experiences an increase in earthquake excitation, which increases lateral deformation, and the shear modulus of the rubber will decrease, resulting in an effective and efficient isolationsystem.In the final project, the data needed is secondary data obtained by the contractorfrom Airlangga’s DormitoryUniversity, which consists of building engineering drawings, and soil data obtained from the Soil and Rock Mechanical Laboratory, Institut Teknologi Sepuluh Nopember. By analyzing using the nonlinear time history analysis method, it is necessary to have earthquake acceleration data analyzed, including Coyote Lake Dam, Kobe, Lexingt, Miyagi, Newhall, Tabas and Yermo, during the construction and completion of the structural analysis of the building, assisted by the SAP2000 program.In calculating the structure of the SRPMK (Special Moment Resisting Frame Structure) building, the factor for the fixed-based building is R = 8. For the base-isolated structure, the SRPMB (Ordinary Moment Resisting Frame Structure) is used with R = 2. The analysis results for the fixed-based structure are that capital 1 is 1.37 secwith the intersection between floors at the roof level in the X direction of 34.86 mm and the Y direction of 31.28 mm with the shape of the building that is not symmetrical so that there is an irregularity in the interior angle due to the Y-direction building of 1.60 m. In the structure using an isolated base, capital 1 is 3.32 s with the value of the intersection between floors at the roof level in the X direction of 116.22 mm and the Y direction of 128.99 mm. With a maximum limit of 200 mm by the limits of the HDRB material used. For the design of buildings using a response spectrum assisted by validation with time history analysis, the building has good ductility and the building motion is more rigid or rigid deformation.

Item Type: Thesis (Other)
Additional Information: RSS 624.189 4 Ats m-1 2022
Uncontrolled Keywords: Struktur Bangunan Tahan Gempa, Base Isolator, Fix Based, Base Isolated, HDRB, Earthquake Resistant Building Structure, Base Isolation
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
T Technology > TA Engineering (General). Civil engineering (General) > TA658 Structural design
Divisions: Faculty of Civil, Planning, and Geo Engineering (CIVPLAN) > Civil Engineering > 22201-(S1) Undergraduate Thesis
Depositing User: Anis Wulandari
Date Deposited: 03 Nov 2022 01:42
Last Modified: 03 Nov 2022 01:42
URI: http://repository.its.ac.id/id/eprint/95050