Abstract

Analisis kestabilan transien memainkan peranan penting dalam menjaga reliabilitasdan kontinuitas sistem terutama ketika menghadapi gangguan besar seperti hubung singkat. Permasalahan kestabilan transien merupakan tantangan yang luar biasa ketika sistem proteksi harus bekerja cepat untuk mengisolasi gangguan hubung singkat. Karena apabila gangguan terlambat dihilangkan dan melebihi nilai Critical Clearing Time(CCT),maka dapat mengakibatkan sistem tidak stabil.Oleh karena itu CCT menjadi aspek penting untuk menentukan waktu pemutusan gangguan maksimum bagi sistem proteksi untuk mengisolasi gangguan dan menjaga sistem tetap stabil. Hingga kini, telah terdapat beberapa alternatif metode yang digunakan untuk meningkatkan kestabilan sistem melalui peningkatan nilai CCT. Salah satunya dengan menggunakan Superconducting Fault Current Limiter (SFCL). Karakteristik SFCL yang dapat membuat nilai impedansi menjadi tinggi ketika terjadi gangguan dan menjadi rendah ketika dalam keadaan normal dalam waktu transisi yang sangat dapat digunakan untuk meningkatkan nilai CCTpada sistem. Dalam penelitian ini, pengaplikasian SFCL pada sistem diuji dengan menggunakan metode critical trajectory karena memiliki iterasi yang sedikit dankomputasi yang cepat. Hasil yang diperoleh akan divalidasi kembali dengan menggunakan metodeTime Domain Simulation(TDS). Pengujian akan dilakukan untuk mengetahui efektifitas SFCL dalam meningkatkan nilai CCT dengan menggunakan sistem IEEE3-machine9-bus, IEEE6-machine30-bus, dan IEEE 7-machine57-bus.Hasil penelitian menunjukkan bahwa pengaplikasian SFCL pada saluran dapat meningkatkan kestabilan pada sistem seiring dengan naiknya nilai CCT pada sistem. Kenaikan nilai CCT yang diperoleh akan bergantung pada konfigurasi lokasi dan kapasitas SFCL yang terpasang pada sistem tersebut.Kenaikan nilai CCT tertinggi terjadi ketika SFCl dipasang pada saluran dekat generator.
===========================================================================================================================
Transient stability analysis plays an important role in maintaining the reliability and continuity of thepowersystem. The transient stabilityissueis a tremendous challenge when the protection system must work quickly to isolate thefaults. Because if it exceeds the Critical Clearing Time (CCT) value, it can lead to system unstable and blackout. Therefore, the CCTbecomes important in determiningthe maximum clearingtime for the protection system to isolate the fault and keep the system remain stable.Several alternative methods have beenused to improve system stability by increasing the CCTvalue. One of them is using the Superconducting Fault Current Limiter (SFCL). The characteristics of SFCLcan make the impedance value high when a faultoccurs and become very low under normal conditions in the transition time,increasingthe CCTvalue in the system. In this study, the application of SFCLto the system was tested using the critical trajectorymethod because it has few iterations and fast computation. The results obtained will be validated again using the Time Domain Simulation (TDS) method.The effectiveness of SFCLin CCTimprovementis validatedusing the IEEE 3-machine9-bus, IEEE 6-machine30-bus, and IEEE 7-machine57-bus systemsas a benchmark. Therefore, the results showed that SFCLutilizationcouldincrease the system's stabilityand increasethe CCTvalue in the system. The CCTvalue will depend on theSFCLlocation andcapacity installed on the system. The highest increase in CCToccurred when SFCl was installed in the line near the generator.

Item Type: Thesis (Masters)
Additional Information: RTE 621.319 Mah p-1 2022
Uncontrolled Keywords: critical clearing time, critical trajectory, kestabilan transien, superconducting fault current limiter, time domain simulation, transient stability
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK2861 Electric relays