Abstract

3D Origami microfluidic paper-based analytical device (μPAD) didesain dengan tujuan untuk menghindari terjadinya campuran antar reagen pada zona deteksi. Tantangan pengembangan arsitektur μPAD terletak pada proses separasi yang efektif, efisien, range pengukuran yang lebar dan sensitivitas yang tinggi. Pada penelitian ini dikembangkan 3D Origami μPAD yang terdiri dari 4 lapisan. Untuk meningkatkan sensititvitas dan range pengukuran senyawa neurotransmitter yaitu glutamat, maka zona deteksi dimodifikasi dengan nanokomposit Grafena/Pd dan Grafena/Pt yang disintesis secara hidrotermal. 3D Origami μPAD yang telah berhasil difabrikasi meliputi lapisan I untuk penetesan reagen dan sampel, lapisan II sebagai kanal untuk aliran fluida, lapisan III merupakan lapisan tambahan untuk menghindari campuran reagen, dan lapisan IV sebagai zona kuantifikasi neurotransmitter. Modifikasi Grafena/Pd dan Grafena/Pt pada zona deteksi berturut-turut mengakibatkan karakteristik permukaan menjadi lebih hidrofobik dan hidrofilik. Karakteristik dinamik sensor μPAD termodifikasi Grafena/Pt menghasilkan respon steady yang cepat dan stabil dibandingkan μPAD yang termodifikasi Grafena/Pd. Deteksi glutamat terbaik didapatkan pada variasi Pd/Pt 5 mM dalam nanokomposit yang menghasilkan linieritas (R2 = 0.77) dan sensitivitas -7.24 mM-1 untuk Grafena/Pd, sedangkan penambahan Grafena/Pt menghasilkan R2 = 0.87 dan sensitivitas 22.99 mM-1
==================================================================================================================================
The 3D Origami microfluidic paper-based analytical device (μPAD) is designed with the aim at avoiding mixing between reagents in the detection zone. The challenge of developing the μPAD architecture lies in an effective, efficient separation process, a wide measurement range and high sensitivity. In this study, 3D Origami μPAD was developed which consists of 4 layers. To increase the sensitivity and measurement range of neurotransmitter including glutamate, the detection zone was modified with hydrothermally synthesized Graphene/Pd and Graphene/Pt nanocomposites. The 3D Origami μPAD that has been successfully fabricated includes layer I for reagent and sample droplet, layer II as channels for fluid flow, layer III is an additional layer to avoid reagent mixture, and layer IV for neurotransmitter quantification zone. Modification of Graphene/Pd and Graphene/Pt in the detection zone results in a more hydrophobic and hydrophilic surface characteristic, respectively. The dynamic characteristics of the Graphene/Pt modified μPAD sensor yields a fast and stable steady-state response compared to the Graphene/Pd modified μPAD. The best glutamate detection was found in the 5 mM Pd/Pt variation in the nanocomposite which resulted in linearity (R2 = 0.77) and sensitivity of -7.24 mM-1 for Graphene/Pd, while the addition of Graphene/Pt resulted in R2 = 0.87 and sensitivity 22.99 mM-1

Item Type: Thesis (Other)
Additional Information: RSF 621.381 536 Jov d-1 2022
Uncontrolled Keywords: Mikrofluida, Sensitivitas, Nanokomposit, Katalis
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK7871.674 Detectors. Sensors