Modifikasi Perencanaan Struktur Gedung Apartemen Alessandro Vittorio Tower A Surabaya Dengan Sistem Steel Plate Shear Wall (SPSW)

Alfarisi, Farel Muhamad (2023) Modifikasi Perencanaan Struktur Gedung Apartemen Alessandro Vittorio Tower A Surabaya Dengan Sistem Steel Plate Shear Wall (SPSW). Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 03111940000108-Undergraduate_Thesis.pdf] Text
03111940000108-Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 April 2025.

Download (20MB) | Request a copy

Abstract

Bencana gempa adalah salah satu bencana yang sangat merugikan bagi Indonesia baik dari sisi infrastruktur, jiwa,dan ekonomi. Ditambah lagi dengan lokasi Indonesia yang berada di cincin api dan titik pertemuan tiga lempeng tektonik aktif. Akibatnya, resiko gempa di Indonesia cukup besar. Indonesia juga diprediksi akan mengalami gempa besar di masa yang akan datang. Sebagai contoh adalah gempa Megathrust dengan perkiraan besar gempa, yaitu 8,9 Skala Ricter. Oleh Karena itu, bangunan-bangunan di Indonesia harus didesain sebagai bangunan tahan gempa. Salah satu solusi untuk membangun bangunan tahan gempa adalah penggunaan sistem pengekang gaya lateral seperti dinding geser pelat baja (Steel Plate Shear Wall / SPSW). Selain dapat membantu gedung dalam menahan gaya lateral gempa, sistem ini juga dapat memberikan daktilitas tinggi dengan drift dan displacement yang rendah bila dibandingkan dengan sistem pengekang lateral lainnya. Bahkan, sistem ini dapat membuat desain bangunan lebih ekonomis karena dimungkinkan adanya reduksi dimensi elemen struktur serta ketebalan dinding pelat yang tipis. Pembangunan Gedung Apartemen Alessandro Vittorio Tower A Surabaya dengan jumlah lantai 26 di Surabaya akan dimodifikasi dengan sistem struktur Dinding Geser Pelat Baja. Peraturan yang akan digunakan pada perancangan modifikasi antara lain adalah SNI 1726:2019, SNI 1727:2020, SNI 1729:2020, SNI 7860:2020, SNI 7972:2020 dan SNI 2847:2019. Selain itu, hasil dari perencanaan modifikasi gedung ini akan dituangkan dalam bentuk gambar teknik. Diharapkan modifikasi ini dapat meningkatkan daktilitas bangunan dan ketahanan bangunan terhadap gaya gempa yang lebih baik. Dari hasil analisis yang telah dilakukan, diperoleh hasil sebagai berikut: pelat lantai podium, tower, dan atap memiliki ketebalan 11 cm; balok induk menggunakan profil WF 500x200x11x19; profil kolom lantai 1 – 6 adalah CFT 600x600x40; profil kolom lantai 7 – 20 adalah CFT 550x550x36; profil kolom lantai 21 – atap adalah CFT 500x500x36; ketebalan SPSW yang direncanakan adalah 4 mm, 3 mm, dan 2 mm; profil horizontal boundary element adalah (HBE) adalah WF 600x300x12x20; profil vertical boundary element (VBE) adalah CFT 850x850x60; sambungan baut menggunakan mutu A325 dan A490; sambungan las menggunakan mutu E70xx dan E90xx; pondasi tiang pancang direncanakan dengan diameter 60 cm; pile cap dengan dimensi 2,4 x 2,4 x 1,5; dan sloof dengan dimensi 35 x 50 cm.
=====================================================================================================================================
Earthquake is one of the disasters that is highly harmful for Indonesia’s infrastructure, population, and economy. Moreover, it is worsened by Indonesia’s location which is passed by the pacific ring of fire and is the meeting point of three active tectonic plates. Hence, Indonesia’s earthquake risks are quite big. Indonesia is also predicted to have large earthquakes in the upcoming future. For example, the Megathrust earthquake potential with the strength of 8,9 in the Richter scale. Because of that, buildings in Indonesia needs to be designed as earthquake resistant buildings. One solution to build earthquake resistant buildings is by utilizing lateral force resisting system such as Steel Plate Shear Wall. Besides supporting the building structure towards lateral force of earthquake, this system also gives a high ductility with low drift and displacement compared to the other lateral systems. In addition, this system also can make the design more economics because of the element dimension reduction ability and using thin plate. The building of Alessandro Vittorio Apartment Building A Tower Surabaya with its 26 stories in Surabaya will be modified by Steel Plate Shear Wall System Structure. The used code of this design modification are SNI 1726:2019, SNI 1727:2020, SNI 1729:2020, SNI 7860:2020, SNI 7972:2020 and SNI 2847:2019. Furthermore, output of this building design modification will be delivered in the form of technical drawing. The use of this system is expected to be able to increase the ductility and earthquake resistance of buildings. Based on the result of the analysis that has been carried out, the planning results are obtained as follows: slab of podium, tower, and roof floor has a thickness of 11 cm; main beam uses WF 500x200x11x19 section; column section of floors 1 – 6 are CFT 600x600x40; column section of floors 7 – 20 are CFT 550x550x36; column section of floors 21 – roof are CFT 500x500x36; planned SPSW thickness are 4 mm, 3 mm, and 2 mm; horizontal boundary element (HBE) section is WF 600x300x12x20; vertical boundary element (VBE) section is CFT 850x850x60; bolt connection uses grades A325 and A490; weld connection uses grades E70xx and E90xx; pile foundation is planned with 60 cm diameter dimension; pile cap dimension is 2,4 x 2,4 x 1,5 m; and sloof dimension is 35 x 50 cm

Item Type: Thesis (Other)
Uncontrolled Keywords: Gempa, Bangunan Tahan Gempa, Sistem Pengekang Gaya Lateral, Dinding Geser Pelat Baja, Earthquake, Earthquake Resistance Building, Lateral-Force Resisting System, Steel Plate Shear Wall
Subjects: T Technology > TH Building construction
T Technology > TH Building construction > TH1095 Earthquakes and building
T Technology > TH Building construction > TH2247 Shear walls--Materials
Divisions: Faculty of Civil, Planning, and Geo Engineering (CIVPLAN) > Civil Engineering > 22201-(S1) Undergraduate Thesis
Depositing User: Farel Muhamad Alfarisi
Date Deposited: 31 Jan 2023 01:57
Last Modified: 31 Jan 2023 01:57
URI: http://repository.its.ac.id/id/eprint/95842

Actions (login required)

View Item View Item