Pengaruh Penggunaan Air Purifier Dengan Kombinasi Ventilasi Dan AC Dalam Menurunkan PM Di Ruang Kelas - Analisis Eksperimen Dan Numerik

Kamilia, Nadinda Aisyah (2023) Pengaruh Penggunaan Air Purifier Dengan Kombinasi Ventilasi Dan AC Dalam Menurunkan PM Di Ruang Kelas - Analisis Eksperimen Dan Numerik. Masters thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 6014202007-Master_Thesis.pdf] Text
6014202007-Master_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 April 2025.

Download (4MB) | Request a copy

Abstract

Masalah polusi udara merupakan masalah yang harus menjadi perhatian utama manusia saat ini. Hal ini dikarenakan maraknya penyakit pernapasan menular yang sedang menjadi kekhawatiran masyarakat mayoritas. Pasalnya, penyakit ini telah menjangkit di dalam tubuh ratusan juta manusia, bahkan jutaan dari mereka terbunuh karenanya. Polusi udara ada yang berasal dari dalam ruangan (indoor) dan dari luar ruangan (outdoor). Polusi udara indoor sering kali tercipta dari beragam aktivitas manusia di dalamnya, seperti merokok, memasak, dan lain-lain. Selain dari aktivitas manusia, polusi udara indoor juga bisa disebabkan oleh hewan yang masuk ke dalam rumah, seperti kucing, anjing, tikus, dan lain-lain. Karena banyaknya sumber polutan yang dapat menjadikannya terakumulasi di dalam ruangan, maka ventilasi udara merupakan hal yang wajib tersedia di dalam ruangan tersebut. Ventilasi udara biasanya diwujudkan dengan cara membuka jendela. Dengan adanya ventilasi udara, maka polutan di dalam ruangan dapat berkurang karena udara di dalam ruangan bercampur dengan udara di luar ruangan. Namun pada beberapa kasus, kualitas udara outdoor menjadi lebih buruk dibandingkan dengan indoor dikarenakan banyaknya aktivitas manusia seperti lalu lalang kendaraan dan industri. Terlebih lagi, jika saat musim kemarau tiba, udara outdoor sangat panas sehingga menciptakan kondisi thermal comfort yang kurang untuk berkegiatan di dalam ruangan. Sehingga diperlukan solusi tambahan agar udara indoor tetap terjaga kesehatannya, yakni dengan menggunakan air purifier filter HEPA (High-Efficiency Particulate Absorbing). Telah banyak penelitian yang membuktikan efektivitas dari air purifier filter HEPA untuk menurunkan polutan di dalam ruangan. Akan tetapi hingga saat ini, belum ada penelitian mengenai konfigurasi air purifier dengan paduan ventilasi udara dan AC yang tepat agar secara bersamaan dapat menurunkan polutan dan memberikan kenyamanan suhu untuk beraktivitas di dalam ruangan secara optimal. Hal tersebut yang mendasari penelitian yang dilakukan ini. Hasil efisiensi removal polutan yang didapatkan dari variasi penggunaan air purifier dengan kombinasi jendela terbuka – AC on adalah sebesar 92%, kemudian hasil efisiensi removal polutan dari penggunaan air purifier, dan peletakkan arah aliran inlet dan outlet terbaik adalah di variasi inlet terhalang – outlet tidak terhalang, dengan efisiensi removal polutan sebesar 99%. Hasil yang ditunjukkan juga melalui analisis numerik, yakni dengan validasi teori menggunakan teknologi CFD, software Ansys fluent R1 2022 Student Version. Model yang digunakan adalah Eulerian-Lagrangian (Discrete Phase Modelling) k-epsilon, realizeable, dan Menter-Lechner near wall treatment
======================================================================================================================================
The problem of air pollution is a problem that must be the main concern of humans at this time. This is due to the rise of infectious respiratory diseases which are currently a concern for the majority of society. The reason is, this disease has infected the bodies of hundreds of millions of people, even millions of them have been killed because of it. There is air pollution that comes from indoors (indoor) and from outdoors (outdoor). Indoor air pollution is often created from various human activities in it, such as smoking, cooking, and others. Apart from human activities, indoor air pollution can also be caused by animals that enter the house, such as cats, dogs, rats, and others. Because there are many sources of pollutants that can accumulate in the room, ventilation is mandatory in the room. Air ventilation is usually realized by opening windows. With air ventilation, indoor pollutants can be reduced because indoor air mixes with outdoor air. However, in some cases, outdoor air quality is worse than indoor due to many human activities such as passing vehicles and industry. What is more, is when the dry season arrives, the outdoor air is very hot, thus creating less thermal comfort conditions for activities indoors. So an additional solution is needed to keep indoor air healthy, namely by using a HEPA (High-Efficiency Particulate Absorbing) air purifier. There have been many studies that prove the effectiveness of HEPA filter air purifiers to reduce indoor pollutants. However, until now, there has been no research on the configuration of an air purifier with the right combination of air ventilation and air conditioning so that it can simultaneously reduce pollutants and provide optimal temperature comfort for indoor activities. This is the basis for this research. Pollutant removal efficiency results obtained from variations in the use of air purifiers with the combination of open windows - AC on is 92%, then the results of pollutant removal efficiency from the use of air purifiers, and laying the best inlet and outlet flow directions are in unobstructed inlet - outlet variations, with pollutant removal efficiency of 99%. The results are also shown through numerical analysis, namely by theory validating using CFD technology, the Ansys fluent R1 2022 Student Version software. The model used is Eulerian-Lagrangian (Discrete Phase Modelling) k-epsilon, realizeable, and Menter-Lechner near wall treatment

Item Type: Thesis (Masters)
Uncontrolled Keywords: Air Purifier, CFD, Polutan Indoor, Ventilasi, Air Purifier, CFD, Indoor Pollutant, Ventilation.
Subjects: T Technology > TD Environmental technology. Sanitary engineering > TD883 Air quality management.
T Technology > TD Environmental technology. Sanitary engineering > TD883.5 Air--Pollution
Divisions: Faculty of Civil, Planning, and Geo Engineering (CIVPLAN) > Environmental Engineering > 25101-(S2) Master Thesis
Depositing User: Nadinda Aisyah Kamilia
Date Deposited: 03 Feb 2023 06:26
Last Modified: 03 Feb 2023 06:26
URI: http://repository.its.ac.id/id/eprint/96116