Monitoring Status Fuse Cut Out Pada Area Tegangan Menengah Di Gardu Trafo Distribusi Menggunakan Metode Logika Fuzzy

Nurjaman, Farhan Zawahir (2023) Monitoring Status Fuse Cut Out Pada Area Tegangan Menengah Di Gardu Trafo Distribusi Menggunakan Metode Logika Fuzzy. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 2040211122_UnderGraduate_Thesis.pdf] Text
2040211122_UnderGraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only until April 2025.

Download (5MB) | Request a copy

Abstract

PT. PLN (Persero) sebagai perusahaan yang bergerak di bidang ketenagalistrikan bertugas untuk melayani pasokan energi listrik. Pada sebuah jaringan listrik tegangan menengah, beberapa peralatan proteksi yang sering dipasang salah satunya adalah Fuse cut out (FCO). Peralatan ini merupakan proteksi pada gardu distribusi yang bekerja apabila terjadi gangguan arus lebih biasanya disertai dengan percikan api. Dibutuhkan alat untuk mendeteksi adanya gangguan yang terjadi pada FCO sehingga dapat mempercepat proses penormalan. Maka penelitian ini menggunakan mekanisme deteksi titik api pada FCO pada saat terjadi gangguan dan monitoring tegangan setelah FCO menggunakan logika fuzzy. Sistem ini terdiri dari mikrokontroler Arduino Mega 2560 sebagai unit kontrol, sensor UVTron sebagai pendeteksi titik api, sensor tegangan ZMPT101B sebagai monitoring tegangan pada jaringan listrik, buzzer sebagai suara alarm, Modem Robustel 4G R3000 L4I mengirimkan sinyal ke server, modbus RTU sebagai protokol komunikasi dan Software ASE2000 sebagai uji kontrol dan akuisisi data. Hasil dari pengujian yang telah dilakukan sensor UVTron mendeteksi titik api hingga jarak 550 cm, dengan sudut 45° sampai 135° secara horizontal maupun vertikal. Kemudian sensor tegangan ZMPT101B memiliki rata - rata error pembacaan sebesar 0,94 %. Kinerja sistem menggunakan logika fuzzy pada program di arduino menghasilkan akurasi ketepatan 100% dari hasil uji coba yang dibandingkan dengan rule inference Matlab. Sedangkan pemograman tanpa menggunakan logika fuzzy memperoleh kesalahan 2 kali dari 10 kali uji coba yang dilakukan. Proses pengiriman data melalui uji simulasi kontrol dan akuisisi data dapat dilakukan ditandai dengan pertukaran syntax frame pada master dan slave di ASE2000, seperti proses membaca input yang ditandai dengan nilai 0 pada saat keadaan normal dan 1 pada saat terjadi gangguan dan juga proses reset latcher menggunakan force single coil dapat dilakukan.

================================================================================================================================
PT. PLN (Persero) as a company engaged in the electricity sector is tasked with serving the supply of electrical energy. In a medium voltage power network, some protection equipment that is often installed, one of which is Fuse cut out (FCO). This equipment is a protection in the distribution substation that works when there is an overcurrent disturbance, usually accompanied by a spark. A tool is needed to detect disturbances that occur in the FCO so that it can speed up the normalization process. So this study uses a mechanism for detecting hotspots on the FCO when a disturbance occurs and monitoring the voltage after the FCO uses fuzzy logic. This system consists of an Arduino Mega 2560 microcontroller as a control unit, a UVTron sensor as a spark detector, a ZMPT101B voltage sensor as a voltage monitor on the power grid, a buzzer as an alarm sound, the Robustel 4G R3000 L4I Modem sends a signal to the server, the RTU modbus as a communication protocol and ASE2000 software as test control and data acquisition. The results of the tests that have been carried out by the UVTron sensor detects hotspots up to a distance of 550 cm, at an angle of 45° to 135° horizontally and vertically. Then the ZMPT101B voltage sensor has an average reading error of 0.94%. System performance using fuzzy logic in programs on Arduino produces 100% accuracy of the trial results compared to Matlab's rule inference. While programming without using fuzzy logic gets errors 2 times out of 10 trials conducted. The process of sending data through control simulation test and data acquisition can be done characterized by the exchange of syntax frames on the master and slave in ASE2000, such as the process of reading the input is characterized by a value of 0 in the normal state and 1 in the event of interference and also the process of resetting the latcher using a single coil force can be done.

Item Type: Thesis (Other)
Uncontrolled Keywords: Gangguan Jaringan Listrik, Fuse Cut Out, Sensor Api, Sensor Tegangan, RTU. Electrical Network Disturbance, Fuse Cut Out, Fire Sensor, Voltage Sensor, RTU.
Subjects: Q Science > QA Mathematics > QA9.64 Fuzzy logic
T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK3070 Automatic control
Divisions: Faculty of Vocational > 36304-Automation Electronic Engineering
Depositing User: Farhan Zawahir Nurjaman
Date Deposited: 13 Feb 2023 04:58
Last Modified: 13 Feb 2023 04:58
URI: http://repository.its.ac.id/id/eprint/96811