Studi Numerik Pola Penyebaran Aerosol Virus Covid-19 Pada Ruang Kelas Dengan Variasi Sistem Ventilasi

Simanjuntak, Jefry Anthony (2023) Studi Numerik Pola Penyebaran Aerosol Virus Covid-19 Pada Ruang Kelas Dengan Variasi Sistem Ventilasi. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 02111840000190-Undergraduate_Thesis.pdf] Text
02111840000190-Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 April 2025.

Download (13MB) | Request a copy

Abstract

Coronavirus Disease atau biasa disebut Virus Covid-19 adalah salah satu penyakit menular yang menyerang sistem pernapasan atau biasa disebut pneumonia yang disebabkan oleh virus SARS-Cov-2. Dengan adanya virus ini maka aktivitas manusia menjadi terbatas, termasuk aktivitas belajara mengajar yang biasa dilakukan di ruang kelas. Seiring berjalannya waktu dan seiring menurunnya angka orang yang terkonfirmasi positif Virus Covid-19 maka aktivitas manusia mulai kembali seperti semula tidak terkecuali aktivitas belajar mengajar yang mulai dikembali dilakukan di ruangan kelas. Upaya pencegahan terinfeksi virus di dalam ruang kelas harus terus dilakukan dengan vaksinasi, menjaga kesehatan, menjaga kebersihan tubuh. Dalam kondisi ruangan tertutup yang memiliki sistem ventilasi seperti jendela dan pintu, upaya pencegahan terinfeksi virus ini dapat dilakukan dengan mengatur sistem ventilasi yang terdapat dalam ruangan tersebut. Penelitian ini menggunakan model dengan geometri tiga dimensi suatu ruangan kelas berukuran 10 m ×7 m ×3 m yang berkapasitas 36 orang mahasiswa dengan seorang dosen yang berperan sebagai carrier Virus Covid-19. Penelitian ini menerapkan model turbulensi k-ε RNG. Boundary Condition yang digunakan adalah velocity inlet untuk kedua unit AC, untuk bagian outlet seperti jendela dan pintu menggunakan pressure outlet. Untuk kecepatan penyebaran partikel sebesar 10 m/s dengan temperatur partikel sebesar 37 oC. Dari penelitian ini diperoleh bahwa, skema dengan pintu terbuka dan kedua AC dikondisikan beroperasi pada kecepatan rendah adalah skema paling baik karena hanya menginfeksi 5 mahasiswa saja. Skema dengan seluruh sistem ventilasi tertutup dengan kedua AC dikondisikan beroperasi pada kecepatan tinggi adalah skema paling buruk karena menginfeksi 25 mahasiswa. Posisi duduk yang sejajar dengan sumber partikel yaitu posisi duduk 6, 12, 18, 24, 30 dan 36 adalah posisi duduk yang paling sering terinfeksi partikel aerosol Virus Covid-19 berdasarkan hasil simulasi setiap skema
=====================================================================================================================================
Coronavirus Disease or commonly called Virus Covid-19 is an infectious disease that attacks the respiratory system or commonly called pneumonia caused by the SARS-Cov-2 virus. With this virus, human activities are limited, including teaching and learning activities that are usually carried out in the classroom. As time went on and as the number of people who were confirmed positive for the Covid-19 Virus decreased, human activities began to return to normal, including teaching and learning activities which began to be resumed in classrooms. Efforts to prevent infection with the virus in the classroom must continue to be carried out by vaccinating, maintaining health, maintaining body hygiene. In closed room conditions that have ventilation systems such as windows and doors, efforts to prevent infection with this virus can be done by adjusting the ventilation system in the room. This study uses a model with a three-dimensional geometry in a classroom measuring 10 m × 7 m × 3 m with a capacity of 36 students with a lecturer acting as a carrier for the Covid-19 virus. This study applies the k-ε RNG turbulence model. The Boundary Condition used is the velocity inlet for both AC units, for the outlet parts such as windows and doors using a pressure outlet. For particle spreading velocity of 10 m/s with particle temperature of 37 oC. From this study, it was found that the scheme with the door open and both air conditioners conditioned to operate at low speed was the best scheme because it only infected 5 students. The scheme with all closed ventilation systems with both air conditioners conditioned to operate at high speed is the worst scheme because it infects 25 students. Sitting positions that are parallel to the source of the particles, namely sitting positions 6, 12, 18, 24, 30 and 36 are the sitting positions that are most often infected with the Covid-19 Virus aerosol particles based on the simulation results of each scheme

Item Type: Thesis (Other)
Uncontrolled Keywords: covid-19, ventilation, concentration, mobilization, covid-19, ventilasi, konsentrasi, penyebaran
Subjects: T Technology > TJ Mechanical engineering and machinery