Hidayat, Muhammad Rifat (2023) Studi Numerik Penggunaan Multi Layer Direction Angle Wiremesh Sebagai Sistem Perkuatan Confined Masonry Terhadap Beban Siklik Horizontal. Masters thesis, Institut Teknologi Sepuluh Nopember.
Text
6012211036-Master_Thesis.pdf - Accepted Version Restricted to Repository staff only until 1 October 2025. Download (7MB) | Request a copy |
Abstract
Indonesia merupakan daerah yang rawan gempa dan terletak diantara tiga lempengan tektonik dunia. Ketahanan konstruksi yang memenuhi standar diperlukan didaerah rawan gempa. Hal ini bertujuan untuk melindungi penghuni bangunan pada waktu gempa terjadi dan mengurangi resiko dari kerusakan akibat beban gempa yang besar. Akan tetapi lebih dari 70 % bangunan yang ada di negara berkembang seperti Indonesia memiliki sistem struktur Confined Masonry (CM). Penggunaan sistem CM di Indonesia seringkali menghasilkan kerusakan yang fatal jika terjadi gaya gempa. Akibat jenis kerusakan yang fatal ketika terjadi gaya gempa, penambahan sistem perkuatan pada sistem CM menjadi salah satu opsi untuk memperbaiki kekurangan dari sistem CM. Terdapat banyak jenis material yang dapat digunakan sebagai material perkuatan seperti penggunaan steel cage, polymer, polyprophylene band, bamboo meshes, dan material plastik. Penelitian ini meneliti penggunaan dari penggunaan lapisan ferrocement sebagai material perkuatan dari panel sistem struktur CM, panel spesimen yang digunakan memiliki lebar 2300 mm dan tinggi dari panel 1370 mm. Spesimen pada penelitian dimodelkan secara numerik. Variasi penelitian berfokus pada pengaruh penggunaan jumlah layer serta sudut orientasi dari lembaran wiremesh. Jumlah variasi layer dari ferrocement yang digunakan adalah satu hingga dua layer dengan variasi konfigurasi sudut 0o, 45o dan 60o dan lapisan perkuatan ini diaplikasikan pada salah satu sisi panel CM pada spesimen single sided. Dan untuk variasi spesimen dual sided lapisan perkuatan diaplikasikan pada kedua sisi panel Sebagai perbandingan hasil spesimen kontrol disertakan. Hasil kurva histeretik, Disipasi energi, penurunan kekakuan dan pola kerusakan yang terjadi dievaluasi pada penelitian ini. Dan didapatkan hasil bahwa penggunaan single sided pada sistem CM memberikan kerusakan yang prematur akibat adanya kerusakan torsi dan untuk double sided memberikan hasil yang lebih optimal.
==================================================================================================================================
Indonesia is an earthquake-prone area and is located between three of the world's tectonic plates. Construction resistance that meets the requirements is needed in earthquake-prone areas. This aims to protect and reduce the risk of damage due to large earthquake loads. However, more than 70% of buildings in developing countries such as Indonesia have a Confined Masonry (CM) structural system. The use of the CM system in Indonesia often results in fatal damage if an earthquake occurs. As a result of the type of damage that is fatal when an earthquake occurs, the addition of a reinforcement system to the CM system is an option to correct the deficiencies of the CM system. There are many types of materials that can be used as reinforcement materials such as the use of steel cages, polymers, polypropylene bands, bamboo meshes, and plastic materials. This study will examine the use of the use of ferrocement layers as a reinforcement material for CM structural system panels, the specimen panels used have a width of 2300 mm and a height of 1370 mm panels. Specimens in the study were modeled numerically using the ABAQUS/explicit program. Variations of research focus on the effect of using the number of layers and the orientation angle of the wiremesh sheet. The number of layer variations of the ferrocement used is one to two layers with variations in angle configurations of 0o, 45o and 60o and this reinforcement layer is applied to one side of the CM panel on single sided specimens. And for the dual sided specimen variation the reinforcement layer is applied on both sides of the panel. For comparison the results of the control specimens are included. The results of hysteretic curves, energy dissipation, stiffness reduction and damage patterns that occur evaluated in this study. And the results show that the use of single sided on the CM system gives premature damage due to torsion damage and for double sided gives more optimal results.
Item Type: | Thesis (Masters) |
---|---|
Uncontrolled Keywords: | Confined Masonry, Masonry Wall, Wiremesh, Ferrocement |
Subjects: | T Technology > TA Engineering (General). Civil engineering (General) > TA645 Structural analysis (Engineering) |
Divisions: | Faculty of Civil, Planning, and Geo Engineering (CIVPLAN) > Civil Engineering > 22101-(S2) Master Thesis |