ANALISIS TERMAL SISTEM UDARA KOMPRESI BERTINGKAT (35-K-1A DAN 35-E) PADA PT BADAK LNG

ROSALINA, NIA (2016) ANALISIS TERMAL SISTEM UDARA KOMPRESI BERTINGKAT (35-K-1A DAN 35-E) PADA PT BADAK LNG. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[img]
Preview
Text
2112100034_undergrdauate thesis.pdf - Published Version

Download (4MB) | Preview

Abstract

Di dalam dunia industri, banyak sekali komponen penunjang proses produksi atau operasi dari sebuah pabrik diantaranya adalah pompa, kompresor, heat exchanger, turbin, dan boiler. PT Badak LNG menggunakan kompresor bertingkat untuk menunjang operasi pabrik. Di dalam sistem kompresor bertingkat terdapat sebuah komponen yang berfungsi untuk membantu kerja dari kompresor yakni komponen intercooler. Komponen ini berfungsi untuk menurunkan temperatur udara bertekanan keluaran satu tingkat kompresor yang akan masuk kedalam kompresor tingkat berikutnya. Operasi sistem kompresi bertingkat sering mengalami penurunan performansi. Penurunan performa ini sangat sering terjadi, terutama pada jenis kompresor tersebut. Penurunan performa diakibatkan oleh dua hal, yakni adanya penurunan tekanan pada intercooler dan terjadinya kebocoran di beberapa sambungan pipa. Oleh sebab itu diperlukan sebuah analisis termal untuk mengetahui pengaruh adanya penurunan tekanan yang terjadi di intercooler terhadap penurunan performa kompresor. Metode analisis didasarkan pada analisis termodinamika dan perpindahan panas. Analisis termodinamika digunakan untuk meninjau kesetimbangan massa dan konservasi energi pada intercooler, sedangkan analisis perpindahan panas digunakan untuk meninjau unjuk kerja atau performa dari intercooler. Data yang didapat untuk analisis merupakan data hasil kerja praktek lapangan di PT Badak LNG Berdasarkan dengan hasil penelitian dan perhitungan didapatkan bahwa nilai efisiensi per stage pada kompresor mengalami penurunan dibandingkan saat comissioning. Kemudian nilai effectiveness intercooler 2 terletak dibawah nilai effectiveness intercooler 1. Selain itu nilai pressure drop intercooler 2 lebih tinggi dibandingkan dengan intercooler 1 sehingga diindikasikan bahwa performa intercooler mengalami penurunan. Berdasarkan hasil penelitian didapatkan bahwa secara sistem kompresor masih berjalan dengan baik, namun sudah tidak sesuai dengan spesifikasi sehingga diindikasikan bahwa kompresor mengalami low performance. "=============================================================================================" In the industrial, there are many equipment used for supporting the production process or the operation of a plant, for example pump, compressor, heat exchanger, turbine and boiler. PT Badak LNG use multistage compressor for supporting the operation process of the plant. In the multistage air compression system, there is equipment used for supporting the work of a compressor, that is intercooler. Intercooler is used for reducing the temperature of compressed air from the discharge of a stage before the compressed air enter the other stages. The multistage air compression system often has low performance especially for the compressor. The reduction of the performance is caused by two factors, there are reduction of the pressure in the intercooler and the presence of leakage in the pipe connection. Because of that, it requires a thermal analysis to know the effect of pressure drop in the intercooler to the performance of the compressor. The analysis method is based on thermodynamic analysis and heat transfer. The thermodynamic analysis is used for analyzing mass balance and energy balance in the intercooler, while the heat transfer analysis is used for analyzing the performance of the compressor. Data used for analyzing is the result of internship at PT Badak LNG. Based on the research and the calculation of the efficiency in the stage of compressor has decreased compared to commissioning. Then the effectiveness intercooler 2 value less than effectiveness intercooler 1. In addition the value of pressure drop intercoolers 2 higher than the intercooler 1, that is to indicated the low performance of intercooler . Based on the the research showed that the system of compressor is still running well, but the indicated of compressor is low performance.

Item Type: Thesis (Undergraduate)
Additional Information: RSM 621.402 5 Ros a
Uncontrolled Keywords: Intercooler, Kompresor, Efisiensi
Subjects: T Technology > TJ Mechanical engineering and machinery
Divisions: Faculty of Industrial Technology > Mechanical Engineering > 21201-(S1) Undergraduate Thesis
Depositing User: Users 13 not found.
Date Deposited: 11 Jan 2017 06:49
Last Modified: 27 Dec 2018 06:34
URI: https://repository.its.ac.id/id/eprint/1478

Actions (login required)

View Item View Item