Analisis Kualitas Air Pada Sistem Dearator Di Pt.X

Winarno, Rendy (2017) Analisis Kualitas Air Pada Sistem Dearator Di Pt.X. Diploma thesis, Institut Teknologi Sepuluh November.

[thumbnail of 1314030091-Non_Degree.pdf]
Preview
Text
1314030091-Non_Degree.pdf - Published Version

Download (1MB) | Preview

Abstract

Energi listrik merupakan suatu kebutuhan pokok bagi kehidupan manusia saat ini dan masa yang akan datang, dimana energi listrik digunakan untuk melakukan berbagai aktifitas dalam kehidupan sehari-hari. Salah satu penyumbang energi di Indonesia adalah PT. X. Pada penelitian ini bertujuan untuk mengetahui bagaimana kapabilitas proses dari kualitas air pada sistem dearator di PT. X pada bulan Februari dan Maret 2017 dengan variabel yang digunakan adalah conductivity dan tingkat keasaman. Secara umum didapatkan bahwa kualitas air bulan Februari dan pada bulan Maret indeks kapabilitas proses yang Mp> 1 dan Mpk< 1yang artinya proses belum kapabel, didapatkan bahwa kualitas dari air terjadi penurunan akan tetapi kualitas air semakin mendekati batas yang telah ditentukan oleh perusahaan yang, akan tetapi jika dilihat dari tiap variabel didapatkan varibel conductivity memiliki nilai presisi dan akurasi > 1 yang artinya proses telah kapabel sedangkan varibel tingkat keasaman memiliki nilai presisi dan akurasi < 1 yang artinya proses belum kapabel. Faktor –faktor penyebab utama tidak terkendalinya proses secara keseluruhan adalah conductivity yang melebihi batas spesifikasi perusahaan yang disebabkan oleh faktor pengukuran, material, sistem dan mesin.
============================================================================= Electrical energy is a basic requirement for human life today and the future, where electrical energy is used to perform various activities in everyday life. One of the energy contributors in Indonesia is PT. X. In this study aims to determine how the process capability of water quality in the dearator system at PT. X in February and March 2017 with the variables used are conductivity and acidity level. It is generally found that the quality of water in February and in March the index capability prosess Mp> 1 and Mpk <1 which means the process is not yet capable, it is found that the quality of the water decreases but the water quality is closer to the limit determined by the company which will But when viewed from each variable obtained variables conductivity ymemiliki precision and accuracy value> 1 which means the process has kapabel while the acidity level variables have precision and accuracy value <1 which means the process is not yet capable. The main factors causing uncontrolled processes over all are conductivity that exceeds the company's specification limits caused by measurement factors, materials, systems and machinery.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Dearator, Kapabilitas proses, Kuaitas Air, Peta Kendali.
Subjects: Q Science > Q Science (General)
Divisions: Faculty of Vocational > 49501-Business Statistics
Depositing User: Rendy Winarno
Date Deposited: 27 Sep 2017 06:00
Last Modified: 06 Mar 2019 03:19
URI: http://repository.its.ac.id/id/eprint/43872

Actions (login required)

View Item View Item