Di Indonesia listrik diproduksi dengan bahan bakar fosil. Hal
tersebut mengakibatkan Indonesia masih berkontribusi besar
dalam menyumbang emisi karbondioksida di dunia. Melihat hal
tersebut maka pada tugas akhir ini dirancang suatu mini plant
Stirling Engine atau mesin stirling. Mesin ini memanfaatkan
sistem control ON – OFF, dengan sensor yang digunakan adalah
termokopel tipe K. Pada sistem ini, apabila data yang dikirimkan
oleh sensor lebih dari set point (275°C) maka mikrokontroler
memerintahkan motor untuk mengurangi nyala dari api burner.
Namun, jika data kurang dari set point (275°C) maka
mikrokontroler memerintahkan motor untuk membuka valve.
Nilai suhu yang dihasilkan ditampilkan pada LCD. Berdasarkan
pengujian ini didapat hasil minimum 0.13mV dengan suhu30°C.
Hasil maksimum 2.97 mV dengan suhu 100°C . Sedangkan hasil
pengujian dengan input process variable (PV) dapat diketahui
sinyal error sebesar 0.27. Semakin tinggi nilai error maka MV
akan semakin besar juga (linier).
===========================================================================================================
In indonesia, electricity produced by fossil fuels.It was
resulting in indonesia still had a great contribution to emissions
of carbon dioxide in the world. See it and in the end it was
designed some mini plant stirling engine or stirling engine. The
machine was a control system on - off, the sensors that are used
in a thermocouple type K. In this system, when the data sent by
the censors more than a set point (275°C microcontroller
motorcycle and ordered to reduce the flame of fire burner.
However, if this data is less than a set point (275°C and
microcontroller motor command to add flame from burner. The
temperature produced displayed in the lcd window.Based on the
results of the test were minimum 0.4mV with themperature 30°C.
The maximum 2.4 mV temperatures 100°C. While the testing with
input variable ( pv process ) can be detected the error by 0.27.
The higher the value of the error , the MV will be the greater the (
linear ) . The higher the value of the error , the MV will be more

Item Type: Thesis (Diploma)
Additional Information: RSF 629.895 Suh r
Uncontrolled Keywords: Stirling Engine, Thermocouple Type K, Burner
Subjects: Q Science > QA Mathematics > QA76 Computer software > QA76.8 Microprocessor
Divisions: Faculty of Industrial Technology > Physics Engineering > (D3) Diploma 3
Depositing User: Mr. Tondo Indra Nyata
Date Deposited: 27 Mar 2018 05:00
Last Modified: 24 Aug 2018 06:56
URI: http://repository.its.ac.id/id/eprint/51642

Actions (login required)

View Item View Item