Suatu ruang dikatakan baik jika memiliki nilai Transmission Loss (TL) yang besar. Penelitian ini bertujuan untuk meningkatkan daya isolasi ruang sumber dengan menggunakan metode pelapisan gypsum board 12 mm pada semua sisi dan menambahkan ketebalan pada sekat sehingga dapat menguji bahan tebal. Variasi bahan yang diuji berupa gypsum satu lapis, gypsum dua lapis, serta partisi berlapis, dan diperoleh peningkatan STC sebelum dan sesudah perbaikan berturut-turut yaitu 2 dB, 2 dB, dan 8 dB. Peningkatan STC dikarenakan berkurangnya transmisi sisi. Pada dinding partisi yang telah dilapisi gypsum masih terdapat transmisi sisi. Besarnya transmisi sisi dapat ditunjukkan dengan nilai NR masing-masing partisi. Pada frekuensi 1000 Hz nilai NR terbesar terdapat pada titik 2 yaitu 36,19 dB, sedangkan nilai NR terendah adalah titik 1 yaitu 32,90dB. Sehingga ruang sumber hanya mampu mengukur bahan dibawah 32,90 dB pada frekuensi 1000 Hz =================================================================================================== The room has good quality if the transmission loss value is large. This search purpose to increase the isolation of space resources by gypsum board 12 mm by coating method on all sides and add thickness to the bulkhead so as to test the thick material. Variation of materials tested in the form of gypsum one layer, two layers of gypsum and layered partition, and obtained an increase in STC before and after repair in a row that is 2 dB, 2 dB, and 8 dB. STC enhancement due to the reduced flanking transmission. The partition walls are still flanking transmittion after coating gypsum. The magnitude of the transmission side can be shown by the value of Noise Reduction (NR) of each partition. At a frequency of 1000 Hz,The largest NR value at point 2 is 36.19 dB, while the lowest value of NR at point 3 is 32,90 dB. So the source room can be measuring the material under 32.90 dB at a frequency of 1000 Hz.

Item Type: Thesis (Undergraduate)
Additional Information: RSFi 620.2 Nug p
Uncontrolled Keywords: Gypsum, Rugi transmisi, Sound Transmission Class, Transmisi sisi, partisi
Subjects: Q Science > QC Physics > QC221 Acoustics. Sound
Divisions: Faculty of Mathematics and Science > Physics > 45201-(S1) Undergraduate Thesis
Depositing User: Mr. Tondo Indra Nyata
Date Deposited: 05 Nov 2019 01:38
Last Modified: 05 Nov 2019 01:38
URI: https://repository.its.ac.id/id/eprint/71592

Actions (login required)

View Item View Item