Rancang bangun pengendalian flow menggunakan motorrized operated valve (Mov; Berbasis padda proses control laut

Faisal, Muhammad Reza (2016) Rancang bangun pengendalian flow menggunakan motorrized operated valve (Mov; Berbasis padda proses control laut. Diploma thesis, Institut Teknologi Sepuluh Nopember.

[img]
Preview
Text
2413031006-non degree thesis.pdf

Download (1MB) | Preview

Abstract

Sistem pengendalian flow pada process control system plant merupakan sistem yang digunakan untuk mengendalikan flow. Pada perancangan sistem pengendalian flow ini, sensor yang digunakan untuk mengukur flow adalah sensor flowmeter 1” yang dilengkapi dengan rangkaian pengkondisian sinyal frequency to voltage (FTV) dan rangkaian komparator. Rangkaian FTV digunakan untuk merubah frekuensi ke tegangan, sedangkan komparator digunakan untuk merubah sinyal analog output dari FTV menjadi sinyal digital. Output dari sensor flowmeter akan mengukur flow yang ada dan akan memberikan respon ke PLC saat setpoint flow tercapai sehingga MOV sebagai aktuator flow akan merespon. Dari data respon pengendalian yang didapat menunjukkan bahwa pengendalian telah berjalan sesuai dengan setpoint yang diinginkan yaitu 18 liter/menit dan berjalan dengan stabil. selain itu berdasarkan pengujian alat pada sistem pengendalian flow didapatkan respon time yang cukup baik untuk mencapai stedy state dengan maksimum overshoot 19 liter/menit. Waktu yang dibutuhkan untuk mencapai set point (settling time) dari awal pengambilan data adalah ± 55 detik. ====================================================================================================== Flow control system in process control system plant is a system that used to control flow. On designing control system flow this, the sensor used to measure flow is sensors flowmeter 1” equipped with a circuit of conditioning signals frequency to voltage ( FTV ) and komparator circuit. A series of ftv used to change frequency to voltage, while komparator used to change analogue signals the output of ftv into digital signals.The output of flowmeter sensor will measure flow will respond to plc when setpoint flow achieved so MOV as actuator flow will respond. From the data response control obtained shows that control has been running in accordance with setpoint desired that is 18 liters per minutes and walked with a steady. in addition based on testing instrument in control system flow obtained response time is a good enough to reach steady state with only a maximum overshoot 19 liters per minute .The time it takes to reach set point ( settling time ) from the beginning of the data sampling is ± 55 seconds .

Item Type: Thesis (Diploma)
Additional Information: RSF 621.313 Fai r-1
Uncontrolled Keywords: Sistem Pengendalian flow, Flowmeter, MOV, PLC
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ910 Electric pumping machinery
Divisions: Faculty of Industrial Technology > Physics Engineering > (D3) Diploma 3