Kondensor merupakan salah satu jenis heat exchanger yang berfungsi mengkondensasikan fluida gas menjadi cair. Dibutuhkan material tube yang kuat dan dapat melakukan perpindahan panas yang baik agar tidak terjadi penurunan laju perpindahan panas di dalam kondensor. Jika laju perpindahan panas rendah, mengakibatkan kerja netto akan semakin meningkat. Mengetahui peran kondensor sangat penting dalam suatu siklus, maka perlu dilakukan analisa laju perpindahan panas kondensor Unit 3 PT. PLTU UP Gresik. Kondensor Unit 3 adalah kondensor yang telah di redtubing dengan material tube titanium. Titanium memiliki kekuatan material yang lebih kuat dibandingkan aluminium brass material sebelumnya, sehingga kebocoran pada tube dapat dikurangi dengan menggunakan material titanium. Data yang diambil dari tugas akhir ini adalah data ratarata aktual selama 1 bulan, yaitu bulan Juni. Metode perhitungan untuk menghitung laju perpindahan panas dan efektivitas adalah Log Mean Temperature Different (LMTD) dan Effectiveness – Number of Transfer Unit (NTU). Dari hasil perhitungan, dengan data kevakuman yaitu 0,079288 bar pada bulan Juni diketahui bahwa laju perpindahan panas sebesar 194,1226889 MW dengan efektivitas sebesar 0,9978764. Laju perpindahan panas pada kondensor dipengaruhi oleh kondisi kevakuman kondensor. Semakin tinggi kevakuman kondensor maka steam semakin mudah menuju kondensor, sehingga meningkatkan performa dari kondensor. =============================================================================================== Condensor is component that has an important rate in the efficiency of the cycle, it uses for for condensate from gas to liquid. Needed tube material strong and can heat transfer good for not effect heat transfer decreases on condenser. If the heat transfer small, netto worl’ will increase. To know how condenser work if need to calculate the heat tranfer of condensor at PT. PJB UP. Gresik PLTU Unit 3. Condensor unit 3 has been redtubing with materials titanium tube. Titanium have strength than aluminium brass, so lekeage on the tube can decreaes wich material titanium. In this final project, data taken the average of actual condition condenser for June. Whereas, the method used in this calculation of the heat transfer-rate and effectiveness is Log Mean Temperature Difference (LMTD) and Number of Transfer Unit (NTU) Method. From the calculation, it known that the vacuum data on June 2014 is 0,079288 bar and it known that the heat transfer is 194,1226889 MW witch effectiveness is 0,9978764. Heat transfer on condensor be affected to vacuum condition. The higher vacuum steam condensers then the easier it towards the condenser, thereby increasing the performance of the condenser .

Item Type: Thesis (Diploma)
Additional Information: RSM 621.402 2 Suc a
Uncontrolled Keywords: Kondensor, Laju Perpindahan Panas, Efektivistas
Subjects: Q Science > QC Physics > QC320 Heat transfer
Divisions: Faculty of Industrial Technology > Mechanical Engineering > 21401-(D3) Diploma 3
Depositing User: Mr. Marsudiyana -
Date Deposited: 13 Dec 2019 08:40
Last Modified: 13 Dec 2019 08:40
URI: https://repository.its.ac.id/id/eprint/72369

Actions (login required)

View Item View Item