Studi Eksperimen Perbandingan Unjuk Kerja Pompa Shimizu Ps-116 Bit Standar Dan Modifikasi Dengan Metode Pengujian Instalasi

Sakhty, Fhabry Refha (2016) Studi Eksperimen Perbandingan Unjuk Kerja Pompa Shimizu Ps-116 Bit Standar Dan Modifikasi Dengan Metode Pengujian Instalasi. Diploma thesis, Institut Teknologi Sepuluh Nopember Surabaya.

[img]
Preview
Text
2113030009-Non_Degree.pdf - Published Version

Download (2MB) | Preview

Abstract

Di kalangan masyarakat Rejotangen kabupaten Tulungagung belakangan ini, sering dijumpai modifikasi pada pompa standar dengan jalan mengubah impeler yang semula berjenis Radial menjadi Backward, disertai pula dengan perubahan pada volute chambernya. Modifikasi ini bertujuan untuk meningkatkan unjuk kerja pompa standar. Namun demikian nilai unjuk kerja sebenarnya dari pompa modifikasi ini belum diketahui. Pada tugas akhir ini dilakukan perhitungan berdasarkan pengujian instalasi dengan data dari hasil pengukuran. Perhitungan dilakukan pada pompa SHIMIZU PS-116 BIT standar dan modifikasi tanpa perubahan daya motor penggeraknya, dari hasil perhitungan yang didapat digunakan untuk membandingkan nilai unjuk kerjanya secara aktual. Pada perhitungan yang telah dilakukan didapat bahwa pada kondisi fully open nilai unjuk kerja pompa modifikasi lebih unggul dari pada pompa standar. Terbukti dengan nilai Head efektif pompa modifikasi memcapai 6.01262 m sedangkan pompa standar 5.00346 m, diikuti dengan nilai unjuk kerja yang lainya kapasitas pompa modifikasi memncapai 0.000889 m3/s sedangkan pompa standar 0.000389 m3/s, nilai WHP dan Nshaft pompa modifikasi mencapai 52.20463 watt dan 267.52 watt secara berurutan sedangkan untuk pompa standar 19.00614 watt dan 258.72 watt. Nilai terakhir adalah efisiensi, untuk pompa modifikasi mencapai 19.51429 % jauh dahi pompa standar yang hanya mencapai 7.346221 % ============================================================================================ In recent times, apply modification to the default pump becomes common among the people of Rejotangen, Tulungagung regency. They change pump impeller that was oroginally Radial type to be Backward type accompanied with the changes on its volute chamber. This modification aims to improve pump performance value. But however, the value of the actual performance of this pump modification is not yet known. In this final project was performed calculations based on testing the installation with data from measurement results. The calculation will be done on the pump SHIMIZU PS-116BIT standard and modification without change of its motor power. From the calculation result is used to compare the value of the actual work performance. On the calculation that had been done was obtained on the fully open condition of the modification pump performance rating is higher than the standard pump. With proven value the effective Head of modification pump reaches 6.01262 m whereas the standard pump 5.00346 m, followed by the value of the other performance modifications to the pump's capacity reached 0.000889 m3/s whereas the standard pump 0.000389 m3/s, a value Nshaft and WHP pump modification reaches 52.20463 watt and 267.52 Watts respectively whereas for standard pump 19.00614 Watts and 258.72 Watts. The last value is the efficiency, to pump modification reaches 19.51429% away from the standard pump only reached 7.346221%

Item Type: Thesis (Diploma)
Additional Information: RSM 621.67 Sak s
Uncontrolled Keywords: Head, Kapasitas, WHP, Nshaft, Efisiensi
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ919 Centrifugal pumps--Design and construction.
Divisions: Faculty of Industrial Technology > Mechanical Engineering > 21401-(D3) Diploma 3
Depositing User: EKO BUDI RAHARJO
Date Deposited: 22 Jul 2020 00:54
Last Modified: 22 Jul 2020 00:55
URI: https://repository.its.ac.id/id/eprint/76445