Rancang Bangun Sistem Instrumentasi Monitoring Pernapasan Manusia Dengan Sensor Plastic Optic Fibre (Pof) Berbasis User Interface Android

Wibowo, M Eko Yulianto (2016) Rancang Bangun Sistem Instrumentasi Monitoring Pernapasan Manusia Dengan Sensor Plastic Optic Fibre (Pof) Berbasis User Interface Android. Diploma thesis, Institut Teknologi Sepuluh Nopember Surabaya.

[thumbnail of 2413031059-Non_Degree.pdf]
Preview
Text
2413031059-Non_Degree.pdf - Published Version

Download (1MB) | Preview

Abstract

Serat optik (optic fibre) masih mempunyai peran penting sebagai media transimisi data dengan menggunakan cahaya sebagai sumber transmisinya. Kegunaan serat optik sebagai sensor dapat diimplementasikan di berbagai bidang, salah satunya adalah dalam bidang medis. Pada penelitian ini dilakukan untuk mengetahui pola pernapasan manusia dengan menggunakan serat optik plastik. Serat optik digunakan sebagai sensor dengan menghilangkan bagian cladding dalam serat optik untuk meningkatkan sensitivitas sensor untuk memantau sinyal pernapasan. Dari penelitian dilakukan monitoring pernapasan biasa, pernapasan disertai batuk dan kelelahan. Pernapsan biasa menghasilkan tegangan keluaran saat inspirasi adalah 2.584 Volt dan 2.219 saat ekspirasi, sedangkan untuk pernapasan disertai batuk tegangan keluaran saat inspirasi sekitar 2.5 Volt dan 2.109 Volt saat ekspirasi, dan pernapasan dengan kondisi kelelahan mempunyai tegangan keluaran sekitar 2.5 Volt saat inspirasi dan 2.1 Volt saat ekspirasi. Hasil keluaran berupa tegangan dapat ditampilkan secara real time melalui android dengan Operating system Jelly Bean 4.4.2
============================================================================================
Optical fiber still has a significant role as a medium for data transmission by using light as a source transmittion. The usefulness of optical fiber as the sensor can be implemented in various fields, one of which is in the medical field. In this study was conducted to determine the pattern of human respiratory using plastic optical fiber. Optical fiber is used as the sensor by removing part of the cladding of optical fiber to increase the sensitivity of the sensor to monitor respiratory signal. From research conducted regular monitoring of breathing, breathing with a cough and fatigue. Pernapsan ordinary produce output voltage when the inspiration is the 2.584 Volt and the 2.219 expiration, while for respiratory cough output voltage when the inspiration approximately 2.5 Volt and 2.109 Volt during expiration, and breathing in a state of exhaustion has the output voltage of about 2.5 volts during inspiration and 2.1 Volt time expiration. The output voltage can be displayed in real time via the operating system Android 4.4.2 Jelly Bean

Item Type: Thesis (Diploma)
Uncontrolled Keywords: RSF 681.25 Wib r
Subjects: Q Science > QC Physics > QC100.5 Measuring instruments (General)
T Technology > TA Engineering (General). Civil engineering (General) > TA1800 Fiber Optics
Divisions: Faculty of Industrial Technology > Physics Engineering > (D3) Diploma 3
Depositing User: EKO BUDI RAHARJO
Date Deposited: 30 Jul 2020 04:32
Last Modified: 30 Jul 2020 04:32
URI: http://repository.its.ac.id/id/eprint/76727