Rancang Bangun Sistem Monitoring Suhu Biogas Pada Input Purifikasi Dan Output Storage

Suradi, Rizki Amalia (2016) Rancang Bangun Sistem Monitoring Suhu Biogas Pada Input Purifikasi Dan Output Storage. Diploma thesis, Institut Teknologi Sepuluh Nopember Surabaya.

[img]
Preview
Text
2413031075-Non_Degree.pdf - Published Version

Download (2MB) | Preview

Abstract

Biogas merupakan salah satu sumber energi alternatif yang dapat dikonversi menjadi energi listrik . Biogas juga perlu di ukur suhunya agar tidak terjadi over heat pada sistem. Oleh karena itu diperlukan suatu alat yang dapat memonitoring suhu biogas pada input dan output purifikasi. Sensor Thermocouple mendeteksi suhu, setelah itu hasil keluaran dari sensor-sensor tersebut masuk ke dalam ADC (Analog To Digital Converter) untuk mengubah pembacaan analog menjadi sinyal digital dengan menggunakan MAX6675 agar bisa diproses. Sinyal masuk ke pemrosesan sinyal pada Arduino Uno dan dimonitor dengan sistem komunikasi Visual Studio 2013. Pada sistem monitoring ini didapatkan error pembacaan suhu adalah sebesar 0,131 yaitu sebesar (0,254%) sedangkan nilai Uexpand = 1.1856075 yaitu sebesar 0.00039%. Karakteristik statik dari alat ukur suhu ini antara lain resolusi=0.25, sensitivitas = 1,0345V/ºC, a = 0,735dan akurasi = 0.991 (99.009%). Jadi dapat disimpulkan bahwa alat ukur suhu ini layak digunakan karena memiliki Uexpand<5% dari pembacaan standard. Hasil pengujian suhu terrendah pada system purifikasi biogas yaitu 32ºC pada input dan 29.25 pada output, suhu tertinggi sebesar 34ºC pada input dan 30.75 pada output ============================================================================================= Biogas is one of the alternative energy sources that can be converted into electrical energy. Biogas is also necessary in measuring the temperature to avoid the over-heat on system. Therefore we need a tool which can monitor temperatures on the input and output biogas of purification. Thermocouple sensors detect temperature, then the output of the sensors entered into the ADC (Analog To Digital Converter) to convert analog readings into a digital signal using the MAX6675 to be processed. The incoming signal to the signal processing on the Arduino Uno and monitored with Visual Studio 2013 communication system. In this monitoring system temperature readings obtained error is equal to 0.131 or (0.254%), while the value Uexpand = 1.1856075 or 0.00039%. Static characteristics of temperature measuring devices, among others resolution = 0:25, sensitivity = 1,0345V / ºC, a = 0,735 and accuracy = 0.991 (99 009%). Therefore we can conclude that the temperature measuring devices is feasible to use because it has Uexpand <5% of the reading standard. The test results in the lowest temperature is 32ºC on biogas purification system at 29.25 at the input and output, the highest temperature of 34ºC at 30.75 at the input and output

Item Type: Thesis (Diploma)
Additional Information: RSF 629.895 Sur r
Uncontrolled Keywords: suhu, sensitivitas, karakteristik statik
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ223.P76 Programmable controllers
Divisions: Faculty of Industrial Technology > Physics Engineering > (D3) Diploma 3
Depositing User: EKO BUDI RAHARJO
Date Deposited: 07 Aug 2020 00:37
Last Modified: 08 Aug 2020 12:13
URI: https://repository.its.ac.id/id/eprint/77164

Actions (login required)

View Item View Item