Evaluasi Surface Dose Pada Kasus Breast Cancer Postmastectomy Dengan Teknik 3d Crt Menggunakan Energi Foton 6 Mv Dengan Bolus Dan Tanpa Bolus

Jannah, Nurul Habibatul (2021) Evaluasi Surface Dose Pada Kasus Breast Cancer Postmastectomy Dengan Teknik 3d Crt Menggunakan Energi Foton 6 Mv Dengan Bolus Dan Tanpa Bolus. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 01111740000077-Undergraduate_Thesis.pdf] Text
01111740000077-Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 October 2023.

Download (1MB) | Request a copy
[thumbnail of 01111740000077-Undergraduate_Thesis.pdf] Text
01111740000077-Undergraduate_Thesis.pdf
Restricted to Repository staff only

Download (1MB) | Request a copy

Abstract

Surface dose merupakan salah satu parameter penting dalam perawatan radioterapi, khususnya radiasi eksterna. Dalam penggunaan berkas foton, diperlukan material tambahan agar dapat meningkatkan dosis permukaan, misalnya bolus. Pada penelitian ini material yang digunakan sebagai bolus adalah silicone rubber dan silika gel dengan variasi ketebalan 0.5, 1 dan 1.5 cm. Tujuan penelitian ini adalah untuk mengetahui distribusi dosis permukaan pada bolus dan mengetahui nilai surface dose pada kasus kanker payudara pasca mastektomi menggunakan energy foton 6 MV. Uji distribusi dosis pada bolus dengan slab water phantom membuat dosis permukaan meningkat seiring dengan penggunaan bolus baik bolus SR maupun bolus SR dengan campuran silika gel, peningkatan dosis permukaan pada bolus SR hingga 99% dan untuk bolus SRS sebesar 95%. Nilai persentase perbedaan dosis permukaan antara perencanaan TPS dibandingkan dengan pengukuran dengan pesawat LINAC untuk bolus SR sebesar (29.4%, 12.6%, 9%, dan 26.8%) dan untuk bolus SR dengan campuran silika gel sebesar (29.4%, 27.9%, 13.4%, dan 17.2%). Berdasarkan diagram PSD dan data hasil pengukuran surface dose menunjukkan bahwa bolus SR dan SRS dapat meningkatkan nilai dosis permukaan seiring dengan bertambahnya ketebalan. Maka, dapat disimpulkan fabrikasi bolus SR dan SRS dapat dijadikan alternative pada perawatan radioterapi dalam penggunaan energi foton megavoltage.
================================================================
The surface dose is one of the important parameters in radiotherapy treatment, especially external radiation. In the use of photon files, additional material is required to increase the surface dose, such as bolus. In this study, the material used as a bolus is silicone rubber and silica gel with a thickness variation of 0.5, 1, and 1.5 cm. This study aims to find out the distribution of surface doses in bolus and know the surface dose value in cases of breast cancer post-mastectomy using photon energy 6 MV. The dose distribution test on the bolus with slab water phantom makes the surface doses increase along with bolus SR and bolus SR with a mixture of silica gel, increased surface dose on bolus SR up to 99%, and bolus SRS by 95%. The percentage value of surface dose difference between TPS planning and LINAC measurements for SR bolus (29.4%, 12.6%, 9%, and 26.8%) and bolus SR with silica gel mixtures of (29.4%, 27.9%, 13.4%, and 17.2%). PSD diagrams and surface dose measurement data show that bolus SR and SRS can increase the surface dose value as thickness increases. Thus, it can be concluded that the fabrication of bolus SR and SRS can be used as an alternative to radiotherapy treatment in the use of megavoltage photon energy.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Bolus, Dosis Permukaan, Film, Foton, Radiasi. Bolus, Film, Photon, Radiation, Surface Dose.
Subjects: Q Science > QC Physics
Q Science > QR Microbiology > QR 201.T84 Tumors. Cancer
Divisions: Faculty of Science and Data Analytics (SCIENTICS) > Physics > 45201-(S1) Undergraduate Thesis
Depositing User: Nurul Habibatul Jannah
Date Deposited: 13 Aug 2021 20:56
Last Modified: 13 Aug 2021 20:56
URI: http://repository.its.ac.id/id/eprint/86348

Actions (login required)

View Item View Item