Penyearah Tiga Fasa Terkontrol Untuk Aplikasi Charging Station Hybrid PV-GRID Berbasis FUZZY-PI Controller

Saputra, Ogie de Lahoya (2021) Penyearah Tiga Fasa Terkontrol Untuk Aplikasi Charging Station Hybrid PV-GRID Berbasis FUZZY-PI Controller. Undergraduate thesis, Intitute Teknologi Sepuluh Nopember.

[thumbnail of 07111740000114-Undergraduate_Thesis.pdf] Text
07111740000114-Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 October 2023.

Download (3MB) | Request a copy

Abstract

Kendaraan listrik atau kendaraan listrik hybrid menggunakan baterai
sebagai penyimpanan energi listrik untuk sumber energi penggerak. Daya
yang dibutuhkan untuk kebutuhan motor listrik merupakan daya yang
besar, oleh karena itu optimasi dua sumber sangatlah penting agar dapat
memaksimalkan efisiensi. Sel surya dapat membantu proses pengisian
daya karena arus yang disalurkan adalah arus listrik DC dan sel surya
menghasilkan arus listrik DC. Namun karena sumber energi terbarukan
dalam hal ini adalah sel surya tidak memiliki kehandalan yang tinggi
dikarenakan faktor alam, maka masih dibutuhkan sumber listrik AC yang
berasal dari PLN yang disearahkan karena sumber listrik yang berasal dari
PLN merupakan arus AC. Namun proses penyearahkan akan
menimbulkan harmonisa yang akan mengganggu sistem ditribusi dari
PLN. Untuk mengatasi masalah ini, Sistem Kendali Penyearah Tiga Fasa
menggunakan metode Fuzzy-PI dapat mengurangi harmonisa. Metode ini
menggunakan kombinasi controller Fuzzy dan PI untuk mengurangi
harmonisa yang terjadi. Oleh karena itu dengan adanya Sistem Kendali
Penyearah Tiga Fasa menggunakan metode Fuzzy-PI diharapkan tidak
mengganggu sistem distribusi yang ada. Hal itu dibuktikan dengan berkurangnya nilai steady-state error sebesar 0,07% pada saat grid dan DG dalam konisi seimbang.
================================================================================================
Electrical vehicle or hybrid vehicle are using batteries as electrical energy
storage for energy source. The power required for an electric vehicle is a
large amount of power, therefore the optimization of two sources is very
important in the order to maximize efficiency. Solar cells or photovoltaic
can help the charging process because photovoltaic produce DC current.
However, because the renewable energy source, in this case solar cells,
does not have high reliability due to natural factor, so it is still necessary
to have an AC power source from PLN which need to rectified because
the electricity source from PLN is AC current. However, the rectification
process will causes harmonic that will disturb the distribution system from
the PLN. To solve this problem, the three phase rectifier control system
using the fuzzy-PI method hopefully can solved the harmonic problem.
This method uses the combination of a fuzzy and PI controller. Therefore,
this three phase rectifier controlled with fuzzy-PI are expected not to
interfere the existing distribution system.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Photovoltaic, three phase rectifier, Fuzzy-PI, sel surya, penyearah tiga fasa, fuzzy PI.
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK1007 Electric power systems control
T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK1056 Solar powerplants
Divisions: Faculty of Intelligent Electrical and Informatics Technology (ELECTICS) > Electrical Engineering > 20201-(S1) Undergraduate Thesis
Depositing User: Ogie de Lahoya Saputra
Date Deposited: 23 Aug 2021 04:41
Last Modified: 23 Aug 2021 04:41
URI: http://repository.its.ac.id/id/eprint/88854

Actions (login required)

View Item View Item