Optimasi Jaringan dan Analisis Peluang Penghematan Energi Sistem Distribusi Perumda Tirta Pakuan Kota Bogor

Aulia, Fira Riza (2021) Optimasi Jaringan dan Analisis Peluang Penghematan Energi Sistem Distribusi Perumda Tirta Pakuan Kota Bogor. Masters thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 6014201028-Master_Thesis.pdf] Text
6014201028-Master_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 October 2024.

Download (3MB) | Request a copy

Abstract

Pengembangan dan pengoptimalan sistem perlu dilakukan untuk mencapai target cakupan pelayanan 100%. Selain itu dapat dilakukan penurunan biaya operasional dengan mengurangi konsumsi energi. Optimasi pelayanan dapat dilakukan dengan mengevaluasi jaringan distribusi air minum eksisting untuk mengetahui permasalahan pada desain terbangun terkait kecepatan aliran air dan tekanan. Audit kinerja pompa dilakukan untuk mengetahui efisiensi operasional pompa. Penelitian ini bertujuan untuk menganalisis permasalahan yang ada pada jaringan distribusi dan kinerja pompa sehingga dapat diberikan rekomendasi perbaikan apabila jaringan distribusi belum optimum. Selain itu, dihitung peluang penghematan yang dapat dilakukan serta kebutuhan biaya untuk menjalankan rekomendasi.
Penelitian ini menggunakan metode penelitian deskriptif dengan pendekatan metode penelitian survei dan studi kasus. Hasil data primer dan sekunder kemudian diolah terkait analisis jaringan perpipaan eksisting menggunakan program EPANET 2.2 dan dilakukan evaluasi efisiensi pompa untuk mengetahui kinerja pompa yang digunakan. Selanjutnya diberikan rekomendasi teknis sesuai dengan kriteria desain. Berdasarkan hasil rekomendasi perbaikan yang diberikan, dilakukan perhitungan terkait peluang penghematan energi yang dapat dilakukan dan kebutuhan biaya yang diperlukan untuk rekomendasi perbaikan.
Hasil analisis jaringan secara keseluruhan sudah cukup optimum. Masih banyak dengan nilai kecepatan aliran di bawah nilai standar minimum karena ditujukan untuk menampung proyeksi pengembangan pelanggan kedepannya. Efisiensi pompa wilayah pelayanan I pada jam puncak adalah 38,41%, pada jam minimum sebesar 21,68% dan pada rata-rata pemakaian sebesar 31,6%. Sedangkan efisiensi pompa wilayah pelayanan II pada jam puncak, jam minimum dan rata-rata pemakaian secara berurut adalah 53,23%, 30,70%, dan 47,13%. Nilai parameter kelistrikan (tegangan, arus, dan frekuensi) masih sesuai dengan desain pompa serta faktor daya ≥ 0,85. Rekomendasi pada pompa dilakukan penggantian pompa pada wilayah pelayanan I sehingga menghemat biaya listrik sebesar Rp 842.089 setiap bulannya dengan nilai Benefit Cost Ration (BCR) dari investasi sebesar 1,04 dan Payback Period selama 9 tahun 5 bulan. Sedangkan pada pompa wilayah pelayanan II dilakukan perbaikan mekanis pompa dan pengaturan ulang VSD sehingga dapat menghemat biaya listrik sebesar Rp 968.881 setiap bulannya.
================================================================================================
System development and optimization needed to be done to achieve 100% service coverage target. Operational costs could be reduced by minimizing energy consumption. Service optimization could be done by evaluating the existing drinking water distributin network to find out problems in the built design related to water flow velocity and pressure. Pump performance audits were conducted to determine pump operational efficiency. This study aimed to analyze the problems that exist in the distribution network and pump performance so that recommendations for improvements could be given if the distribution network was not optimum. Moreover, the savings opportunities that could be made as well as the cost requirements.
This study used descriptive research method with a survey research method approach and case studies. The results of the primary and secondary data obtained were then processed related to the analysis of the existing piping network using EPANET 2.2 program and an evaluation of the pump efficiency was carried out to determine the performance of the pump used. Furthermore, technical recommendations were given according to the design criteria. Based on the results of the improvement given, calculations were made regarding the energy saving opportunities that could carried out and the cost requirements needed.
The results of the overall network analysis were quite optimum. However, there were still many pipes with velocity values below the minimum standard value due to accommodating future customer development projections. The pump efficiency of service area I at peak hours was 38.41%, at minimum hours it was 21.68% and at an average usage of 31.6%. The pump efficiency of service area II at peak hours, minimum hours, and average usage were 53.23%, 30.70%, and 47.13% respectively. The electrical parameter values (voltage, current, and frequency) were still in accordance with the pump design and the power factor was ≥ 0.85. The recommendation was to replace the pump in service area I so that it saved electricity costs of Rp 842,089 per month with Benefit Cost Ratio (BCR) value of 1.04 investment and a Payback Period of 9 years and 5 months. Meanwhile, in service area II pump, mechanical repair of pump and VSD reset were carried out to save electricity costs of Rp 968,881 every month.

Item Type: Thesis (Masters)
Uncontrolled Keywords: Energy, Distribution Network, Optimization, Pump Efficiency, Energi, Jaringan Distribusi, Optimasi, Efisiensi Pompa
Subjects: T Technology > TD Environmental technology. Sanitary engineering > TD481 Water distribution systems
Divisions: Faculty of Civil, Planning, and Geo Engineering (CIVPLAN) > Environmental Engineering > 25101-(S2) Master Thesis
Depositing User: Fira Riza Aulia
Date Deposited: 14 Jan 2022 05:45
Last Modified: 14 Jan 2022 05:45
URI: http://repository.its.ac.id/id/eprint/92292

Actions (login required)

View Item View Item