Arifianto, Ivan Dwi (2022) Telemonitoring Sinyal EKG Pasien Berbasis Browser. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.
![]() |
Text
07311640000036-Undergraduate_Thesis.pdf - Accepted Version Restricted to Repository staff only Download (2MB) | Request a copy |
![]() |
Text
07311640000036-Undergraduate_Thesis.pdf - Accepted Version Restricted to Repository staff only until 1 April 2022. Download (2MB) | Request a copy |
Abstract
Telemonitoring adalah cara kesehatan mengadopsi penerapan internet, dengan telemonitoring mengurangi kemacetan rumah sakit dan meningkatkan pemanfaatan sumber daya medis. Tidak jarang kita menemukan data rekam medis hanya bisa diakses pada rumah sakit terkait. Padahal ada beberapa penyakit jantung yang perlu dilakukan diagnosis yang akurat dan cepat seperti penderita penyakit jantung. Untuk tujuan ini, pemantauan terus menerus dari sinyal jantung / elektrokardiogram dan aktivitas jantung pasien diperlukan. Pada penelitian ini, kami mengembangkan model pemantauan sinyal jantung yang bisa diakses di tempat lain, penelitian ini menggunakan metode kuantitatif dari 3 jenis sinyal yang dibuat oleh function generator. Sinyal sinus, sinyal kotak, dan sinyal segitiga diberikan kepada hardware mikrokontroler Nodemcu Esp8266 untuk diolah dan dikirim ke dalam database server. Proses yang dilakukan mikrokontroler adalah perekaman dan pengiriman, sehingga saat melaukan pengiriman, perekaman dihentikan sementara, dari proses ini terjadi perbedaan jumlah data. Data yang telah dikirim ditampilkan pada layar browser kemudian dibandingkan dengan data sebelum pengiriman melalui bentuk grafik yang ditampilkan pada layar osiloskop. Dari 3 jenis sinyal yang diterima didapatkan 6 data dengan nilai rata-rata dan standar deviasi yang berbeda. Pada sinyal sinus didapatkan nilai rata-rata sebesar 66,76±25,47 mV untuk pengiriman pertama dan 145,925±76,45 mV untuk pengiriman kedua, kemudian untuk sinyal kotak didapatkan nilai standar deviasi sebesar 329,45±0,49 mV untuk pengiriman pertama dan 38,85±51,27 mV untuk pengiriman kedua, terakhir untuk sinyal segitiga didapatkan nilai standar deviasi sebesar 186,25±61,55 mV dan 117,575±59,61 mV untuk pengiriman kedua.
======================================================================================================
Telemonitoring is a way of health adopting the application of the internet, with telemonitoring reducing hospital congestion and increasing the utilization of medical resources. Not infrequently we find medical record data can only be accessed at the related hospital. Even though there are some heart diseases that need to be diagnosed accurately and quickly, such as people with heart disease. For this purpose, continuous monitoring of cardiac signals/electrocardiogram and cardiac activity of the patient is required. In this study, we developed a model of cardiac signal monitoring that can be accessed elsewhere, this study uses a quantitative method of 3 types of signals generated by a function generator. The sine signal, square signal, and triangle signal are given to the Nodemcu Esp8266 microcontroller hardware to be processed and sent to the database server. The process carried out by the microcontroller is recording and sending, so that when sending, recording is paused, from this process there is a difference in the amount of data. The data that has been sent is displayed on the browser screen and then compared with the data before sending through the form of a graph displayed on the oscilloscope screen. From the 3 types of signals received, 6 data are obtained with different means and standard deviations. In the sine signal, the standard deviation value is 66.76±25,47 mV for the first delivery and 145.925±76,45 mV for the second delivery, then for the box signal, the standard deviation value is 329.45±0.49 mV for the first delivery. and 38.85±51.27 mV for the second delivery, lastly for the triangular signal, the standard deviation values were 186.25±61.55 mV and 117.575±59.61 mV for the second delivery.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | Telemonitoring, Elektrokardiogram (EKG) |
Subjects: | R Medicine > RC Internal medicine > RC683.5.E5 Electrocardiography R Medicine > RT Nursing > RT89 Nursing services--Administration. |
Divisions: | Faculty of Intelligent Electrical and Informatics Technology (ELECTICS) > Biomedical Engineering > 11410-(S1) Undergraduate Thesis |
Depositing User: | Ivan Dwi Arifianto |
Date Deposited: | 19 Feb 2022 07:05 |
Last Modified: | 19 Feb 2022 07:05 |
URI: | http://repository.its.ac.id/id/eprint/94504 |
Actions (login required)
![]() |