Identifikasi Unbalance Pada Centrifugal Fan C2322 Unit PA Pabrik 3 PT. Petrokimia Gresik Dengan Menggunakan Metode Pengukuran Vibrasi

Febrianto, Haryo (2018) Identifikasi Unbalance Pada Centrifugal Fan C2322 Unit PA Pabrik 3 PT. Petrokimia Gresik Dengan Menggunakan Metode Pengukuran Vibrasi. Diploma thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 2114030029-Non_Degree.pdf]
Preview
Text
2114030029-Non_Degree.pdf - Accepted Version

Download (6MB) | Preview

Abstract

Predictive maintenance merupakan salah satu teknik dari
perawatan yang berbasis pada kondisi mesin atau yang biasa
disebut condition-based maintenance. Analisis vibrasi adalah
salah satu metode yang digunakan dalam predictive maintenance,
digunakan untuk mengawasi dan menganalisa kondisi kritis dari
mesin, komponen, dan sistem pada bagian tertentu berbasis getaran
atau vibrasi yang ditimbulkan benda tersebut. Pada centrifugal fan
sering ditemui kasus vibrasi yang melebihi batas standart yang
disebabkan oleh banyak faktor. Untuk itu diperlukan sistem
monitoring berbasis vibrasi untuk mendeteksi kerusakan pada
centrifugal fan.
Dalam penelitian ini dilakukan pengukuran getaran untuk
mengetahui level getaran yang dihasilkan sesuai standart ISO
10816 dan selanjutnya dilakukan analisa spektrum getaran untuk
mendeteksi jenis kerusakan yang terjadi. Setelah diketahui jenis
kegagalan yang terjadi maka didapatkan solusi untuk mengatasi
kegagalan tersebut. Setelah proses perbaikan selesai, dilakukan
pengukuran getaran ulang untuk memastikan bahwa centrifugal
fan berada pada level getaran yang aman untuk digunakan.
Berdasarkan hasil pengukuran yang dilakukan, maka dapat
dibandingkan antara level getaran sebelum dilakukan proses
balancing dan juga data setelah dilakukan proses balancing.
Setelah proses balancing, didapatkan penurunan nilai amplitude,
yaitu untuk titik MOH dari 8.91 mm/s menjadi 2.1 mm/s. Untuk titik MOV dari 5.1 mm/s menjadi 2.3 mm/s. Untuk titik MOA dari
6,0 mm/s menjadi 1,3 mm/s. Untuk titik MIH dari 10,0 mm/s
menjadi 1,8 mm/s. Untuk titik MIV 3,2 mm/s menjadi 1,2 mm/s.
Untuk titik MIA dari 6,5 mm/s menjadi 2,5 mm/s. Untuk titik FIH
dari 8,3 mm/s menjadi 1,9 mm/s. Untuk titik FIV dari 3,1 mm/s
menjadi 1,1 mm/s. Untuk titik FIA dari 4,5 mm/s menjadi 1,3
mm/s. Untuk titik FOH dari 12,3 mm/s menjadi 1,8 mm/s. Untuk
titik FOV dari 5,2 mm/s menjadi 2,7 mm/s. Untuk titik FOA dari
5,1 mm/s menjadi 1,2 mm/s.
==========================================================================================================
Predictive maintenance is one of the maintenance
techniques based on the condition of the machine or commonly
called condition-based maintenance. Vibration analysis is one of
the methods used in predictive maintenance, used to monitor and
analyze critical conditions of machinery, components, and systems
on certain parts based on the vibration of the object. Some
vibration cases often encountered on the centrifugal fan that
exceed the standard limit caused by multiple factors. This requires
a vibration-based monitoring system to detect damage on the
centrifugal fan.
In this research, vibration measurement is done to find out
the level of vibration generated according to ISO 10816 standard
and then to be analyzed with vibration spectrum to detect the type
of damage happened. After knowing the type of failure that occurs,
then it is obtained the solution to overcome it. After repairment
process is completed, repeated vibration measurements are done
to ensure that the centrifugal fan is at a safe vibration level to use.
Based on the measurement results, it can be compared
between the vibration level before the balancing process and also
the data after the balancing process. After balancing process,
lower amplitude value is obtained, for MOH point from 8,9 mm/s
to 2,1 mm/s. For point MOV from 5.1 mm/s to 2.3 mm/s. For point MOA from 6,0 mm/s to 1,3 mm/s. For point MIH from 10,0 mm/s
to 1,8 mm/s. For point MIV 3,2 mm/s to 1,2 mm/s. For point MIA
from 6,5 mm/s to 2,5 mm/s. For point FIH from 8,3 mm/s to 1,9
mm/s. For point FIV from 3,1 mm/s to 1,1 mm/s. For point FIA
from 4,5 mm/s to 1,3 mm/s. For point FOH from 12,3 mm/s to 1,8
mm/s. For point FOV from 5,2 mm/s to 2,7 mm/s. For point FOA
from 5,1 mm/s to 1,2 mm/s.

Item Type: Thesis (Diploma)
Additional Information: RSMI 621.811 Feb i-1 3100018074445
Uncontrolled Keywords: analisis vibrasi, unbalance, prediktif maintenance
Subjects: T Technology > TA Engineering (General). Civil engineering (General) > TA355 Vibration.
T Technology > TJ Mechanical engineering and machinery > TJ217.6 Predictive Control
Divisions: Faculty of Vocational > Mechanical Industrial Engineering
Depositing User: Haryo Febrianto
Date Deposited: 01 Mar 2018 02:34
Last Modified: 10 Jul 2020 02:49