Insiden kebakaran di Kota Surabaya kian meningkat setiap tahunnya. Penyebab utamanya diantaranya adalah akibat hubungan pendek arus listrik. Meskipun listrik merupakan kebutuhan sehari-hari, penggunaan listrik juga dapat menyebabkan bahaya kepada penggunanya jika tidak diperlakukan dengan baik. Salah satu bahaya yang sering terjadi dan menimbulkan kejadian kebakaran adalah peristiwa busur api. Busur api yang sering terjadi tanpa kita sadari adalah busur api seri yang terjadi di dalam selubung isolasi kabel. Maka dari itu, diperlukan sebuah analisa bahaya busur api listrik pada tegangan rendah sehingga keamanan para pengguna jasa listrik dapat tetap terjaga. Arus Arc flash pada tegangan rendah memiliki karakteristik berupa bentuk gelombang yang nilainya tinggi, namun durasi yang relative singkat. Hal ini berakibat pada tidak bereaksinya alat pengaman dalam mengatasi gangguan ini. Dalam tugas akhir kali ini, penulis akan membuat sebuah pemodelan terhadap hambatan arcing pada tegangan rendah. Pemodelan ini menggunakan metode Jaringan Saraf Tiruan yang berfungsi untuk membentuk karakteristik dari bentuk arc flash dengan menentukan nilai hambatan pada tempat terjadinya arcing. Pemodelan dilakukan berdasarkan kasus arc flash pada dua buah elektroda yang dipasang secara seri dalam rangkaian sistem tegangan rendah, dengan variabel beban berbeda-beda. Keluaran dari tugas akhir ini adalah sebuah hambatan arcing pemodelan yang mempunyai nilai MSE < 0,05 jika dibandingkan dengan hambatan arcing hasil percobaan di laboratorium.
===============================================================================================
The fire accident in Surabaya is increasing every year. The majority issues was due to short circuit. Even though electricity is useful and needed for every days use, electricity use can cause harm to its user if not treated properly. One of the dangers that often happened and resulting fire is the arc flash phenomenon. Arc flash that happened often without our knowing was the series arc flash that happened inside di insulation cable. Therefore, we need an analysis of the arc flash phenomenon at the lower voltage so that the electrical security of its user can be maintained. Arc flash currents at low voltages characterized by a waveform whose value is high, but relatively short duration. This resulted in not reacting safety device in overcoming this disorder. In this final project, the author will make a model of the arcing resistance at low voltage. This modeling method is Artificial Neural Network which serves to establish the characteristics of arc flash with determining the value of resistance at the scene of the arcing. The modelling is on a case of arc flash on two electrode located series in the low voltage electrical circuit system with variable loads. The output of this thesis is an arcing resistance modelling that have MSE value < 0,05 compared to the arcing resistance results that taken with the experiment in the laboratory.

Item Type: Thesis (Undergraduate)
Additional Information: RSE 621.317 Asa a-1 2019
Uncontrolled Keywords: Pemodelan, Busur Api, Tegangan Rendah, Jaringan Saraf Tiruan
Subjects: Q Science > QA Mathematics > QA76.87 Neural networks (Computer Science)
T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK2861 Electric relays
Divisions: Faculty of Electrical Technology > Electrical Engineering > 20201-(S1) Undergraduate Thesis