Studi Penerapan SNI 1726:2019 Dengan Retrofit Pada Modifikasi Gedung Apartemen Taman Melati Surabaya Di Wilayah Zona Rawan Gempa Bumi

Bastian, Agus (2021) Studi Penerapan SNI 1726:2019 Dengan Retrofit Pada Modifikasi Gedung Apartemen Taman Melati Surabaya Di Wilayah Zona Rawan Gempa Bumi. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 03111740000021-Undergraduate_Thesis.pdf] Text
03111740000021-Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 April 2023.

Download (8MB) | Request a copy

Abstract

Dalam tugas akhir ini akan dilakukan studi terkait penerapan gaya gempa SNI 1726:2019 terhadap struktur yang direncanakan dengan SNI 1726:2012 untuk mengetahui kebutuhan perkuatan dalam memenuhi standar bangunan yang ada. Perkuatan struktur umumnya bertujuan untuk mengembalikan atau meningkatkan kekuatan elemen struktur agar mampu menahan beban sesuai rencana. Salah satu cara perkuatan struktur bisa dilakukan adalah penyelubungan dengan material ringan komposit yaitu Carbon Reinforced Fiber Polymer (CFRP),adalah serat karbon yang didefinisikan sebagai serat yang mengandung setidaknya 90% berat karbon (Alberto, 2013). CFRP lebih murah dan mudah dilakukan dalam pelaksanaannya di lapangan karena tidak perlu membongkar elemen struktur eksisting sehingga dapat mempercepat pengerjaan konstruksinya (Pangestuti, Nuroji, Antonius, 2006
Pada tugas akhir ini akan dilakukan perencanaan ulang Apartemen Taman Melati Surabaya yang dimodifikasi menjadi 12 lantai dan direncanakan ulang dengan SNI 1726:2012 dan SNI 2847:2013 yang kemudian akan dievaluasi dengan SNI 1726:2019 dan akan dilakukan perkuatan dengan CFRP apabila kapasitas dari elemen belum memenuhi beban yang diberikan.
Elemen struktur didesain dengan mutu beton 35 MPa dan 25 MPa serta mutu baja 420 MPa dengan dimensi ketebalan pelat 130 mm , balok anak ukuran 300 x 500 ,balok induk ukuran 400 x 600 , dengan 3 jenis kolom dengan ukuran 500 x 500 , 600 x 600 dan 750 x 750 , dan 2 jenis dinding geser dengan tebal 230 mm. Pondasi direncanakan secara plastis dengan spun pile D600 dan D800 dengan 3 jenis pilecap
Dari hasil analisis dengan SNI 1726:2019 terdapat peningkatan parameter gempa sebesar 6.15% untuk SDS dan 15% untuk SD1 , sehingga terdapat peningkatan koefisien Cs sebesar 15.5% Terdapat peningkatan simpangan struktur untuk arah x sebesar 37% dan arah y sebesar 38%. Untuk peningkatan gaya dalam rata-rata adalah 18.38% untuk balok induk , 21.6% untuk kolom dan 14.84% untuk shearwall. Akibat dari peningkatan tersebut beberapa elemen balok diperkuat dengan CFRP dengan jumlah berkisar antara 1-6 plate per elemen

Kata-kata kunci : Retrofit , Carbon Fiber Reinforced Polymer
=====================================================================================================

In this final project, studies will be carried out related to the application of the SNI 1726:2019 regarding structures planned with SNI 1726: 2012 to determine the need for retrofitting in meeting existing building standards. Strengthening of structures generally aims to restore or increase the strength of structural elements in order to be able to withstand loads as planned. One of the method of structural strengthening can be done is by covering it with a lightweight composite material, namely ,Carbon Reinforced Fiber Polymer (CFRP) is a carbon fiber that contains at least 90% by weight of carbon (Alberto, 2013). CFRP is cheaper and easier to carry out in the field because there is no need to dismantle existing structural elements so that it can speed up construction work (Pangestuti, Nuroji, Antonius, 2006
In this final project, the Taman Melati Surabaya Apartment will be redesigned which is modified into 12 floors and re-planned with SNI 1726: 2012 and SNI 2847: 2013 which will then be evaluated with SNI 1726: 2019 and will be strengthened with CFRP if the capacity of the elements do not meet the load specified.
The structural elements are designed with concrete strengths of 35 MPa and 25 MPa and steel grades of 420 MPa with plate thickness of 130 mm, secondary beam of 300 x 500, main beam of 400 x 600, with 3 types of columns with sizes of 500 x 500, 600 x 600 and 750 x 750, and 2 types of shear walls with a thickness of 230 mm. The foundation is planned plastically with spun pile D600 and D800 with 3 types of pilecap
From the analysis of SNI 1726:2019, there is an increase in earthquake parameters by 6.15% for SDS and 15% for SD1, so there is an increase in the Cs coefficient of 15.5%. There is also an increase in structural displacements for the x direction by 37% and the y direction by 38%. The average increase in internal forces was 18.38% for beam, 21.6% for column and 14.84% for shearwalls. As a result of this increase, several beam elements were reinforced with CFRP in the range of 1-6 plates per element.

Keyword : Retrofit , Carbon Fiber Reinforced Polymer

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Retrofit , Carbon Fiber Reinforced Polymer
Subjects: T Technology > TA Engineering (General). Civil engineering (General) > TA444 Reinforced concrete
Divisions: Faculty of Civil, Environmental, and Geo Engineering > Civil Engineering > 22201-(S1) Undergraduate Theses
Depositing User: Agus Bastian
Date Deposited: 25 Feb 2021 03:46
Last Modified: 25 Feb 2021 03:46
URI: http://repository.its.ac.id/id/eprint/82814

Actions (login required)

View Item View Item