Abstract

Pengujian getar pada komponen mekanikal secara umum dilakukan terhadap satu sumbu utama, pada arah horizontal ataupun vertikal saja. Padahal, yang terjadi pada kondisi aktual, getaran yang terjadi pada sebuah sistem timbul pada beberapa sumbu, dimana pengujian harus dilakukan mendekati dengan kondisi aktual kerja saat komponen digunakan.
Dalam penelitian ini membahas mengenai perancangan dan fabrikasi alat dari konsep mekanisme vibration exciter yang menghasilkan getaran mekanik paksa yang ditimbulkan oleh adanya putaran massa unbalance dengan resultan arah getar pada sumbu horizontal dan vertikal yaitu Dual Translational Shaking Table (DTST). Penelitian ini juga menganalisa mengenai respon dinamis Dual Translational Shaking Table (DTST) terhadap variasi massa unbalance dan frekuensi input.
Pengujian Dual Translational Shaking Table (DTST) dilakukan dengan merakit DTST sebagai objek yang akan diuji respon dinamisnya terhadap variasi massa unbalance 400gr, 800gr, dan 1200gr. Pengambilan data juga dilakukan dengan input frekuensi yang bersumber dari motor AC ¼ Hp, sebagai input parameter frekuensi yang akan diuji pada rentang frekuensi 7 hingga 15 Hz. Diperlukan juga pemasangan sensor percepatan (akselerometer probe) pada objek yang bergetar yang berfungsi mengukur percepatan pada objek yang bergerak. Outputan dari akselerometer menjadi input pada oscilosscope guna menampilkan grafik respon dinamis percepatan DTST.
Hasil dari penelitian Tugas Akhir ini, yaitu telah dirancang dan dibangun alat untuk pengujian komponen mechanical, batterypack, dan komponen lainnya untuk skala laboratorium berupa Dual Translational Shaking Table (DTST) dan didapatkan hasil berupa grafik respon percepatan terhadap perubahan frekuensi input serta data yang didapat dari pengujian memiliki kesamaan karakteristik dengan nilai error toleransi sebesar 15% dengan data hasil simulasi dengan permodelan matematis. Pada hasil perhitungan dan simulasi didapatkan frekuensi natural terdapat pada frekuensi 3.45 Hz pada sumbu horizontal dan 5.98 Hz pada sumbu vertikal. Frekuensi kerja yang digunakan adalah rentang 7-15 Hz sehingga alat aman untuk digunakan karena tidak melewati rentang dua frekuensi naturalnya. Grafik dari hasil percobaan merepresentasikan bahwa semakin besar massa unbalance yang diberikan maka akan berpengaruh semakin besar pula respon percepatannya berbanding lurus. Sedangkan untuk frekuensi memiliki pengaruh fungsi kuadrat terhadap respon percepatan.
=====================================================================================================

Vibration testing on mechanical components is generally carried out on one main axis, in the horizontal or vertical direction only. In fact, in actual conditions, vibrations can occur in a system on several axes, where the test must be carried out close to the actual working conditions when the components are used.
In this study, it discusses the design and fabrication of testing tool that using the concept of the vibration exciter mechanism which produces forced mechanical vibrations caused by unbalance mass rotation with the resultant vibration direction (horizontal and vertical axes), namely the Dual Translational Shaking Table (DTST). This study also analyzes the dynamic response of the Dual Translational Shaking Table (DTST) to variations in mass unbalance and input frequency.
Dual Translational Shaking Table (DTST) testing is done by assembling the DTST as an object to be tested for its dynamic response to unbalance mass variations of 400gr, 800gr, and 1200gr. Data retrieval is also carried out by inputting the frequency from the AC motor ¼ Hp, as input for the frequency parameter to be tested in the frequency range 7 to 15 Hz. It is also necessary to install an acceleration sensor (accelerometer probe) on a vibrating object which functions to measure the acceleration of a moving object. The output from the accelerometer becomes input on the oscilloscope to display a graph of the dynamic response of the DTST acceleration.
The results of this Final Project research, which has been designed and built a tool for testing mechanical components, battery pack, and other components for laboratory scale in the form of a Dual Translational Shaking Table (DTST) and the results obtained in the form of acceleration response graphs to changes in input frequency and data The test has the same characteristics with an error tolerance value of 15% with the simulation results data with mathematical modeling. In the results of calculations and simulations, it is found that the natural frequency is 3.45 Hz on the horizontal axis and 5.98 Hz on the vertical axis. The working frequency used is in the range of 7-15 Hz so that the tool is safe to use because it does not pass through its two natural frequency ranges. The graph of the experimental results shows that the greater the unbalance mass given, the greater the acceleration response is proportional. Meanwhile, frequency has the influence of the quadratic function on the acceleration response.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Permodelan dinamis, frekuensi natural, frekuensi input, massa unbalance, Dynamic modelling, natural frequency, input frequency.
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ230 Machine design
Divisions: Faculty of Industrial Technology and Systems Engineering (INDSYS) > Mechanical Engineering > 21201-(S1) Undergraduate Thesis