Analisis Penampang Kolom Beton Bertulang Menggunakan Visual Basic 6.0 Dengan Memperhitungkan Efek Pengekangan

Tirtajaya, Recky (2008) Analisis Penampang Kolom Beton Bertulang Menggunakan Visual Basic 6.0 Dengan Memperhitungkan Efek Pengekangan. Other thesis, Institut Teknologi Sepuluh Nopember Surabaya.

[thumbnail of 3104100012-Undregraduate_Thesis.pdf] Text
3104100012-Undregraduate_Thesis.pdf - Accepted Version

Download (21MB)

Abstract

Perkembangan teknologi konstruksi dewasa ini terutama konstruksi beton bertulang seringkali menuntut penggunaan elemen-elemen struktur yang berkinerja tinggi dan daktail, Hai ini disebabkan oleh beberapa kasus keruntuhan bangunan karena gempa yang terjadi akhir-akhir ini. Untuk mencegah keruntuhan mendadak suatu struktur, perencanaan kolom beton bertulang yang berfungsi sebagai penahan gaya gempa harus diperhatikan dengan seksama. Perencanaan kolom selama ini didasarkan pada perilaku tegangan-regangan beton tak terkekang (pendekatan penyederhanaan blok stress), padahal dengan adanya tulangan baja pengekang akan sangat berpengaruh pada kapasitas nominal kolom, terutama pada daerah kontrol tekan. Untuk menganalisa efek (pengaruh) pengekangan lateral terhadap penambahan kapasitas kolom, maka dilakukan suatu studi terhadap penampang kolom beton bertulang yang terkekang. Karena perhitungan yang cukup rumit dengan iterasi yang panjang, maka dibutuhkan suatu program komputer sebagai alat bantu. Untuk mencapai tujuan penelitian/studi ini, sebuah program sederhana dikembangkan dengan memakai bahasa pemrograman Visual Basic 6.0. Program bantu ini dinamakan ConfinedCOL v.1, dan dapat diaplikasikan untuk kolom berpenampang bujursangkar (square) dengan tulangan pada empat sisi dan dua sisi. Program ini dapat digunakan baik untuk beton mutu normal (NSC) maupun beton mutu tinggi (HSC). Pemodelan hubungan tegangan-regangan beton terkekang yang diadopsi di dalam studi ini antara lain Kent-Park (1971), SheikhUzumeri (1982), Mander-Priestley (1988), Yong-Nawy (1988), CussonPaultre (1995), Diniz-Frangopol (1997), Kappos-Konstantinidis (1999), Hong-Han (2005) dan Kusuma-Tavio (2008). Hasil yang diperoleh dari semua pemodelan tersebut telah diuji keakuratannya. Dari studi ini dapat disimpulkan bahwa pengekangan lateral akan mempengaruhi bentuk kurva tegangan regangan beton. Perubahan ini jelas terlihat dari nilai tegangan puncak, regangan puncak dan regangan ultimatenya. Perubahan bentuk kurva ini selanjutnya akan mempengaruhi luas area desak beton yang berada di bawah kurva tegangan-regangan, yang tentunya akan manambah besarnya gaya tekan beton (Cc). Penambahan nilai Cc akan berpengaruh pada penambahan kapasitas kolom. Dari hasil studi ini diketahui bahwa ada enam faktor utama yang paling menentukan efektifitas pengekangan yaitu diameter sengkang, spasi antar sengkang, mutu baja tulangan sengkang, konfigurasi sengkang, jumlah dan ukuran tulangan longitudinal serta konfigurasi tulangan longitudinal. Studi parametrik dilakukan dengan maksud membandingkan tingkat efektifitas masing-masing parameter tersebut. Dari hasil perbandingan, dapat disimpulkan bahwa parameter yang paling berpengaruh terhadap penambahan kapasitas nominal kolom adalah spasi antar sengkang
======================================================================================================================================
The development of construction technology today, especially reinforced concrete construction, often requires the use of high-performance and ductile structural elements. This is due to several cases of building collapse due to recent earthquakes. To prevent sudden collapse of a structure, the planning of reinforced concrete columns which function as earthquake force resistors must be carefully considered. Column planning has so far been based on the stress-strain behavior of unconfined concrete (simplified stress block approach), even though the presence of confining steel reinforcement will greatly influence the nominal capacity of the column, especially in the compression control area. To analyze the effect (influence) of lateral restraints on increasing column capacity, a study was carried out on the cross-section of confined reinforced concrete columns. Because the calculations are quite complicated with long iterations, a computer program is needed as a tool. To achieve the objectives of this research/study, a simple program was developed using the Visual Basic 6.0 programming language. This auxiliary program is called ConfinedCOL v.1, and can be applied to square-section columns with reinforcement on four sides and two sides. This program can be used for both normal quality concrete (NSC) and high quality concrete (HSC). Modeling of confined concrete stress-strain relationships adopted in this study include Kent-Park (1971), Sheikh Uzumeri (1982), Mander-Priestley (1988), Yong-Nawy (1988), Cusson Paultre (1995), Diniz-Frangopol ( 1997), Kappos-Konstantinidis (1999), Hong-Han (2005) and Kusuma-Tavio (2008). The results obtained from all modeling have been tested for accuracy. From this study it can be concluded that lateral restraint will influence the shape of the concrete stress strain curve. This change is clearly visible from the values of peak stress, peak strain and ultimate strain. Changes in the shape of this curve will then affect the area of concrete compression under the stress-strain curve, which of course will increase the magnitude of the concrete compression force (Cc). Increasing the Cc value will have an effect on increasing the column capacity. From the results of this study, it is known that there are six main factors that most determine the effectiveness of restraints, namely the diameter of the stirrups, the spacing between stirrups, the quality of the stirrup reinforcing steel, the configuration of the stirrups, the number and size of longitudinal reinforcement and the configuration of longitudinal reinforcement. Parametric studies were carried out with the aim of comparing the level of effectiveness of each of these parameters. From the comparison results, it can be concluded that the parameter that has the most influence on increasing the nominal capacity of the column is the spacing between stirrups

Item Type: Thesis (Other)
Additional Information: RSS 624.183 425 Tir a-1 2008
Uncontrolled Keywords: ConfinedCOL v.l , diagram interaksi aksial-momen, efek pengekangan, kapasitas kolom, kurva tegangan-regangan, parameter pengekangan, Visual Basic 6.0; Axial-moment interaction diagram, column capacity, ConfinedCOL v.l, confinement effects, confinement parameters, stressstrain curves, Visual Basic 6.0
Subjects: T Technology > TA Engineering (General). Civil engineering (General) > TA444 Reinforced concrete
Divisions: Faculty of Civil Engineering and Planning > Civil Engineering > 22201-(S1) Undergraduate Thesis
Depositing User: EKO BUDI RAHARJO
Date Deposited: 07 May 2024 07:14
Last Modified: 07 May 2024 07:14
URI: http://repository.its.ac.id/id/eprint/107944

Actions (login required)

View Item View Item