Analisis Penentuan Lokasi Dan Penambahan Trafo AVR 20KV Untuk Memperbaiki Kualitas Tegangan, Rugi-Rugi Daya Dan Tekno Ekonomi Pada Penyulang Cartenz Di PLN ULP PRAFI

Firmansyah, Aris (2026) Analisis Penentuan Lokasi Dan Penambahan Trafo AVR 20KV Untuk Memperbaiki Kualitas Tegangan, Rugi-Rugi Daya Dan Tekno Ekonomi Pada Penyulang Cartenz Di PLN ULP PRAFI. Masters thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 6022241017-Master_Thesis.pdf] Text
6022241017-Master_Thesis.pdf

Download (12MB)

Abstract

Penyulang Cartenz di PLN ULP Prafi tepatnya di Gardu Hubung Prafi mengalami drop tegangan yaitu sebesar 17,6KV dan rugi daya sebesar 0,19MW. Untuk memperbaiki kondisi tersebut dilaksanakan simulasi penempatan Trafo AVR menggunakan Digsilent pada 3 titik pilihan dan hasil dari simulasi untuk titik terbaik adalah di titik C yaitu lokasi sebelum masuk GH Prafi dengan nilai tegangan menjadi 19,76 KV dan rugi daya sebesar 0,14 MW. Nilai rupiah yang bisa diselamatkan selama 20 Tahun sesuai lifetime Trafo AVR adalah Rp 12.655.572.000 dan nilai kWh yang bisa diselamatkan adalah sebesar 8.760.000 kWh. Dilakukan perhitungan analisis tekno ekonomi untuk proyek pada penelitian ini, yaitu menggunakan metode Benefit Cost Ratio (BCR) dengan hasil nilai 2,23 lebih besar dari 1, metode Net Present Value (NPV) dengan hasil nilai lebih besar dari nol, metode Internal Rate of Return (IRR) dengan hasil nilai lebih besar dari nilai MARR yang sudah ditentukan sebelumnya, dari hasil tersebut dapat disimpulkan bahwa proyek pemasangan Trafo AVR pada penelitian ini dinyatakan Layak untuk dilaksanakan. Sehingga secara teknis untuk proyek pemasangan Trafo AVR ini mengalami perbaikan nilai tegangan dan rugi daya serta secara analisis Tekno Ekonomi dinyatakan layak menggunakan 3 metode yang sudah dilaksanakan.
======================================================================================================================================
The Cartenz distribution network at PLN ULP Prafi specifically at the Prafi Substation experienced a voltage drop of 17.6 kV and a power loss of 0.19 MW. To address this issue, a simulation of AVR transformer placement was conducted using Digsilent at three selected locations. The simulation results indicated that the optimal location was Point C the site just before the Prafi Switching Station where the voltage stabilized at 19.76 kV and power loss was reduced to 0.14 MW. The rupiah savings over a 20 year period corresponding to the service life of the AVR transformer amount to Rp 12,655,572,000, and the kWh savings total 8,760,000 kWh. A techno economic analysis was conducted for the project in this study using the Benefit Cost Ratio (BCR) method, yielding a value of 2.23 greater than 1, the Net Present Value (NPV) method, yielding a value greater than zero; and the Internal Rate of Return (IRR) method, yielding a value greater than the previously determined Minimum Acceptable Rate of Return (MARR). Based on these results, it can be concluded that the AVR transformer installation project in this study is deemed feasible. Thus, from a technical standpoint, this AVR transformer installation project improves voltage stability and reduces power losses, and from a techno-economic analysis, it is deemed feasible based on the three methods applied.

Item Type: Thesis (Masters)
Uncontrolled Keywords: Jatuh Tegangan, Rugi Daya, Trafo AVR, Digsilent, Tekno Ekonomi, Benefit Cost Ratio (BCR), Net Present Value (NPV), Internal Rate of Return (IRR), Voltage Drop, Power Loss, AVR Transformer, Digsilent, Technological Economics, Benefit-Cost Ratio (BCR), Net Present Value (NPV), Internal Rate of Return (IRR)
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK2851 Voltage regulators.