Rancang Bangun Sistem Pengendalian Level Pada Tangki Pemanas Plant Fluidized Bed Reactor Pengolahan Oil Sludge

Wahyuningrum, Putri Merlisa (2017) Rancang Bangun Sistem Pengendalian Level Pada Tangki Pemanas Plant Fluidized Bed Reactor Pengolahan Oil Sludge. Diploma thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 2414031027-Non_Degree .pdf]
Preview
Text
2414031027-Non_Degree .pdf

Download (4MB) | Preview

Abstract

Kebutuhan energi yang besar, menyebabkan banyak perusahaan minyak dan gas meningkatkan aktifitas eksplorasi dan produksinya. Saat minyak diekplorasi dan diproduksi dari sumur, maka sludge akan ikut terbawa. Sludge merupakan limbah dari minyak mentah yang masih banyak mengandung pasir, tanah, dan serat-serat atau ampas yang terikut di dalam minyak. Salah satu proses pengambilan minyak pada sludge adalah memberikan steam pada sludge sehingga minyak bisa terlepas dari sludge dan larut di dalam uap air. Untuk proses tersebut diperlukan pengendalian level untuk menjaga ketinggian fluida pada tangki pemanas agar didapatkan steam yang sesuai. Sistem pengendalian ini menggunakan sensor level switch dan mikrokontroller ATmega 32 sebagai kontroller. Aktuator yang digunakan berupa motor servo. Hasil respon sistem proses tersebut pada open loop, dapat dilihat bahwa proses tersebut memerlukan controler untuk menjamin agar proses dapat berjalan dengan baik. Pada closed loop, dapat diketahui bahwa sistem dari tangki pemanas membutuhkan pengendalian agar dapat menjaga set point sebesar 10 cm dengan rise time sebesar 22,52 sekon dan pada uji disturbance diketahui bahwa performansi pengendali tersebut dalam mempertahankan set point terhadap perubahan dengan baik.
===============================================================================================================================
Large energy needs, causing many oil and gas companies to increase their exploration and production activities. When oil explored and produced from well, sludge will be carried along. Sludge is a waste of crude oil that still contains a lot of sand, soil, and fibers or pulp in oil. One of the process of taking oil in sludge is to provide steam to sludge so that oil can be released from sludge and dissolve in water vapor. For this process level control is required to maintain the height of the fluid in the heating tank to obtain the appropriate steam. This control system uses Level Switch sensors and ATmega 32 microcontroller as a controller. The actuator used is a servo motor. The results of the process system response to the open loop, can be seen that the process requires a controller to ensure that the process can run well. In the closed loop, it can be seen that the system of the heating tank requires control in order to maintain the set point value is 10 cm with the rise time of 22.52 seconds and on the disturbance test it is known that the performance of the controller in maintaining the set point to change well.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Sistem Pengendalian Level, Open Loop, Closed Loop, Disturbance
Subjects: T Technology > TP Chemical technology > TP156 Crystallization. Extraction (Chemistry). Fermentation. Distillation. Emulsions.
Divisions: Faculty of Industrial Technology > Physics Engineering > (D3) Diploma 3
Depositing User: Wahyuningrum Putri Merlisa
Date Deposited: 14 Nov 2024 01:58
Last Modified: 14 Nov 2024 01:58
URI: http://repository.its.ac.id/id/eprint/46922

Actions (login required)

View Item View Item