Janah, Nur Rima Samarotul (2017) Analisa Unjuk Kerja Heat Recovery Steam Generator (HRSG) dengan Menggunakan Pendekatan Porous Media di PLTGU - Jawa Timur. Other thesis, Sepuluh Nopember Institute of Technology.
Preview |
Text
2415105017-Undergraduate_Theses.pdf Download (6MB) | Preview |
Abstract
Untuk meningkatkan produksi energi listrik maka komponen-komponen utama Pembangkit Listrik Tenaga Gas dan Uap (PLTGU) haruslah beroperasi secara optimal. Salah satu komponen utama dari PLTGU adalah Heat Recovery Steam Generator (HRSG). HRSG memiliki beberapa komponen utama yaitu superheater, evaporator, dan economizer yang tersusun atas tube-tube yang memiliki struktur dan jumlah terterntu yang memepengaruhi performansi HRSG. Pada penelitian ini dilakukan analisa unjuk kerja HRSG dengan menggunakan pendekatan porous media. Pada penelitian ini dilakukan tiga variasi yaitu variasi satu dengan jumlah tube aktual sesuai dengan real plant HRSG yang terdapat di PLTGU – Jawa Timur dengan jumlah tube 6976 buah. Variasi kedua yaitu dengan menambahkan tube sehingga jumlah tube total menjadi 7116 buah. Variasi ketiga yaitu mengurangi jumlah tube sehingga jumlah tube total menjadi 6836 buah. Jumlah tube ini berpengaruh pada jumlah tube pada setaip komponen di HRSG. Pada variasi I suhu HRSG yang ditunjukkan oleh suhu pada HP superheater II adalah 741 K, sedangkan suhu pada variasi II adalah 745 K dan suhu pada variasi III adalah 741 K. Suhu pada variasi II lebih besar dibandingkan dengan variasi I dan II dikarenakan variasi II memiliki jumlah tube yang lebih banyak sehingga area perpindahan panas yang dimiliki variasi II lebih besar. Kecepatan aliran outlet pada variasi I adalah 3,442 m/s, variasi II 3,463 m/s dan variasi III 3,319 m/s. Variasi II memiliki kecepatan yang lebih besar dibandingkan dengan varias I dan III dikarenakan luasan bidang yang dilewati semakin kecil seiringnya dengan bertambahnya jumlah tube.
=============================================================================================================================
To increase the production of electrical energy, the main components of Gas and Steam Power Plant (PLTGU) must operate optimally. One of the main components of PLTGU is the Heat Recovery Steam Generator (HRSG). HRSG has several major components such as superheater, evaporator, and economizer that composed of tubes that have structures and quantities that affect HRSG performance. In this research, there are three variation. The first variation is with the actual number of tubes according to the real plant of HRSG in PLTGU - East Java with 6976 pieces tubes. The second variation is by adding tubes so the total tubes number becomes 7116 pieces. The third variation is reducing the number of tubes so that the total tubes becomes 6836 pieces. The number of tubes affects the number of tubes in a components of HRSG. In variation I the temperature of HRSG indicated by the temperature at HP superheater II is 741 K, whereas the temperature of the variation II is 745 K and the temperature of the variation III is 741 K. The temperature of the variation II is greater than the variations I and II due to variation II has more tubes so the heat transfer area variation II is larger than variation I and variation III. Velocity outlet in variation I was 3,442 m/s, variation II was 3,463 m/s and variation III was 3,319 m/s. Variation II has a greater velocity compared with variations II and III due to the area
Item Type: | Thesis (Other) |
---|---|
Uncontrolled Keywords: | HRSG, porous media, tube, suhu, kecepatan |
Subjects: | T Technology > TJ Mechanical engineering and machinery > TJ164 Power plants--Design and construction |
Divisions: | Faculty of Industrial Technology > Physics Engineering > 30201-(S1) Undergraduate Thesis |
Depositing User: | Nur Rima Samarotul Janah |
Date Deposited: | 13 Nov 2024 08:50 |
Last Modified: | 13 Nov 2024 08:50 |
URI: | http://repository.its.ac.id/id/eprint/47747 |
Actions (login required)
View Item |