Perancangan Automatic Transfer Switch Main Generator-Emergency Generator Di Kapal Berbasis Plc Dan Dimonitor Menggunakan Human Machine Interface (Hmi)

Waramory, Boy hendra (2016) Perancangan Automatic Transfer Switch Main Generator-Emergency Generator Di Kapal Berbasis Plc Dan Dimonitor Menggunakan Human Machine Interface (Hmi). Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[img]
Preview
Text
4213106010-Undergraduate Thesis.pdf - Published Version

Download (3MB) | Preview

Abstract

Listrik di Kapal dilayani oleh generator yang merupakan penyuplai listrik terbesar, menyediakan suplai listrik untuk peralatan listrik. Ketika terjadi pemadaman akibat adanya perawatan atau kesalahan sistem, maka akan terjadi Black Out. Kondisi Black Out adalah kondisi di mana sumber tenaga penggerak utama, permesinan bantu, dan peralatan lainnya pada kapal tidak beroperasi karena tidak adanya pasokan listrik yang disebabkan oleh kegagalan pada sistem kelistrikan. Mengatasi keadaan black out menggunakan peralatan ACOS. Peralatan ACOS yang dibuat berbasis PLC di mana apabila main generator failure maka akan automatis berpindah menuju baterai dan emergency generator. Parameter pemindahan suplai listrik berdasarkan phase failure, under voltage dan over voltage. Berdasarkan pengujian waktu pemindahan suplai listrik selama 30 detik. Terdapat sistem interlock pada setiap suplai listrik disaat proses switching untuk menghindari masuknya suplai listrik secara bersamaan. ======================================================================================================= Electricity on board is served by the generator that is the largest electricity suppliers, providing electricity to supply electrical equipment. When the black out occurred due to maintenance or system error occurs, then it will Black Out. Black Out condition is a condition in which the main source of propulsion, auxiliary machinery, and other equipment on the vessel are not in operation due to the absence of electricity supply, caused by a failure in the electrical system. Addressing the State of the black out using the equipment of ACOS. ACOS equipment made based PLC where in a main generator failure it will automatically switch towards the batteries and emergency generators. Electrical supply transfer parameters based on phase failure, under voltage and over voltage. Based on testing of the electrical supply transfer time for 30 seconds. There is an interlock system on each power supply when the switching process to avoid the inclusion of electric supply simultaneously.

Item Type: Thesis (Undergraduate)
Additional Information: RSSP 623.872 36 War p
Uncontrolled Keywords: Main generator, Emergency generator, Baterai, ACOS
Subjects: V Naval Science > VM Naval architecture. Shipbuilding. Marine engineering > VM731 Marine Engines
Divisions: Faculty of Marine Technology > Marine Engineering > (S1) Undergraduate Theses
Depositing User: Mr. Tondo Indra Nyata
Date Deposited: 07 Feb 2018 03:06
Last Modified: 27 Dec 2018 08:39
URI: http://repository.its.ac.id/id/eprint/51178