Perencanaan mengenai pembangunan backbone saluran transmisi menggunakan HVDC dengan rating tegangan penyaluran 500 kV di pulau Kalimantan merupakan upaya alternatif perencanaan saluran transmisi guna mewujudkan interkoneksi saluran transmisi yang memiliki keandalan memadai terhadap tantangan pertumbuhan beban tenaga listrik yang berkembang kedepan. Dengan backbone saluran transmisi yang andal maka akan diwujudkan keseimbangan antara jumlah total pembangkitan energi listrik yang dihasilkan di sektor hulu dan jumlah total beban yang dibutuhkan di sektor hilir. Permodelan saluran transmisi HVDC dengan konfigurasi multi terminal akan memberikan fleksibilitas pengembangan backbone saluran transmisi yang diharapkan mampu mendukung perencanaan lanjutan dari pengembangan saluran transmisi di pulau Kalimantan. Berdasarkan model multi terminal backbone saluran transmisi yang dibuat maka akan dapat disimulasikan dan dianalisa laju aliran daya dari backbone saluran transmisi yang direncanakan. Hasil analisa aliran daya yang didapat dengan metode newton raphson nantinya akan menjadi data penunjang perencanaan lanjutan dan pembangunan sistem transmisi yang dapat dipilih berdasarkan analisa aspek teknis serta aspek teoritis yang memadai.
===========================================================================================================
Planning on the construction of a transmission line backbone using HVDC with a 500 kV drain voltage rating on the island of Borneo is an alternative means of transmission line planning in order to realize a transmission line interconnect that has adequate reliability against the challenges of growing power load growth ahead. With a reliable transmission line backbone it will realize the balance between the total generation of electrical energy generated in the upstream sector and the total amount of load required in the downstream sector. Modeling HVDC transmission lines with multi-terminal configurations will provide the flexibility of developing a transmission line backbone that is expected to support the continued planning of the development of transmission channels on the island of Borneo. Based on the multi terminal model the transmission line backbone made will be able to simulate and analyze the flow rate of power from the backbone of the planned transmission line. The result of power flow analysis obtained by newton raphson method will become the supporting data of advanced planning and development of transmission system which can be chosen based on technical aspect analysis and the theoretical aspect which is adequate.

Item Type: Thesis (Undergraduate)
Additional Information: RSE 621.319 Kus p-1 3100018075744
Uncontrolled Keywords: Backbone Multi-terminal, Transmisi HVDC, Analisis Aliran Daya, Multi-terminal Backbone, HVDC Transmission, Power Flow Analysis
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK201 Electric Power Transmission
T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK1010 Electric power system stability. Electric filters, Passive.
Divisions: Faculty of Architecture, Design, and Planning > Industrial Product Design > 90231-(S1) Undergraduate Thesis
Depositing User: Kusuma I Putu Mery Teja
Date Deposited: 03 Dec 2018 05:09
Last Modified: 01 Oct 2020 03:47
URI: http://repository.its.ac.id/id/eprint/53242

Actions (login required)

View Item View Item