Abstract

Indonesia memiliki potensi untuk mengembangkan energi alternatif. Pembangkit listrik alternatif dianggap lebih ramah lingkungan jika dibandingkan dengan pembangkit listrik konvensional yang menggunakan minyak bakar dan batu bara. Energi alternatif tersebut dapat berupa solar cell dan turbin angin. Salah satu komponen penting dalam pembuatan pembngkit listrik ini adalah charge controller. Pada prinsipnya pengisian muatan baterai dilakukan dengan cara mengaliri arus listrik secara terus menerus. Sistem charging dan monitoring pada baterai level tegangan 12 volt perlu dirancang agar baterai terhindar dari penyebab kerusakan yang sering terjadi yaitu pengisian atau penggunaan baterai yang tidak terkontrol. Pada perancangan ini, sensor yang digunakan yaitu sensor tegangan sumber, pengisian, dan sensor tegangan baterai yang memiliki nilai ketidakpastian diperluas (Uexp) yaitu 1,36, 0,49, dan 0,95. Proses charging yang telah dibuat mampu mencapai tegangan 13,38 V dengan daya baterai bernilai 16.11 Watt. Sistem monitoring mampu menampilkan daya baterai dan tegangan pada charge controller.
=========================================================================================================
Indonesia has the potential to develop alternative energy. Alternative power plants are considered more environmentally friendly when compared to conventional power plants that use fuel oil and coal. Alternative energy can be solar cell and wind turbine. One important component in making this electricity generator is the charge controller. In principle, charging a battery charge is carried out by flowing electric current continuously. Charging and monitoring systems on a 12 volt battery level need to be designed so that the battery is protected from the causes of damage that often occurs, which is charging or using uncontrolled batteries. In this design, the sensors used are the source voltage, charging, and battery voltage sensors which have an extended uncertainty value (Uexp) is 1.36, 0.49 and 0.95. The charging process that has been made is able to reach a voltage of 13.38 V with a battery power of 16.11 Watt. The monitoring system is capable of displaying battery power and voltage on the charge controller.

Item Type: Thesis (Diploma)
Additional Information: RSIn 621.312 42 Day p-1 3100018076773
Uncontrolled Keywords: Baterai, Sensor Tegangan, Charge Controller, Monitoring, Battery, Voltage Divider, Charge Controller, Monitoring
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK2945 Lead-acid batteries.
Divisions: Faculty of Vocational > Instrumentation Engineering
Depositing User: Fitria Dayanti
Date Deposited: 11 Jan 2019 08:17
Last Modified: 04 Feb 2021 07:38
URI: http://repository.its.ac.id/id/eprint/58424

Actions (login required)

View Item View Item