Analisa Partial Discharge pada Isolator dengan Metode Very High Frequency

Simanungkalit, Samuel (2019) Analisa Partial Discharge pada Isolator dengan Metode Very High Frequency. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of Buku_Samuel Simanungkalit_07111440000146.pdf]
Preview
Text
Buku_Samuel Simanungkalit_07111440000146.pdf

Download (2MB) | Preview

Abstract

Partial Discharge (PD) merupakan suatu fenomena yang terjadi pada peralatan tegangan tinggi berupa peluahan sebagian sehingga menghubungkan dua elektroda terpisah. PD dapat menjadi salah satu penyebab penurunan kualitas dari peralatan tegangan tinggi seiring berjalannya waktu peralatan tersebut bekerja karena PD menghasilkan panas, arc dan karbonisasi pada peralatan. PD tidak hanya menyebabkan kerusakan pada peralatan tegangan tinggi, melainkan juga dapat memberikan gangguan pada sumber daya listriknya. Partial Discharge yang akan dibahasa berupa PD pada isolator yang baik dan isolator yang memiliki void. Partial Discharge terjadi pada bagian luar dari isolator yang baik, sedangkan pada isolator yang memiliki void, PD juga terjadi pada bagian dalam dari void tersebut. Saat ini pengujian PD masih menggunakan kopel generator, AE (Acoustic Emission) Detector dan thermografi. Tugas akhir ini membahas metode untuk mendeteksi PD pada isolator dengan cara yang lebih baik karena tidak diperlukan untuk bersentuhan langsung dengan peralatan. Pengujian yang dilakukan menggunakan metode Very High Frequency. Metode ini menggunakan antena yang berfungsi sebagai alat bantu untuk menangkap sinyal gelombang daya yang dihasilkan oleh isolator. Diharapkan dengan metode ini dapat mendeteksi PD pada isolator sebelum terjadinya breakdown voltage atau arc.
===============================================================================================================================
Partial Discharge (PD) is a phenomenon that occurs in high voltage equipment in the form of partial discharge which connects two separate electrodes.PD can be one of the causes of the deterioration quality of high voltage equipment as the time goes by the equipment works because PD produces heat, arc, and carbonization on the equipment. PD does not only cause damage to high voltage equipment, but can also provide interference to the power source. Partial Discharge which will be discussed in the form of PD in good insulator and insulator that have void. Partial Discharge occurs on the outside of a good insulator, whereas in insulator that has void, PD occurs inside of the void. Currently, PD testing is still using a coupling generator, AE (Acoustic Emission) Detector and thermography. This final project discusses method for detecting PD in insulator in a better way because it is not needed to be in direct contact with the equipment. The test were carried out using the Very High Frequency (VHF) method. This methord uses an antenna that serves as a tool to capture the wave signal generated by the insulator. It is expected that this method can.

Item Type: Thesis (Other)
Additional Information: RSE 621.319 37 Sim a-1 2019
Uncontrolled Keywords: Partial Discharge (PD), Very High Frequency (VHF), Isolator, Arus Bocor.
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK3401 Insulation and insulating materials
Divisions: Faculty of Electrical Technology > Electrical Engineering > 20201-(S1) Undergraduate Thesis
Depositing User: Samuel Simanungkalit
Date Deposited: 27 Mar 2023 01:38
Last Modified: 27 Mar 2023 01:38
URI: http://repository.its.ac.id/id/eprint/63935