Modifikasi Perencanaan Struktur Gedung Apartemen Darmo Hill Menggunakan Struktur Bangunan Baja dengan Steel Plate Shear Wall dan Concrete Filled Steel Tube

Karena, Nur Bayyiti Monica (2019) Modifikasi Perencanaan Struktur Gedung Apartemen Darmo Hill Menggunakan Struktur Bangunan Baja dengan Steel Plate Shear Wall dan Concrete Filled Steel Tube. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 03111540000046-Undergraduate_Theses.pdf]
Preview
Text
03111540000046-Undergraduate_Theses.pdf

Download (22MB) | Preview

Abstract

Indonesia merupakan daerah rawan terjadi gempa bumi, hal tersebut diakibatkan oleh adanya sebaran sesar aktif. Salah satu contoh daerah rawan gempa yaitu Surabaya, dimana bahaya gempa berasal dari sesar Barbis-Kendheng dengan pergerakan 4,5 milimeter per tahun. Salah satu bangunan gedung di Surabaya adalah Apartemen Darmo Hill yang memiliki 34 lantai, 2 basement, dan 3 podium dengan menggunakan struktur beton bertulang. Struktur beton bertulang memiliki keunggulan dalam hal bentuk, kemudahan material, serta ekonomis. Ada juga Kelemahan material beton bertulang yaitu kekuatan relatif rendah, membutuhkan bekisting, serta perubahan volume tergantung waktu. Adapun alternatif bahan studi perancangan bangunan ini menggunakan struktur baja dengan sistem geser pelat baja (Steel Plate Shear Wall) dan Kolom Concrete Filled Steel Tube (CFST). Dinding geser pelat baja (Steel Plate Shear Wall) adalah sebuah sistem penahan beban lateral yang terdiri dari dinding pelat baja, kolom dan balok lantai horizontal. Kolom Concrete Filled Steel Tube (CFST) merupakan sebuah kolom komposit yang memberikan keuntungan dari hasil penggabungan kekuatan tinggi dari daktilitas baja dengan kekuatan tekan serta kekakuan beton. Tujuan tugas akhir ini dibuat diharapkan dapat menjadi rekomendasi untuk proyek-proyek selanjutnya yang ada di Indonesia agar dapat memanfaatkan material baja sebagai bahan struktur gedung dengan pertimbangan keuntungan penggunaan material baja sebagai struktur utama gedung. Untuk perencanaan struktur baja yang rasional, perencanaan ini mengacu pada peraturan-peraturan yang berlaku diantaranya SNI 1726:2012 tentang Tata Cara Perencanaan Tahan Gempa Untuk Bangunan Gedung dan Non Gedung, SNI 1729:2015 tentang Spesifikasi untuk Bangunan Gedung Baja Struktural, PPIUG 1983 tentang Peraturan Pembebanan Indonesia Untuk Gedung, dan SNI 1727:2013 tentang Beban Minimum Untuk Perencanaan Bangunan Gedung dan Struktur Lain. Beban gempa dihitung dengan metode beban gempa dinamis respons spectrum, kemudian dianalisis dengan menggunakan program bantu komputer ETABS. Dari hasil analisa yeng telah dilakukan diperoleh hasil yaitu: tebal pelat atap 9 cm, pelat lantai 9 cm. dimensi balok induk atap WF 600x300x14x23, balok induk lantai WF 800x300x16x30, dimensi balok anak atap 400x200x7x11, dimensi balok anak lantai WF 600x200x10x15, dimensi kolom beton basement 1200x1200, dimensi kolom lantai LG,G,UG,1-7 CFT 1000x1000x25x25, dimensi kolom lantai 8-20 CFT 800x800x25x25, dimensi kolom lantai 21-33 CFT 600x600x25x25 dimensi kolom VBE CFT 800x800x25x25, dimensi HBE WF 800x300x16x30, tebal SPSW 3 mm. Shearwall basement menggunakan tebal 38 cm. Base plate menggunakan ukuran 120x120 cm. Perencanaan pondasi menggunakan tiang pancang precast diameter 80cm dengan kedalaman 28m.
===============================================================================================================================
The Indonesian region is active seismically and there are active faults making the regions of Indonesia prone to earthquakes. One of them is Java, especially Surabaya. The danger of the earthquake comes from the Barbis-Kendheng fault with a movement of 4.5 millimeters per year. One of the buildings in Surabaya is the Darmo Hill Apartment which has 33 floors, 2 basements, and 3 podiums using reinforced concrete structures. Reinforced concrete structures have the advantage of being able to use various forms, material ease, and economics. There are also disadvantages of reinforced concrete material, which is relatively low strength, requires formwork, and changes in volume depending on time. The alternative design materials for this building use steel structures with steel plate shear walls and the Concrete Filled Steel Tube column (CFST). Steel Plate Shear Wall is a lateral load restraint system consisting of steel plate walls, columns and horizontal floor beams. The Concrete Filled Steel Tube (CFST) column is a composite column that provides the advantage of combining high strength of steel ductility with compressive strength and concrete stiffness. The purpose of this final project is expected to be a recommendation for subsequent projects in Indonesia in order to be able to utilize steel material as building structure material by considering the advantages of using steel material as the main structure of the building.
For rational steel structure planning, this plan refers to applicable regulations including SNI 1726: 2012 concerning Earthquake Resistant Planning Procedures for Building and Non-Building, SNI 1729: 2015 concerning Specifications for Structural Steel Buildings, PPIUG 1983 concerning Regulations Indonesian Loading for Buildings, and SNI 1727: 2013 concerning Minimum Load for Planning Building Buildings and Other Structures. Earthquake load is calculated by dynamic earthquake load spectrum response methods, then analyzed using ETABS.
From the results of the analysis that has been done, it is found that: 9 cm thick roof plate, 9 cm floor plate. dimensions of WF 600x300x14x23 roof beam, WF 800x300x16x30 floor beam, 400x200x7x11 roof beam dimensions, WF floor beam dimensions 600x200x10x15, basement concrete column dimensions 1200x1200, floor column dimensions LG,G,UG,1-7 CFT 1000x1000x25x25, 8-20 floor column dimensions 800x800x25x25, 21-33 floor column dimensions 600x600x22x22 dimensions VBE CFT column 800x800x25x25, dimensions of HBE WF 800x300x16x30, thickness of 3 mm SPSW. Shearwall basement uses 38 cm thick. Base plate uses a size of 120x120 cm. Planning foundation using 80cm precast piles with 28m depth.

Item Type: Thesis (Other)
Uncontrolled Keywords: Modifikasi Struktur, Steel Plate Shear Wall, Kolom Concrete Filled Steel Tube
Subjects: T Technology > TH Building construction
T Technology > TH Building construction > TH1095 Earthquakes and building
Divisions: Faculty of Civil Engineering and Planning > Civil Engineering > 22201-(S1) Undergraduate Thesis
Depositing User: Nur Bayyiti Monica Karena
Date Deposited: 12 Jul 2024 03:21
Last Modified: 12 Jul 2024 03:21
URI: http://repository.its.ac.id/id/eprint/67101