Evaluasi Timbulnya Genangan Pada Catchment Area Sistem Pematusan Greges Yang Dilayani Rumah Pompa Greges di Rayon Genteng Surabaya - Evaluation On The Causes Of Flood In Drainage System In The Greges Catchment Area Which Is Served By A Greges Pumping Station At Genteng Surabaya

Putranto, Januar Catur (2016) Evaluasi Timbulnya Genangan Pada Catchment Area Sistem Pematusan Greges Yang Dilayani Rumah Pompa Greges di Rayon Genteng Surabaya - Evaluation On The Causes Of Flood In Drainage System In The Greges Catchment Area Which Is Served By A Greges Pumping Station At Genteng Surabaya. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 3312100026-Undergraduate Thesis.pdf]
Preview
Text
3312100026-Undergraduate Thesis.pdf - Published Version

Download (5MB) | Preview

Abstract

Salah satu sistem pematusan Kota Surabaya di Rayon
Genteng adalah Sistem Pematusan Greges. Sistem pematusan
Greges mencakupi sebagian besar wilayah Kecamatan
Krembangan dan beberapa bagian wilayah Kecamatan Tegalsari,
Sawahan, Asemrowo, Pabean Cantikan, dan Suko Manunggal
dengan luas total 1520 ha. Ketika musim penghujan tahun 2015,
genangan masih terdapat di 13 titik pada catcment area saluran
yang dilayani Rumah Pompa Greges dengan luas genangan total
11,83 ha, tinggi genangan maksimum 13 centimeter dan lama
genangan maksimum 110 menit.
Sistem Pematusan Greges yang dilayani oleh Rumah Pompa
Greges ini memiliki 1 saluran primer yaitu saluran primer Kali
Greges. Saluran primer Kali Greges ini memiliki panjang mencapai
4-5 km dan lebar 12-22 meter dan merupakan muara dari 17
saluran sekunder. Selain rumah pompa Greges yang melayani
saluran primer Kali Greges, terdapat 3 rumah pompa di 1 saluran
sekunder dan 2 saluran tersier yang berfungsi untuk mengalirkan
debit limpasan ke saluran primer Kali Greges yaitu rumah pompa
Dupak Bandarejo di saluran sekunder Kali Dupak, rumah pompa
Asem Jaya di saluran tersier Kali Asem Jaya, dan rumah pompa
Tidar di saluran tersier Petemon Kali yang tidak di operasikan lagi.
Diperlukan adanya evaluasi mengenai timbulnya genangan di
wilayah Sistem Pematusan Greges yang dilayani Rumah Pompa
Greges dengan menghitung kapasitas pompa, debit saluran primer, dan debit saluran sekunder untuk meninjau permasalahan
pematusan yang ada. Diharapkan dengan adanya evaluasi ini,
permasalahan genangan di catchment area Sistem Pematusan
Greges yang dilayani Rumah Pompa Greges dapat terselesaikan.
Hasil evaluasi menunjukkan bahwa kondisi eksisting 5
segmen saluran sekunder tidak mampu melayani debit limpasan
air hujan yang menyebabkan terjadinya genangan dengan luas
total genangan 5,71 ha dengan lama waktu genangan maksimum
240 menit dan tinggi genangan maksimum 40 centimeter. Dari
hasil evaluasi diketahui salah satu penyebab timbulnya genangan
yaitu adanya sedimen pada saluran dengan ketinggian bervariasi.
Selain itu, penyebab lain timbulnya genangan yaitu tidak adanya
Standard Operating Procedure (SOP) Pengoperasian Pompa
pada wilayah Sistem Pematusan Greges. Hal ini diketahui dari
salah satu hasil observasi lapangan pada tanggal 16 April 2016
bahwa terjadi persebaran genangan yang sangat luas.
Kesimpulan dari evaluasi ini yaitu dibutuhkan pengerukan
secara menyeluruh untuk mengatasi permasalahan sedimen yang
ada. Pengerukan ini perlu dilakukan pada 5 segmen saluran yaitu
Kali Dupak, Kali Demak Timur, Kali Margo Rukun, Kali Semarang,
Kali Tembok Gede karena saluran tidak mampu melayani limpasan
hujan. Selain itu, diperlukan adanya SOP Pengoperasian Pompa
yang tertulis untuk wilayah Sistem Pematusan Greges.
========================================================================================================================
One of the drainage systems in Surabaya at Genteng Rayon
is Greges drainage system. Greges drainage system serves mostly
for district of Krembangan and partially serves for district of
Tegalsari, Sawahan, Asemrowo, Pabean Cantikan, and Suko
Manunggal with a total area of 1520 ha. On the rainy season period
at 2015, there were 13 points of flood in the catchment area served
by Greges Pumping Station with 11,83 ha of extensive total flood
area, 13 centimeters of the maximum water level reached, and 110
minutes of long flood reaching period.
Greges drainage system served by Greges Pumping Station
has one primary river namely Greges Primary River. This Greges
Primary River extends about 4-5 km in length and about 12-22 m
in width, which is outlet of 17 secondary river. In addition to Greges
pumping station that serves the Greges primary river, there are 3
pumping station at 3 secondary river which serve to transfer runoff
to the Greges primary river namely Dupak Bandarejo pumping
station in Dupak secondary river, Asem Jaya pumping station in
Asem Jaya tersiery river, and Tidar pumping station in Petemon
Kali tersiery river, which is no longer in use.
There is a need for an evaluation of the ability of Greges
Pumping Station in the drainage system of Greges catchment area
to find related flood problems by calculating the capacity of the
Pumping Station, debit of Primary Canal and Secondary Canal.
Problem resolve of this analysis of the flood problems in drainage system of Greges catchment area served by Greges Pumping
Station is to be expected.
The results showed that the condition of five existing
secondary channel segments were not able to serve rainwater
discharge runoff, which caused flooding with 5.71 ha of total area,
240 minutes of maximum flood period and 40 centimeters of
maximum water level. It is known from the observation that
sediment vary in height of the channel is one to cause the flood.
Moreover, an absence of Standard Operating Procedure (SOP) to
operate the pump in the drainage system of Greges catchment
area is one other else to cause such problem. Observation in the
study case area on 16 April 2016 shows such extended flood area
from the causes.
The conclusion of this evaluation is a need of thorough
dredging for five segments of channel located in Dupak Canal,
Demak Timur Canal, Margo Rukun Canal, Semarang Canal,
Tembok Gede Canal, which is unable to serve the runoff of
rainwater caused by increasing sediment. It is also needed to
establish SOP of the Operation Pump for the Greges catchment
area drainage system.

Item Type: Thesis (Undergraduate)
Additional Information: RSL 627.54 Put e
Uncontrolled Keywords: Genangan, Rayon Genteng, Rumah Pompa Greges, Saluran Primer Kali Greges, Sistem Pematusan Greges, Flood, Genteng State, Greges Drainage System, Greges Primary River, Greges Pumping Station
Subjects: T Technology > TE Highway engineering. Roads and pavements > TE215 Drainage
Divisions: Faculty of Civil, Environmental, and Geo Engineering > Environmental Engineering
Depositing User: ansi aflacha
Date Deposited: 04 Dec 2019 02:52
Last Modified: 04 Dec 2019 02:52
URI: http://repository.its.ac.id/id/eprint/72182

Actions (login required)