Perencanaan Emergency Response Plan (ERP) Dan Penentuan Alat Pemadam Api Ringan (Apar) Pada Gedung Research Center-ITS

Hidayat, Fiqi Anwar (2015) Perencanaan Emergency Response Plan (ERP) Dan Penentuan Alat Pemadam Api Ringan (Apar) Pada Gedung Research Center-ITS. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[img]
Preview
Text
2511100039-Presentation.pdf - Presentation

Download (2MB) | Preview
[img]
Preview
Text
2511100039-Undergraduate_Theses.pdf - Accepted Version

Download (10MB) | Preview
[img]
Preview
Text
2511100039-Paper.pdf - Accepted Version

Download (2MB) | Preview

Abstract

Sistem Manajemen Keselamatan dan Kesehatan Kerja (SMK3) merupakan hal yang seharusnya diaplikasikan pada lingkungan kerja baik pada tata cara kerja maupun lingkungan tempat bekerja. Gedung Riset Centre ITS merupakan salah satu gedung baru yang ada di lingkungan kampus Institut Teknologi Sepuluh Nopember sehingga belum ada perencanaan mengenai SMK3 pada gedung tersebut. Penelitian ini bertujuan untuk memberikan perencanaan Emergency Response Plan (ERP) dan menentukan Alat Pemadam Api Ringan (APAR). Perencanaan ini diharapkan mampu memenuhi standar yang telah ditetapkan oleh pemerintah seperti UU No. 26 Tahun 2008 dsb. Penelitian ini diawali dengan pencarian data mengenai dimensi bangunan, fungsi setiap ruangan serta identifikasi fire hazard. Dari dimensi bangunan dan fungsi gedung kemudian didapatkan estimasi kapasitas gedung. Dari estimasi kapasitas gedung selanjutnya dihitung kebutuhan pintu darurat, tangga darurat dan lokasi meeting point. Sementara dari identifikasi fire hazard didapat APAR yang sesuai dengan masing-masing karakteristik fire hazard. selanjutnya dari jenis APAR yang digunakan kemudian untuk mengetahui letak pemasangan APAR yang optimal dan mampu menjangkau seluruh bangunan digunakan metode set covering. Dalam penelitian ini juga diberikan rute evakuasi dan rekomendasi pemasangan sprinkler dan smoke detector. ========== Occupational Safety and Health Management System is a proper thing that should be applied in every work environment both in work method and workplace environment. Research Centre ITS is one of the newest building in ITS environment, so there isn’t a safety management system that would be applied in this building yet. This research aiming to give an Emergency Response Plan (ERP) and fire extinguisher which is suitable to be used in this building. This research expected to make building’s safety management meet the requirement from the government such as UU No. 26 Tahun 2008 etc. this research begin with data searching about building’s dimension, main function of each room and fire hazard identification toward each room. From building’s dimension, then capacity of the building can be calculated. From calculation of building’s capacity, requirements for the emergency exit, emergency stairs, and meeting point location can be determined. Then, from fire hazard identification can be determined the type of fire extinguisher that proper to used. Furthermore using type of fire extinguisher then the optimum location of fire extinguisher’s installation that can reach every corner of the building could be determined. In this research also given evacuation route and some recommendation for sprinkler and smoke detector’s installation.

Item Type: Thesis (Undergraduate)
Additional Information: RSI 658.477 Hid p 3100016063565
Uncontrolled Keywords: Alat Pemadam Api Ringan (APAR), Emergency Response Plan (ERP), Fire Hazard, Set Covering, Alat Pemadam Api Ringan (APAR), Emergency Response Plan (ERP), Fire Hazard, Set Covering
Subjects: H Social Sciences > HD Industries. Land use. Labor > HD49 Crisis management. Emergency management
Divisions: Faculty of Architecture, Design, and Planning > Interior Design
Depositing User: - Davi Wah
Date Deposited: 09 Dec 2019 03:02
Last Modified: 09 Dec 2019 03:02
URI: http://repository.its.ac.id/id/eprint/72208

Actions (login required)

View Item View Item