Holis, Akhmad (2014) Pengendalian Kebisingan Antar Ruang Berdasarkan Transmission Loss Dan Flanking : Studi Kasus Laboratorium Komputer Dan Ruang Baca. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.
Preview |
Text
2409100018-Undergraduate_Thesis.pdf - Accepted Version Download (4MB) | Preview |
Preview |
Text
2409100018-Presentation.pdf - Presentation Download (1MB) | Preview |
Preview |
Text
2409100018-Paper.pdf - Accepted Version Download (917kB) | Preview |
Abstract
Ruang baca merupakan salah satu tempat yang
membutuhkan ketenangan dan kenyamanan supaya para
pembaca yang sedang melakukan aktivitasnya tidak merasa
terganggu. Salah satu faktor kenyamanan pada ruang baca
(studi kasus di Jurusan Teknik Fisika FTI-ITS) adalah dari
segi akustik yakni tingkat kebisingan pada ruangan tersebut
yang mana sebagian besar bersumber dari laboratorium
komputer. Padatnya aktivitas di laboratorium komputer
menjadi salah satu sumber bising pada ruang baca yang mana
bising tersebut menjalar dari laboratorium komputer ke ruang
baca melalui dinding partisi yang menhubungkan kedua
ruangan. Penelitian dilakukan dengan cara pengambilan data
tingkat tekanan bunyi pada kedua ruangan tersebut. Setiap
ruangan memiliki 6 titik pengukuran yang berjarak 1m dari
dinding partisi. Pengukuran menggunakan SLM SOLO untuk
mendapatkan tingkat tekanan bunyi pada setiap titik
pengukuran yang mana setiap titik memiliki jarak 2m antar
titik kecuali dua titik yang berdekatan dengan dinding luar
bagian selatan dan utara. Dari hasil pengukuran didapatkan
bahwa nilai noise reduction dari dinding partisi yang terbuat
dari plywood tersebut cukup kecil sehingga sebagian besar
bising dari laboratorium komputer tembus ke dalam ruang
baca. Untuk mengurangi bising yang terjadi maka dilakukan
perancangan dinding partisi double panel homogen
menggunakan material fiber cement board dan gypsum board
dengan variasi ketebalan dan jarak (cavity) antar panel. Hasil
dari perancangan dinding partisi yang paling baik adalah
gypsum board 25mm dimana rancangan tersebut memiliki
nilai insulasi tunggal (DnTw+Ctr) sebesar 36.2 dB. Sedangkan
untuk kontribusi aspek flanking terhadap bising yang terjadi
dapat dikatagorikan cukup tinggi yakni maksimal 14.9 dB
pada frekuensi 800 Hz dan pada frekuensi 160 Hz. =================================================================================== The reading room is one place that needs and comfort so
that readers who are conducting activities not feel disturbed .
One of the comfort factor in the reading room ( a case study at
the Department of Physics FTI - ITS ) is in terms of the
acoustic noise level in the room which is largely sourced from
the computer laboratory. Density of activity in the computer
laboratory to be one source of noise in the reading room
where the noise radiating from the computer laboratory to the
reading room through the partition wall that connecting the
two rooms . The study was conducted by means of data
capture sound pressure level in the second room . Each room
has a 6 point measurement within 1m of the partition wall .
Measurements using the SLM SOLO to get the sound pressure
level at each measurement point where every point has a 2m
distance between points except the two points adjacent to the
outer wall of the south and the north . From the measurement
results showed that the value of noise reduction from partition
walls made of plywood is small enough so that most of the
noise from penetrating by computer laboratory into the
reading room . To reduce the noise that occurs then the design
partition wall panel double homogeneous materials using fiber
cement board and gypsum board with variations in the
thickness and spacing ( cavity ) between panels. The best
results of the partition wall design 25mm gypsum board where
the design has a single insulation value ( DnTw + Ctr ) of 36.2
dB . As for the contribution of flanking aspect of the noise that occurs can be categorized quite high at 14.9 dB maximum at a frequency of 800 Hz and 160 Hz in frequency.
Item Type: | Thesis (Undergraduate) |
---|---|
Additional Information: | RSF 620.23 Hol p 3100014054438 |
Uncontrolled Keywords: | Bising, Transmission Loss, Dinding Partisi, Flanking Noise, Noise, Partition Walls. |
Subjects: | T Technology > TD Environmental technology. Sanitary engineering > TD892 Noise control |
Divisions: | Faculty of Industrial Technology > Physics Engineering > 30201-(S1) Undergraduate Thesis |
Depositing User: | - Davi Wah |
Date Deposited: | 16 Jan 2020 07:47 |
Last Modified: | 16 Jan 2020 07:47 |
URI: | http://repository.its.ac.id/id/eprint/72660 |
Actions (login required)
View Item |