Perilaku Kolom Beton Persegi Dengan Retrofitting E-Glass Fiber Reinforced Polymer (E-GFRP) Strap Terhadap Beban Aksial Tekan

Pinto, Dinis (2019) Perilaku Kolom Beton Persegi Dengan Retrofitting E-Glass Fiber Reinforced Polymer (E-GFRP) Strap Terhadap Beban Aksial Tekan. Masters thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 03111450020004-Master_Thesis.pdf]
Preview
Text
03111450020004-Master_Thesis.pdf

Download (12MB) | Preview

Abstract

Struktur beton yang sering kita jumpai banyak yang mengalami kerusakan. disebabkan oleh kualitas bahan yang tidak memenuhi spesifikasi, pembebanan yang berlebih, kriteria perencanaannya yang tidak sesuai dengan standar, perubahan fungsi bangunan ataupun disebabkan oleh bencana alam seperti gempa bumi. Salah satu upaya yang dilakukan untuk meningkatkan kemampuan suatu struktur beton bertulang dalam memikul beban adalah dengan meningkatkan kekuatan dan daktilitas struktur tersebut dengan menggunakan metode E-Glass Fiber Reinforced Polymer (E-GFRP) Jacketing. Metode Jacketing E-Glass Fiber Reinforced Polymer (E-GFRP) penuh (full wrap) merupakan suatu metode perkuatan yang mampu memberikan kekuatan tambahan guna meningkatkan kekuatan dan daktilitas kolom. Pemakaian metode jacketing E-GFRP penuh (full wrap) telah banyak dikenal dalam perkuatan kolom beton, namun demikian, pemakaian dengan membungkus secara penuh (full wrap) bisa jadi terlalu berlebihan dibandingkan dengan kebutuhannya. Oleh karena itu tujuan penelitian ini adalah untuk mengetahui pengaruh E-GFRP straps sebagai eksternal dalam perilaku aksial tekan kolom beton persegi perkuatan dengan meningkatkan spasi strap yang bervariasi.
=================================================================================================================================
Concrete structures are very vulnerable to seismic hazard. Damages to these structures could be caused by the poor quality of materials used that do not meet the specifications, or due to excessive overloading, lack of planning criteria which do not conform with the standards, changes in the function of the building or caused by natural disasters such as earthquakes. One of the efforts made to improve the capability of a reinforced concrete structure is to increase the strength and ductility of the members using Glass Fiber Reinforced Polymer (GFRP) Jacketing. The use of full-wrapped GFRP jacketing as an alternative of retrofitting methods could be uneconomical in some cases. Hence the aim of the study is to investigate the effects of GFRP straps as external retrofit in improving the axial behavior of square concrete columns. The variation studied includes the number of layers, width, and spacing of the straps.

Item Type: Thesis (Masters)
Additional Information: RTS 624.177 25 Pin p-1
Uncontrolled Keywords: Kolom beton, pengekang, gempa bumi, retrofit eksternal, E-GFRP strap.
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
T Technology > TA Engineering (General). Civil engineering (General) > TA418.38 Materials--Fatigue.
T Technology > TA Engineering (General). Civil engineering (General) > TA660.C6 Columns
Divisions: Faculty of Civil, Planning, and Geo Engineering (CIVPLAN) > Civil Engineering > 22101-(S2) Master Thesis
Depositing User: Dinis Pihito
Date Deposited: 11 Jul 2024 01:40
Last Modified: 11 Jul 2024 01:40
URI: http://repository.its.ac.id/id/eprint/74352

Actions (login required)

View Item View Item