Analisa Karakterisasi Bolus Berbahan Silicone Rubber, Play-Doh dan Lilin Malam untuk Terapi Radiasi Menggunakan Energi Elektron

Nazara, Trimawarti (2020) Analisa Karakterisasi Bolus Berbahan Silicone Rubber, Play-Doh dan Lilin Malam untuk Terapi Radiasi Menggunakan Energi Elektron. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 01111540007001-Undergraduate_Theses.pdf]
Preview
Text
01111540007001-Undergraduate_Theses.pdf

Download (1MB) | Preview

Abstract

Penggunaan bolus dalam radioterapi sebagai material yang mempunyai sifat mirip dengan jaringan tubuh manusia adalah untuk meningkatkan dosis permukaan dan sebagai pengganti jaringan kulit yang tidak rata. Pada penelitian ini dibuat bolus dari campuran Silicone Rubber (SR) dan aluminium, Play-doh (PD) dan bolus Lilin malam (LM). Tujuan dari penelitian ini adalah untuk mendapatkan nilai densitas, dosis serap, faktor transmisi, koefisien atenuasi, kurva PDD dan dosis permukaan. CT Simulator dan Treatment Planning System (TPS) digunakan untuk analisis densitas, sementara uji dosimetri digunakan Linear Acceleration (LINAC). Semua alat uji berada di rumah sakit MRCC Siloam Semanggi Jakarta. Penelitian ini menggunakan energi elektron 6, 9 dan 12 MeV dengan ketebalan bolus bervariasi 0,5; 1 dan 1,5 cm serta luas 11×11 cm2. Hasil yang diperoleh menunjukkan bolus SR memiliki nilai densitas yang mirip dengan bolus LM dan PD yakni setara dengan densitas air. Sementara itu, pada ketebalan 1 dan 1,5 cm, bolus SR mampu menyerap energi elektron seperti bolus klinis (LM dan PD). Dapat disimpulkan bahwa bolus SR berpotensi sebagai bolus klinis karena memiliki kepadatan yang mirip dengan kerapatan air dan dapat meningkatkan dosis permukaan.
===============================================================================================================================
One of the benefits of using bolus in radiotherapy as a material that has properties similar to human body tissue is to increase surface doses and as a substitute for uneven skin tissue. In this study, boluses were made from a mixture of Silicone Rubber (SR) and aluminum, Play-doh (PD), and wax candles (LM). The purpose of this study is to obtain the value of density, absorbency dose, transmission factor, attenuation coefficient, PDD curve, and surface dose. CT Simulator and Treatment Planning System (TPS) are used as a density analysis, while the dosimetry test is used Linear Acceleration (LINAC. All test equipment is located at MRCCC Siloam Hospitals Semanggi in Jakarta. This study uses 6, 9, and 12 MeV electron energy with varying bolus thicknesses. 0.5, 1 and 1.5 cm and area 11 × 11 cm2. The results showed that the SR bolus has a density value similar to boluses of LM and PD, which is equivalent to the density of water. Meanwhile, at thicknesses of 1 and 1.5 cm, SR bolus can absorb electron energy such as clinical bolus (LM and PD). It can be concluded that SR bolus has potential as a clinical bolus because it has a density similar to water density and can increase the surface dose.

Item Type: Thesis (Other)
Additional Information: RSFi 539.2 Naz a-1 2020
Uncontrolled Keywords: Bolus, Lilin Malam, Play-Doh, Silicone Rubber
Subjects: Q Science > QC Physics > QC585.75.S55 Silica
Divisions: Faculty of Science and Data Analytics (SCIENTICS) > Physics > 45201-(S1) Undergraduate Thesis
Depositing User: Trimawarti Nazara
Date Deposited: 14 Mar 2023 03:28
Last Modified: 14 Mar 2023 03:28
URI: http://repository.its.ac.id/id/eprint/74444