Yudhistira, Dimas (2020) Evaluasi Dan Desain Perkuatan Struktur Akibat Rencana Penambahan Tangki Air Beton Di Lantai Atap Pada Gedung Waskita Rajawali Tower, Cawang, Jakarta Timur. Other thesis, Institut Teknologi Sepuluh Nopember.
Preview |
Text
10111510000031-Undergraduate_Thesis.pdf - Accepted Version Download (51MB) | Preview |
Abstract
Roof Tank atau Tangki Air yang diletakkan di bagian atap bangunan berfungsi sebagai penyuplai air yang didistribusikan secara gravitasi, tangki air rencana ini mempunyai volume kapasitas sebesar 896 m3, karena posisinya berada di permukaan tertinggi dari sebuah struktur bangunan tentunya akan menimbulkan beban tambahan dari struktur eksisting tersebut, dengan berat jenis air yang mencapai 1.000 kg/m3 dan tekanan kritis sebesar 217 atm, tentunya perlu diperhatikan kembali bagaimana kekuatan struktur bangunan eksisting sebelum dilakukan rencana penambahan tangki air tersebut agar tidak terjadi kegagalan struktur. Untuk itu pada proposal tugas akhir ini penulis mensimulasikan bagaimana analisa struktur eksisting ketika ditambah beban tambahan berupa air sesuai dengan desain tangki air yang direncanakan, kemudian direncanakan perkuatan yang mendukung akibat adanya pertambahan beban tersebut. Pada proses evaluasi struktur atas dan pondasi akan dilakukan permodelan awal gedung perkantoran (kondisi eksisting) dengan tambahan rencana tangki air beton yang kemudian akan dievaluasi menggunakan program bantu ETABS dan SAP2000, lalu akan dievaluasi menggunakan perhitungan manual dengan menggunakan standarisasi SNI 2847-2013 tentang standarisasi beton bertulang untuk bangunan gedung, untuk beban rencana yang digunakan pada tugas akhir ini akan mengacu pada standarisasi SNI 1727-2013 tentang Standard Pembebanan untuk Bangunan Gedung dan SNI 1726-2012 tentang Tata Cara Perencanaan Ketahanan Gempa Untuk Struktur Bangunan Gedung dan Non Gedung dengan peta gempa terbaru tahun 2017. Untuk desain perkuatan yang direncanakan penulis akan digunakan perkuatan metode Concrete Jacketing sesuai dengan standarisasi IS 151988:2013 dan standard jurnal yang menjelaskan tentang Concrete Jacketing tentang evaluasi dan perkuatan akibat gempa dan perkuatan menggunakan CRFP sesuai dengan standarisasi ACI 440-2R:17 tentang standard perencanaan menggunakan CRFP untuk beton bertulang. Setelah perhitungan selesai juga akan dibuat gambar kerja beserta Rencana Anggaran Biaya (RAB) dan metode pelaksanaannya. Setelah dilakukan perencanaan dengan analisa dan perhitungan, akibat penambahan rencana penambahan tangki air beton di lantai atap, terdapat perkuatan balok menggunakan CFRP pada lantai Ground Floor dan lantai 2 – lantai 16, terdapat juga perkuatan Concrete Jacketing pada pelat S4 pada area tangki. Total anggaran biaya sebesar Rp. Rp6.280.360.980,- dengan durasi pelaksaan selama 30 hari kerja.
=================================================================================================================================
Roof Tank or Water Tank placed in rooftop floor for supplying water that vertically distrubted, the water tank plan’s capacity was 896 m3 , because of the position on the top surface of the building’s structure of course causing additional loads for the existing structure. With the spesific gravity of the water itself is 1.000 kg/m3 wit the critical pressure is 217 atm, of course the capacity of the existing structure strength need to be considered again before the additional concrete tank’s plan done so that there won’t be any structural failure. For those reason, in this thesis the simulates how the analysis of the existing structure when added with additional load in the form of water in accordance with the planned water tank design, then planned reinforcement that supports due to the added load. In the process of evaluating of the top structure and foundation will be carried out existing modeling of office buildings
(existing conditions) with the additional concrete water tank model using the ETABS and SAP2000 program, and then the result will be re-evaluated with the manual calculation refering to SNI 2847- 2013 “Standarization of Reinforced Concrete for Buildings”, the load used in this thesis will refer to the SNI 1727-2013 : “Standardization of the Loading Standards for Buildings” and SNI 1726-2012 : “Concerning Earthquake Resilience Planning Procedures for Building and Non-Building Structures” with the latest 2017 earthquake map. And for the retrofitting (structure strengthening) of the existing structure, the author will use the reinforced Concrete Jacketing method in accordance with IS 151988: 2013 “Standardization Regarding Earthquake Evaluation and Retrofitting” and applicable journal on concrete jacketing, for the CRFP retrofitting calculation refering to ACI 440-2R:17: “Standardization About Retrofiting Standards Using CRFP for
Reinforced Concrete”. After the calculation is complete, a working drawing and a budget cost plan (RAB) and the method of work will be made. After planning with analysis and calculation process done, due to the addition of plans to add a concrete water tank on the rooftop floor, there is some beam reinforcement using CFRP on the Ground Floor and Floor 2 - 16th floor, there is also a reinforced Concrete Jacketing on the S4 plate in the tank area . The total budget is Rp. 14,844,863,901.36 with duration of implementation for 30 working days.
Item Type: | Thesis (Other) |
---|---|
Additional Information: | RSIS 624.177 25 Gar e-1 |
Uncontrolled Keywords: | CFRP, Evaluasi, Jacketing, Tangki |
Subjects: | T Technology > TA Engineering (General). Civil engineering (General) > TA169.5 Failure analysis T Technology > TA Engineering (General). Civil engineering (General) > TA418.9 Composite materials. Laminated materials. T Technology > TA Engineering (General). Civil engineering (General) > TA444 Reinforced concrete T Technology > TA Engineering (General). Civil engineering (General) > TA645 Structural analysis (Engineering) T Technology > TA Engineering (General). Civil engineering (General) > TA775 Foundations. |
Divisions: | Faculty of Civil Engineering and Planning > Civil Engineering > 22301-(D4) Diploma 4 |
Depositing User: | Dimas Yudhistira Gardiarsyah |
Date Deposited: | 21 Mar 2025 01:54 |
Last Modified: | 21 Mar 2025 01:54 |
URI: | http://repository.its.ac.id/id/eprint/74505 |