Transformator adalah peralatan listrik yang menggunakan dua jenis isolasi, yaitu minyak mineral dan isolasi kertas. Isolasi kertas berfungsi sebagai isolasi inter-lilitan pada bagian kumparan transformator. Sedangkan minyak mineral merupakan jenis bahan isolasi yang memiliki kekuatan dielektrik relatif tinggi. Minyak mineral berfungsi sebagai isolasi dan pendingin. Namun kekuatan dielektrik minyak mineral dapat mengalami degrdasi yang disebabkan oleh partikel selulosa yang berasal dari kertas isolasi pada transformator. Pada penelitian ini dilakukan pengujian tegangan tembus untuk mengetahui pengaruh kontaminasi partikel selulosa terhadap karakteristik elektris minyak mineral pada tegangan AC dengan peningkatan kecepatan aliran sirkulasi. Variasi sampel dilakukan pada perbedaan konsentrasi pada kontaminan partikel selulosa. Pengujian tegangan tembus dilakukan untuk mengetahui kekuatan dielektrik minyak mineral terkontaminasi partikel selulosa. Pengujian per-sampel dilakukan sebanyak 20 kali dengan menaikkan tegangan suplai secara bertahap hingga terjadi kegagalan pada isolasi. Hasil menunjukan bahwa semakin banyak jumlah kontaminan partikel selulosa, maka nilai tegangan tembus yang terukur akan semakin kecil. Kemudian dengan penambahan kecepatan aliran sirkulasi dapat menaikan nilai tegangan tembus dari minyak mineral yang terkontaminasi dengan partikel selulosa. Hal ini menunjukkan bahwa dengan adanya aliran sirkulasi akan memperlambat proses kegagalan isolasi dari minyak mineral. Berdasarkan hasil penelitian ini, dapat disimpulkan bahwa dengan adanya aliran sirkulasi pada minyak mineral akan menaikkan nilai tegangan tembus minyak mineral, akan tetapi penambahan kontaminasi partikel selulosa dapat menurunkan karakteristik tegangan tembus minyak mineral pada tegangan AC
=====================================================================================================================================
Transformers are electrical equipment that uses two types of insulation, namely mineral oil and paper insulation. Paper insulation serves as inter-winding insulation on the coil part of the transformer. Meanwhile, mineral oil is a type of insulating material that has a relatively high dielectric strength. Mineral oil can function as insulation and coolant. However, the dielectric strength of mineral oil will experience degradation caused by cellulose particles derived from insulating paper on the transformer. In this study, a breakdown voltage test was conducted to determine the effect of cellulose particle contamination on the electrical characteristics of mineral oil at AC voltage with an increase in circulation flow velocity. Sample variations were carried out on different concentrations of cellulose particle contaminants. The breakdown voltage test was conducted to determine the dielectric strength of mineral oil contaminated with cellulose particles. Per-sample testing was carried out 20 times by gradually increasing the supply voltage until insulation failure occurred. The results show that the greater the amount of cellulose particle contaminants, the smaller the measured breakdown voltage. Then with the addition of circulation flow velocity can increase the breakdown voltage value of mineral oil contaminated with cellulose particles. This shows that the presence of circulating flow will slow down the process of insulation failure of mineral oil. Based on the results of this study, it can be concluded that the presence of circulating flow in mineral oil will increase the value of the breakdown voltage of mineral oil, but the addition of cellulose particle contamination can reduce the breakdown voltage characteristics of mineral oil at AC voltage.
Item Type: | Thesis (Masters) |
---|---|
Uncontrolled Keywords: | Kecepatan Aliran, Minyak Isolasi, Partikel Selulosa, Tegangan Tembus, Tegangan AC, AC voltage, Breakdown voltage, Cellulose particles, Flow velocity, Insulating oil |
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK2551 Electric transformers. T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK3401 Insulation and insulating materials |
Divisions: | Faculty of Intelligent Electrical and Informatics Technology (ELECTICS) > Electrical Engineering > 20201-(S1) Undergraduate Thesis |