Furnace pada PLTU merupakan komponen vital dalam pembangkitan energi melalui pembakaran batu bara, namun memiliki risiko signifikan seperti ledakan, kebakaran, dan kebocoran gas yang dapat mengganggu keselamatan dan operasional. Penelitian ini menggunakan metode HAZOP untuk menganalisis bahaya pada empat node utama, yaitu Fuel Supply System, Air Supply System, Burner System, dan Control and Monitoring System. Hasilnya menunjukkan bahwa 20% komponen memiliki risiko ekstrem. Rekomendasi mitigasi untuk komponen ekstrem meliputi pemasangan check valve, monitoring otomatis, dan inspeksi berkala pada 50HFE20AN001/PA FAN "B", pemasangan sensor suhu dan alarm pada 50HFE33AA001/PULV C, serta pemeliharaan damper udara dingin dan alarm aliran pada 50HFE41AA001/PULV A. Selain itu, penerapan Emergency response plan (ERP), yang mencakup pelatihan karyawan, simulasi kebakaran, serta prosedur evakuasi dan pemadaman api secara terstruktur, diperlukan untuk meminimalkan dampak darurat dan menjamin keselamatan pekerja serta keberlanjutan operasional furnace.
==================================================================================================================================
Furnace in PLTU is a vital component in energy generation through coal Combustion, but has significant risks such as explosion, fire, and gas leakage that can interfere with safety and
operations. This research uses the HAZOP method to analyze hazards in four main nodes, namely Fuel Supply System, Air Supply System, Burner System, and Control and Monitoring
System. The results show that 20% of the components have Extreme risks. Rare recommendations for Extreme components include the installation of check valves, automatic monitoring, and periodic inspections on 50HFE20AN001/PA FAN “B”, installation of temperature sensors and alarms on 50HFE33AA001/PULV C, and maintenance of cold Air dampers and flow alarms on 50HFE41AA001/PULV A. In addition, the implementation of an Emergency response plan (ERP), which includes employee training, fire simulations, and structured evacuation and fire-fighting procedures, is needed to minimize the impact of emergencies and ensure worker safety and the sustainability of furnace operations

Item Type: Thesis (Other)
Uncontrolled Keywords: Furnace, HAZOP, Manajemen Risiko, Emergency response plan (ERP)
Subjects: T Technology > T Technology (General) > T174.5 Technology--Risk assessment.
T Technology > T Technology (General) > T55.3.H3 Hazardous substances--Safety measures.
Divisions: Faculty of Industrial Technology and Systems Engineering (INDSYS) > Physics Engineering > 30201-(S1) Undergraduate Thesis
Depositing User: Yola Marlyn Napitupulu
Date Deposited: 02 Feb 2025 07:45
Last Modified: 02 Feb 2025 07:45
URI: http://repository.its.ac.id/id/eprint/117712

Actions (login required)

View Item View Item