Pengaruh Deviasi Isocenter Terhadap Hasil Distribusi Dosis Pada Kanker Payudara Kiri Menggunakan Teknik Volumetric Modulated Arc Therapy (VMAT)

Sukarno, Hamzah Rahman (2025) Pengaruh Deviasi Isocenter Terhadap Hasil Distribusi Dosis Pada Kanker Payudara Kiri Menggunakan Teknik Volumetric Modulated Arc Therapy (VMAT). Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 5001211117-Undergraduate_Thesis.pdf] Text
5001211117-Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only

Download (11MB) | Request a copy
[thumbnail of 5001211117-Surat_Permohonan.pdf] Text
5001211117-Surat_Permohonan.pdf
Restricted to Repository staff only

Download (407kB) | Request a copy

Abstract

Penelitian ini bertujuan untuk mengevaluasi dampak pergeseran isocenter terhadap distribusi dosis pada kanker payudara kiri menggunakan teknik Volumetric Modulated Arc Therapy (VMAT). Dalam radioterapi, penentuan posisi isocenter yang akurat sangat penting untuk memastikan dosis yang optimal pada target Planning Target Volume (PTV) sekaligus meminimalkan dosis pada organ di sekitar yang berisiko Organ-at-Risk(OAR). Studi ini menggunakan fantom antropomorfik berbahan Polylactic Acid (PLA) yang dirancang menyerupai anatomi tubuh manusia. Verifikasi dosimetri dilakukan menggunakan film Gafchromic EBT4, yang dikalibrasi dengan scanner Epson V850 dan dianalisis menggunakan perangkat lunak ImageJ.Distribusi dosis dianalisis melalui Dose Volume Histogram (DVH), dengan variasi pergeseran isocenter sebesar 2 dan 4 cm ke arah lateral. Hasil menunjukkan bahwa pergeseran isocenter mepengaruhi distribusi dosis pada PTV dan OAR secara signifikan. Pergeseran sebesar 2 cm dan 4 cm menyebabkan peningkatan dosis pada jantung dan paru-paru kiri masing-masing sebesar rata-rata 8,5% dan 6,2%, dibandingkan dengan posisi isocenter optimal. Sebaliknya, distribusi dosis pada PTV menunjukkan penurunan keakuratan sebesar 7,3%. Hasil ini menekankan bahwa kesalahan dalam penentuan posisi isocenter dapat meningkatkan risiko paparan dosis pada jaringan sehat, terutama pada organ vital seperti jantung dan paru-paru.Film Gafchromic EBT4 yang digunakan menunjukkan sensitivitas tinggi pada kanal merah, dengan nilai R² sebesar 0,9987, membuktikan keandalan alat ini dalam mengukur perubahan dosis akibat variasi posisi isocenter. Temuan ini menggarisbawahi pentingnya validasi dosimetri dan verifikasi posisi isocenter dalam perencanaan dan pelaksanaan radioterapi. Penelitian ini memberikan kontribusi penting dalam optimalisasi teknik VMAT untuk aplikasi klinis, serta menjadi acuan dalam meningkatkan akurasi sistem perencanaan perawatan radioterapi di masa depan.
===================================================================================================================================
This study aimed to evaluate the impact of isocenter shift on dose distribution in left breast cancer using the Volumetric Modulated Arc Therapy (VMAT) technique. In radiotherapy, accurate isocenter positioning is crucial to ensure an optimal dose to the Planning Target Volume (PTV) while minimizing the dose to surrounding organs at risk (Organ-at-Risk (OAR)). This study used an anthropomorphic phantom made of Polylactic Acid (PLA) designed to resemble human anatomy. Dosimetric verification was performed using a Gafchromic EBT4 film calibrated with an Epson V850 scanner and analyzed using ImageJ software. Dose distribution was analyzed using a Dose Volume Histogram (DVH), with variations in the isocenter shift of 2 and 4 cm laterally. The results showed that the isocenter shift significantly affected the dose distribution of the PTV and OAR. A shift of 2 and 4 cm caused an average increase in the dose to the heart and left lung by 8.5% and 6.2%, respectively, compared to the optimal isocenter position. In contrast, the dose distribution in the PTV showed a 7.3% decrease in the accuracy. These results emphasize that errors in determining the isocenter position can increase the risk of dose exposure to healthy tissues, especially vital organs such as the heart and lungs. The Gafchromic EBT4 film used showed high sensitivity in the red channel, with an R² value of 0.9987, proving the reliability of this tool for measuring dose changes owing to variations in the isocenter position. These findings underscore the importance of dosimetric validation and isocenter position verification in radiotherapy planning and implementation. This study provides an important contribution to optimizing the VMAT technique for clinical applications and serves as a reference for improving the accuracy of radiotherapy treatment planning systems in the future

Item Type: Thesis (Other)
Uncontrolled Keywords: Gafchromic EBT4,Isocenter,Kanker payudara,VMAT,Gafchromic EBT4, isocenter, breast cancer,VMAT
Subjects: Q Science > QC Physics > QC795.5 Radioactivity and radioactive Instruments and apparatus (General)
Divisions: Faculty of Science and Data Analytics (SCIENTICS) > Physics > 45201-(S1) Undergraduate Thesis
Depositing User: Hamzah Rahman Sukarno
Date Deposited: 23 Jul 2025 00:56
Last Modified: 23 Jul 2025 01:28