Pengukuran Dosis Perawatan Radioterapi 3D-CRT Kasus Kanker Payudara Pasca–Mastektomi Menggunakan Simulasi Geant4

Firdaus, Zulvan Avivi Akmal (2022) Pengukuran Dosis Perawatan Radioterapi 3D-CRT Kasus Kanker Payudara Pasca–Mastektomi Menggunakan Simulasi Geant4. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 01111840000042-Undergraduate_Thesis.pdf] Text
01111840000042-Undergraduate_Thesis.pdf
Restricted to Repository staff only

Download (1MB) | Request a copy

Abstract

Kanker payudara merupakan salah satu jenis kanker dengan jumlah penderita paling tinggi. Radioterapi yang datang sebagai salah satu solusi bagi kanker payudara, ternyata juga memiliki berbagai efek samping yang berbahaya apabila penggunaannya tidak diperhatikan dengan benar. Berbagai metode dan teknik telah dikembangkan untuk meminimalisir efek samping buruk dari radioterapi ini. Penelitian ini bertujuan untuk memodelkan Linac Accelerator (LINAC) pada perangkat lunak berbasis open source yaitu GEANT4, serta melakukan verifikasi dosis hasil simulasi tersebut dengan simulasi pada Treatment Planning System (TPS) dan pengukuran secara langsung. Penelitian dilakukan dengan memodelkan LINAC Varian CLINAC iX pada GEANT4 dan membandingkan secara langsung hasil pengukuran dosis serap pada beberapa titik pengamatan menggunakan dosimeter Thermoluminescent Dosimeter (TLD), simulasi pada TPS dan simulasi pada GEANT4. Pemodelan LINAC pada GEANT4 menunjukkan underdose sebesar -2,90% terhadap grafik Percentage Depth Dose (PDD) LINAC riil dengan parameter flatness serta symmetry sebesar 0,71 dan 0,46% pada kedalaman 1,6 cm serta 2,65 dan 1,93% pada kedalaman 10 cm. Simulasi radioterapi menunjukkan nilai error rata - rata antara TLD dan simulasi sebesar 24,80%, sementara untuk nilai error rata - rata antara TPS dan simulasi sebesar 56,81%. Selain itu, ditampilkan juga sebaran dosis dalam bentuk heatmap yang menunjukkan kemiripan distribusi dosis pada phantom antara simulasi dengan TPS.
=================================================================================================================================
Breast cancer has been one of the deadliest cancer, with the highest amount of sufferers among other cancers. Radiotherapy came as one of the solutions for breast cancer. Despite its effectiveness in treating breast cancer, radiotherapy brings many side effects that, if not observed, could be harmful to the patient. Many methods and techniques have been developed to minimalize these side effects, and some use the algorithm in the computational calculation to simulate the radiotherapy and evaluate the result. In this research, we developed a Linear Accelerator (LINAC) model in a particle physics open-source app, GEANT4, and verified its result in radiotherapy. The simulation of LINAC was made based on Varian Clinac iX and using Thermoluminescent Dosimeter (TLD) chip as its dosimeter. The result shows that the GEANT4 LINAC model has an underdose of -2.90 % relative difference from real LINAC in terms of Percentage Depth Dose (PDD). Flatness and symmetry at 1.6 cm depth are 0.71 and 0.46 %, meanwhile at 10 cm depth their values are 2.65 and 1.93%. For the radiotherapy result, the dose distribution in the heatmap shows the similarity between the one generated by Treatment Planning System (TPS) and the GEANT4. The comparison from the point dose shows that TPS and GEANT4 have a 56.81% relative error, and real measurement and GEANT4 show a 24.80 % relative error.

Item Type: Thesis (Other)
Uncontrolled Keywords: GEANT4, Monte Carlo, Radioterapi, Treatment Planning System, Radiotherapy,
Subjects: Q Science > QC Physics
Divisions: Faculty of Science and Data Analytics (SCIENTICS) > Physics > 45201-(S1) Undergraduate Thesis
Depositing User: Mr. Marsudiyana -
Date Deposited: 09 Oct 2025 05:46
Last Modified: 09 Oct 2025 05:46
URI: http://repository.its.ac.id/id/eprint/128536

Actions (login required)

View Item View Item