Modifikasi Perencanaan Struktur Gedung Instalasi Rawat Jalan Rumah Sakit Rkz Surabaya Menggunakan Baja-Beton Komposit Dengan Sistem Eccentrically Braced Frames (EBFs)

Widiansa, Naufal Harist (2022) Modifikasi Perencanaan Struktur Gedung Instalasi Rawat Jalan Rumah Sakit Rkz Surabaya Menggunakan Baja-Beton Komposit Dengan Sistem Eccentrically Braced Frames (EBFs). Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 03111840000027-Undregraduate_thesis.pdf] Text
03111840000027-Undregraduate_thesis.pdf
Restricted to Repository staff only

Download (24MB) | Request a copy

Abstract

Kota Surabaya merupakan salah satu kota yang menjadi pusat kegiatan ekonomi masyarakat dengan kepadatan penduduk yang tinggi. Diperlukan pembangunan gedung-gedung tinggi untuk mencukupi kebutuhan masyarakat dengan memanfaatkan lahan yang terbatas. Disisi lain, Surabaya merupakan daerah rawan gempa. Oleh sebab itu, bangunan-bangunan yang ada di Kota Surabaya, khususnya bangunan tinggi, harus dirancang untuk dapat menahan beban gempa. Salah satu sistem struktur bangunan baja yang biasa digunakan untuk menahan gempa adalah sistem struktur rangka bresing eksentrik atau lebih dikenal dengan Eccentrically Braced Frames (EBFs). Sistem EBFs merupakan konsep desain gabungan antara konsep daktilitas dan disipasi energi yang baik. Konfigurasi Inverted V dipilih karena memiliki geometri yang simetris dan penempatan link yang berada di tengah bentang balok sehingga menghindari terjadinya sendi plastis di dekat kolom. Selain dari pemilihan sistem struktur, material yang digunakan juga mempengaruhi kemampuan struktur menahan beban. Material komposit dipilih karena menggabungkan dua material sehingga menghasilkan sifat gabungan yang lebih baik dan ekonomis. Dalam tugas akhir ini, Struktur Gedung Instalasi Rawat Jalan Rumah Sakit RKZ Surabaya dimodifikasi menjadi menggunakan struktur baja sistem EBFs yang memiliki 20 lantai. Konfigurasi EBFs menggunakan inverted V Brace dan akan memenuhi persyaratan keamanan struktur berdasarkan SNI 1729:2020, SNI 1726:2019, SNI 2847:2019, SNI 1727:2020, dan AISC 341-10. Dari hasil perhitungan dan analisa yang telah dilakukan, diperoleh hasil perencanaan tebal pelat lantai adalah 11 cm dengan material beton, dimensi balok induk adalah WF 600.200.12.20, WF 600.200.11.17, dan WF 600.200.10.15. Dimensi kolom menggunakan CFT (Concrete Filled Tube) 700.700.28, CFT 600.600.25, CFT 550.550.25, dan CFT 500.500.25. Struktur diperkaku dengan EBF dengan panjang link 100 cm (Short Link) dan bracing berdimensi WF 300.300.15.15. Kolom pedestal direncanakan dengan kolom beton berdimensi 1,25 x 1,25 x 1 m dan 0,8 x 0,8 x 1 m. dimensi sloof digunakan 450 x 600 mm. Pondasi direncanakan menggunakan spun pile D80 dengan kedalaman 22,5 m atau kedalaman 19 m.
====================================================================================================================================================================================
The city of Surabaya is one of the cities that is the center of economic activity of the community with a high population density. It is necessary to build high-rise buildings to meet the needs of the community by utilizing limited land. On the other hand, Surabaya is an earthquake-prone area. Therefore, buildings in the city of Surabaya, especially high-rise buildings, must be designed to be able to withstand earthquake loads. One of the structural systems of steel buildings commonly used to withstand earthquakes is the Eccentrically Braced Frames (EBFs). The EBFs system is a combined design concept between the concepts of ductility and good energy dissipation. The Inverted V configuration was chosen because it has a symmetrical geometry and the placement of the link in the middle of the beam span so as to avoid the occurrence of plastic hinges near the column. Apart from the structure selection system, the material used also affects the ability of the structure to withstand loads. Composite materials are chosen because they combine two materials to produce a better and more economical combination. In this final project, the structure of the Outpatient Installation Building of RKZ Hospital Surabaya uses a steel structure system EBFs which has 20 floors. The EBF configuration uses an inverted V Brace and will meet the structural requirements based on SNI 1729:2020, SNI 1726:2019, SNI 2847:2019, SNI 1727:2020, and AISC 341-10. From the results of calculations and analyzes that have been carried out, the results of the design for the thickness of the floor slab are 11 cm with concrete material, the dimensions of the main beam are WF 600.200.12.20, WF 600.200.11.17, and WF 600.200.10.15. Column dimensions using CFT (Concrete Filled Tube) 700.700.28, CFT 600.600.25, CFT 550.550.25, and CFT 500.500.25. The structure is stiffened with EBF with a link length of 100 cm (Short Link) and bracing with dimensions of WF 300.300.15.15. The base column is designed with a concrete column with dimensions of 1.25 x 1.25 x 1 m and 0,8 x 0,8 x 1 m. The dimension of the sloof used are 450 x 600 mm. The foundation is designed to use spun pile D80 with a depth of 22.5 m or a depth of 19 m.

Item Type: Thesis (Other)
Uncontrolled Keywords: Eccentrically Braced Frame, Link, Komposit, Inverted-V, Brace, Eccentrically Braced Frame, Link, Composite, Inverted-V, Brace
Subjects: T Technology > TA Engineering (General). Civil engineering (General) > TA681 Concrete construction
Divisions: Faculty of Civil, Planning, and Geo Engineering (CIVPLAN) > Civil Engineering > 22201-(S1) Undergraduate Thesis